Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders

Detalhes bibliográficos
Autor(a) principal: PIAIA,Magda Regina
Data de Publicação: 2014
Outros Autores: COSTA,Ana Rosa, CORRER,Américo Bortolazzo, CORRER-SOBRINHO,Lourenço, GARBUI,Ivana Uglik, NOUER,Paulo Roberto Aranha
Tipo de documento: Artigo
Idioma: eng
Título da fonte: RGO - Revista Gaúcha de Odontologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372014000200117
Resumo: OBJECTIVE: To evaluate the shear bond strength of brackets bonded to ceramic with Transbond XT resin, etching time intervals (1 and 2 minutes) and three Light sources (Xenon Plasma Arc, LED and Halogen Light ), with and without silane. METHODS: In total, 12 feldspathic ceramic cylinders (15 mm x 20 mm), etched with 10% hydrofluoric acid were used. For light activation, the brackets were divided according to the light source to be used (n-15): LED UltraLume 5 (L); Apollo 95E plasma arc (AP) and Halogen light XL 2500 (H). After 24 h the samples were submitted to shear bond strength testing at crosshead speed of 0.5 mm/minute. RESULTS: The data were submitted to the analysis of variance (ANOVA) and the Tukey test (5%). Bond Strength: UltraLume 5 (11.4 ± 3.56 MPa) was superior to XL 2500 (9.12 ± 2.83 MPa) and Plasma Arc (5.11 ± 2.93 MPa) (p<0.05). No difference was found between ceramic with silane (8.31 ± 4.17 MPa) and without silane (8.68 ± 3.86 MPa). Etching time of 2 minutes (9.13 ± 3.98 MPa) was superior to time of 1 minute (7.86 ± 3.96 MPa). CONCLUSION: The results showed that LED was shown to be more efficient for polymerizing the material for Transbond XT bonding. The use of silane did not influence the bond strength values. The acid etching time of 2 minutes was more effective than that of 1 minute.
id FSLM-1_feda88d593f10da6fb6fc164a253fe56
oai_identifier_str oai:scielo:S1981-86372014000200117
network_acronym_str FSLM-1
network_name_str RGO - Revista Gaúcha de Odontologia (Online)
repository_id_str
spelling Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylindersOrthodontic bracketsOrthodonticsShear strength OBJECTIVE: To evaluate the shear bond strength of brackets bonded to ceramic with Transbond XT resin, etching time intervals (1 and 2 minutes) and three Light sources (Xenon Plasma Arc, LED and Halogen Light ), with and without silane. METHODS: In total, 12 feldspathic ceramic cylinders (15 mm x 20 mm), etched with 10% hydrofluoric acid were used. For light activation, the brackets were divided according to the light source to be used (n-15): LED UltraLume 5 (L); Apollo 95E plasma arc (AP) and Halogen light XL 2500 (H). After 24 h the samples were submitted to shear bond strength testing at crosshead speed of 0.5 mm/minute. RESULTS: The data were submitted to the analysis of variance (ANOVA) and the Tukey test (5%). Bond Strength: UltraLume 5 (11.4 ± 3.56 MPa) was superior to XL 2500 (9.12 ± 2.83 MPa) and Plasma Arc (5.11 ± 2.93 MPa) (p<0.05). No difference was found between ceramic with silane (8.31 ± 4.17 MPa) and without silane (8.68 ± 3.86 MPa). Etching time of 2 minutes (9.13 ± 3.98 MPa) was superior to time of 1 minute (7.86 ± 3.96 MPa). CONCLUSION: The results showed that LED was shown to be more efficient for polymerizing the material for Transbond XT bonding. The use of silane did not influence the bond strength values. The acid etching time of 2 minutes was more effective than that of 1 minute.Faculdade São Leopoldo Mandic2014-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372014000200117RGO - Revista Gaúcha de Odontologia v.62 n.2 2014reponame:RGO - Revista Gaúcha de Odontologia (Online)instname:Faculdade São Leopoldo Mandic (FSLM)instacron:FSLM10.1590/1981-863720140002000021536info:eu-repo/semantics/openAccessPIAIA,Magda ReginaCOSTA,Ana RosaCORRER,Américo BortolazzoCORRER-SOBRINHO,LourençoGARBUI,Ivana UglikNOUER,Paulo Roberto Aranhaeng2019-08-06T00:00:00Zoai:scielo:S1981-86372014000200117Revistahttp://revodonto.bvsalud.org/scielo.php?script=sci_serial&pid=1981-8637&lng=pt&nrm=isohttps://old.scielo.br/oai/scielo-oai.php||contato@revistargo.com.br1981-86370103-6971opendoar:2019-08-06T00:00RGO - Revista Gaúcha de Odontologia (Online) - Faculdade São Leopoldo Mandic (FSLM)false
dc.title.none.fl_str_mv Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders
title Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders
spellingShingle Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders
PIAIA,Magda Regina
Orthodontic brackets
Orthodontics
Shear strength
title_short Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders
title_full Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders
title_fullStr Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders
title_full_unstemmed Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders
title_sort Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders
author PIAIA,Magda Regina
author_facet PIAIA,Magda Regina
COSTA,Ana Rosa
CORRER,Américo Bortolazzo
CORRER-SOBRINHO,Lourenço
GARBUI,Ivana Uglik
NOUER,Paulo Roberto Aranha
author_role author
author2 COSTA,Ana Rosa
CORRER,Américo Bortolazzo
CORRER-SOBRINHO,Lourenço
GARBUI,Ivana Uglik
NOUER,Paulo Roberto Aranha
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv PIAIA,Magda Regina
COSTA,Ana Rosa
CORRER,Américo Bortolazzo
CORRER-SOBRINHO,Lourenço
GARBUI,Ivana Uglik
NOUER,Paulo Roberto Aranha
dc.subject.por.fl_str_mv Orthodontic brackets
Orthodontics
Shear strength
topic Orthodontic brackets
Orthodontics
Shear strength
description OBJECTIVE: To evaluate the shear bond strength of brackets bonded to ceramic with Transbond XT resin, etching time intervals (1 and 2 minutes) and three Light sources (Xenon Plasma Arc, LED and Halogen Light ), with and without silane. METHODS: In total, 12 feldspathic ceramic cylinders (15 mm x 20 mm), etched with 10% hydrofluoric acid were used. For light activation, the brackets were divided according to the light source to be used (n-15): LED UltraLume 5 (L); Apollo 95E plasma arc (AP) and Halogen light XL 2500 (H). After 24 h the samples were submitted to shear bond strength testing at crosshead speed of 0.5 mm/minute. RESULTS: The data were submitted to the analysis of variance (ANOVA) and the Tukey test (5%). Bond Strength: UltraLume 5 (11.4 ± 3.56 MPa) was superior to XL 2500 (9.12 ± 2.83 MPa) and Plasma Arc (5.11 ± 2.93 MPa) (p<0.05). No difference was found between ceramic with silane (8.31 ± 4.17 MPa) and without silane (8.68 ± 3.86 MPa). Etching time of 2 minutes (9.13 ± 3.98 MPa) was superior to time of 1 minute (7.86 ± 3.96 MPa). CONCLUSION: The results showed that LED was shown to be more efficient for polymerizing the material for Transbond XT bonding. The use of silane did not influence the bond strength values. The acid etching time of 2 minutes was more effective than that of 1 minute.
publishDate 2014
dc.date.none.fl_str_mv 2014-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372014000200117
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372014000200117
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1981-863720140002000021536
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Faculdade São Leopoldo Mandic
publisher.none.fl_str_mv Faculdade São Leopoldo Mandic
dc.source.none.fl_str_mv RGO - Revista Gaúcha de Odontologia v.62 n.2 2014
reponame:RGO - Revista Gaúcha de Odontologia (Online)
instname:Faculdade São Leopoldo Mandic (FSLM)
instacron:FSLM
instname_str Faculdade São Leopoldo Mandic (FSLM)
instacron_str FSLM
institution FSLM
reponame_str RGO - Revista Gaúcha de Odontologia (Online)
collection RGO - Revista Gaúcha de Odontologia (Online)
repository.name.fl_str_mv RGO - Revista Gaúcha de Odontologia (Online) - Faculdade São Leopoldo Mandic (FSLM)
repository.mail.fl_str_mv ||contato@revistargo.com.br
_version_ 1754204121110413312