Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | RGO - Revista Gaúcha de Odontologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372014000200117 |
Resumo: | OBJECTIVE: To evaluate the shear bond strength of brackets bonded to ceramic with Transbond XT resin, etching time intervals (1 and 2 minutes) and three Light sources (Xenon Plasma Arc, LED and Halogen Light ), with and without silane. METHODS: In total, 12 feldspathic ceramic cylinders (15 mm x 20 mm), etched with 10% hydrofluoric acid were used. For light activation, the brackets were divided according to the light source to be used (n-15): LED UltraLume 5 (L); Apollo 95E plasma arc (AP) and Halogen light XL 2500 (H). After 24 h the samples were submitted to shear bond strength testing at crosshead speed of 0.5 mm/minute. RESULTS: The data were submitted to the analysis of variance (ANOVA) and the Tukey test (5%). Bond Strength: UltraLume 5 (11.4 ± 3.56 MPa) was superior to XL 2500 (9.12 ± 2.83 MPa) and Plasma Arc (5.11 ± 2.93 MPa) (p<0.05). No difference was found between ceramic with silane (8.31 ± 4.17 MPa) and without silane (8.68 ± 3.86 MPa). Etching time of 2 minutes (9.13 ± 3.98 MPa) was superior to time of 1 minute (7.86 ± 3.96 MPa). CONCLUSION: The results showed that LED was shown to be more efficient for polymerizing the material for Transbond XT bonding. The use of silane did not influence the bond strength values. The acid etching time of 2 minutes was more effective than that of 1 minute. |
id |
FSLM-1_feda88d593f10da6fb6fc164a253fe56 |
---|---|
oai_identifier_str |
oai:scielo:S1981-86372014000200117 |
network_acronym_str |
FSLM-1 |
network_name_str |
RGO - Revista Gaúcha de Odontologia (Online) |
repository_id_str |
|
spelling |
Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylindersOrthodontic bracketsOrthodonticsShear strength OBJECTIVE: To evaluate the shear bond strength of brackets bonded to ceramic with Transbond XT resin, etching time intervals (1 and 2 minutes) and three Light sources (Xenon Plasma Arc, LED and Halogen Light ), with and without silane. METHODS: In total, 12 feldspathic ceramic cylinders (15 mm x 20 mm), etched with 10% hydrofluoric acid were used. For light activation, the brackets were divided according to the light source to be used (n-15): LED UltraLume 5 (L); Apollo 95E plasma arc (AP) and Halogen light XL 2500 (H). After 24 h the samples were submitted to shear bond strength testing at crosshead speed of 0.5 mm/minute. RESULTS: The data were submitted to the analysis of variance (ANOVA) and the Tukey test (5%). Bond Strength: UltraLume 5 (11.4 ± 3.56 MPa) was superior to XL 2500 (9.12 ± 2.83 MPa) and Plasma Arc (5.11 ± 2.93 MPa) (p<0.05). No difference was found between ceramic with silane (8.31 ± 4.17 MPa) and without silane (8.68 ± 3.86 MPa). Etching time of 2 minutes (9.13 ± 3.98 MPa) was superior to time of 1 minute (7.86 ± 3.96 MPa). CONCLUSION: The results showed that LED was shown to be more efficient for polymerizing the material for Transbond XT bonding. The use of silane did not influence the bond strength values. The acid etching time of 2 minutes was more effective than that of 1 minute.Faculdade São Leopoldo Mandic2014-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372014000200117RGO - Revista Gaúcha de Odontologia v.62 n.2 2014reponame:RGO - Revista Gaúcha de Odontologia (Online)instname:Faculdade São Leopoldo Mandic (FSLM)instacron:FSLM10.1590/1981-863720140002000021536info:eu-repo/semantics/openAccessPIAIA,Magda ReginaCOSTA,Ana RosaCORRER,Américo BortolazzoCORRER-SOBRINHO,LourençoGARBUI,Ivana UglikNOUER,Paulo Roberto Aranhaeng2019-08-06T00:00:00Zoai:scielo:S1981-86372014000200117Revistahttp://revodonto.bvsalud.org/scielo.php?script=sci_serial&pid=1981-8637&lng=pt&nrm=isohttps://old.scielo.br/oai/scielo-oai.php||contato@revistargo.com.br1981-86370103-6971opendoar:2019-08-06T00:00RGO - Revista Gaúcha de Odontologia (Online) - Faculdade São Leopoldo Mandic (FSLM)false |
dc.title.none.fl_str_mv |
Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders |
title |
Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders |
spellingShingle |
Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders PIAIA,Magda Regina Orthodontic brackets Orthodontics Shear strength |
title_short |
Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders |
title_full |
Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders |
title_fullStr |
Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders |
title_full_unstemmed |
Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders |
title_sort |
Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders |
author |
PIAIA,Magda Regina |
author_facet |
PIAIA,Magda Regina COSTA,Ana Rosa CORRER,Américo Bortolazzo CORRER-SOBRINHO,Lourenço GARBUI,Ivana Uglik NOUER,Paulo Roberto Aranha |
author_role |
author |
author2 |
COSTA,Ana Rosa CORRER,Américo Bortolazzo CORRER-SOBRINHO,Lourenço GARBUI,Ivana Uglik NOUER,Paulo Roberto Aranha |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
PIAIA,Magda Regina COSTA,Ana Rosa CORRER,Américo Bortolazzo CORRER-SOBRINHO,Lourenço GARBUI,Ivana Uglik NOUER,Paulo Roberto Aranha |
dc.subject.por.fl_str_mv |
Orthodontic brackets Orthodontics Shear strength |
topic |
Orthodontic brackets Orthodontics Shear strength |
description |
OBJECTIVE: To evaluate the shear bond strength of brackets bonded to ceramic with Transbond XT resin, etching time intervals (1 and 2 minutes) and three Light sources (Xenon Plasma Arc, LED and Halogen Light ), with and without silane. METHODS: In total, 12 feldspathic ceramic cylinders (15 mm x 20 mm), etched with 10% hydrofluoric acid were used. For light activation, the brackets were divided according to the light source to be used (n-15): LED UltraLume 5 (L); Apollo 95E plasma arc (AP) and Halogen light XL 2500 (H). After 24 h the samples were submitted to shear bond strength testing at crosshead speed of 0.5 mm/minute. RESULTS: The data were submitted to the analysis of variance (ANOVA) and the Tukey test (5%). Bond Strength: UltraLume 5 (11.4 ± 3.56 MPa) was superior to XL 2500 (9.12 ± 2.83 MPa) and Plasma Arc (5.11 ± 2.93 MPa) (p<0.05). No difference was found between ceramic with silane (8.31 ± 4.17 MPa) and without silane (8.68 ± 3.86 MPa). Etching time of 2 minutes (9.13 ± 3.98 MPa) was superior to time of 1 minute (7.86 ± 3.96 MPa). CONCLUSION: The results showed that LED was shown to be more efficient for polymerizing the material for Transbond XT bonding. The use of silane did not influence the bond strength values. The acid etching time of 2 minutes was more effective than that of 1 minute. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372014000200117 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372014000200117 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1981-863720140002000021536 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Faculdade São Leopoldo Mandic |
publisher.none.fl_str_mv |
Faculdade São Leopoldo Mandic |
dc.source.none.fl_str_mv |
RGO - Revista Gaúcha de Odontologia v.62 n.2 2014 reponame:RGO - Revista Gaúcha de Odontologia (Online) instname:Faculdade São Leopoldo Mandic (FSLM) instacron:FSLM |
instname_str |
Faculdade São Leopoldo Mandic (FSLM) |
instacron_str |
FSLM |
institution |
FSLM |
reponame_str |
RGO - Revista Gaúcha de Odontologia (Online) |
collection |
RGO - Revista Gaúcha de Odontologia (Online) |
repository.name.fl_str_mv |
RGO - Revista Gaúcha de Odontologia (Online) - Faculdade São Leopoldo Mandic (FSLM) |
repository.mail.fl_str_mv |
||contato@revistargo.com.br |
_version_ |
1754204121110413312 |