Comparative study of ceramic-to-metal bonding

Detalhes bibliográficos
Autor(a) principal: Scolaro,Juliano Milczewsky
Data de Publicação: 2007
Outros Autores: Pereira,Jefferson Ricardo, Valle,Accácio Lins do, Bonfante,Gerson, Pegoraro,Luiz Fernando
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402007000300012
Resumo: Dentists and technicians have used dental ceramics associated with different types of alloys without taking into account the characteristics of compatibility of these materials. Knowing the properties of the alloy and ceramic used in metal/ceramic restorations is a key factor for treatment success. The purpose of this study was to evaluate the bond strength of a palladium-silver alloy (Pors-on 4) to 3 ceramics (Ceramco, Noritake and Vita VMK-68) using shear forces at the metal-ceramic interface. A stainless steel cylindrical matrix was used for preparation of the metal dies, application of ceramic and shear strength testing. Thirty palladium-silver alloy cylinders received two layers of opaque and two layers of body porcelain, and shear tests were performed in a universal testing machine at a cross-head speed of 0.5 mm/min. Shear bond strength means (in MPa) were: 28.21(Ceramco), 28.96 (Noritake) and 24.11 (Vita VMK-68). One-way ANOVA did not show statistically significant differences (p>0.05) among the materials. The results of this study indicate that the three evaluated ceramic systems are suitable to be used in combination with the tested palladium-silver alloy.
id FUNORP-1_2792539559c443b725160b875654f421
oai_identifier_str oai:scielo:S0103-64402007000300012
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Comparative study of ceramic-to-metal bondingMetaloceramic restorationsalloysceramicscompressive strengthDentists and technicians have used dental ceramics associated with different types of alloys without taking into account the characteristics of compatibility of these materials. Knowing the properties of the alloy and ceramic used in metal/ceramic restorations is a key factor for treatment success. The purpose of this study was to evaluate the bond strength of a palladium-silver alloy (Pors-on 4) to 3 ceramics (Ceramco, Noritake and Vita VMK-68) using shear forces at the metal-ceramic interface. A stainless steel cylindrical matrix was used for preparation of the metal dies, application of ceramic and shear strength testing. Thirty palladium-silver alloy cylinders received two layers of opaque and two layers of body porcelain, and shear tests were performed in a universal testing machine at a cross-head speed of 0.5 mm/min. Shear bond strength means (in MPa) were: 28.21(Ceramco), 28.96 (Noritake) and 24.11 (Vita VMK-68). One-way ANOVA did not show statistically significant differences (p>0.05) among the materials. The results of this study indicate that the three evaluated ceramic systems are suitable to be used in combination with the tested palladium-silver alloy.Fundação Odontológica de Ribeirão Preto2007-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402007000300012Brazilian Dental Journal v.18 n.3 2007reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402007000300012info:eu-repo/semantics/openAccessScolaro,Juliano MilczewskyPereira,Jefferson RicardoValle,Accácio Lins doBonfante,GersonPegoraro,Luiz Fernandoeng2008-01-02T00:00:00Zoai:scielo:S0103-64402007000300012Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2008-01-02T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Comparative study of ceramic-to-metal bonding
title Comparative study of ceramic-to-metal bonding
spellingShingle Comparative study of ceramic-to-metal bonding
Scolaro,Juliano Milczewsky
Metaloceramic restorations
alloys
ceramics
compressive strength
title_short Comparative study of ceramic-to-metal bonding
title_full Comparative study of ceramic-to-metal bonding
title_fullStr Comparative study of ceramic-to-metal bonding
title_full_unstemmed Comparative study of ceramic-to-metal bonding
title_sort Comparative study of ceramic-to-metal bonding
author Scolaro,Juliano Milczewsky
author_facet Scolaro,Juliano Milczewsky
Pereira,Jefferson Ricardo
Valle,Accácio Lins do
Bonfante,Gerson
Pegoraro,Luiz Fernando
author_role author
author2 Pereira,Jefferson Ricardo
Valle,Accácio Lins do
Bonfante,Gerson
Pegoraro,Luiz Fernando
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Scolaro,Juliano Milczewsky
Pereira,Jefferson Ricardo
Valle,Accácio Lins do
Bonfante,Gerson
Pegoraro,Luiz Fernando
dc.subject.por.fl_str_mv Metaloceramic restorations
alloys
ceramics
compressive strength
topic Metaloceramic restorations
alloys
ceramics
compressive strength
description Dentists and technicians have used dental ceramics associated with different types of alloys without taking into account the characteristics of compatibility of these materials. Knowing the properties of the alloy and ceramic used in metal/ceramic restorations is a key factor for treatment success. The purpose of this study was to evaluate the bond strength of a palladium-silver alloy (Pors-on 4) to 3 ceramics (Ceramco, Noritake and Vita VMK-68) using shear forces at the metal-ceramic interface. A stainless steel cylindrical matrix was used for preparation of the metal dies, application of ceramic and shear strength testing. Thirty palladium-silver alloy cylinders received two layers of opaque and two layers of body porcelain, and shear tests were performed in a universal testing machine at a cross-head speed of 0.5 mm/min. Shear bond strength means (in MPa) were: 28.21(Ceramco), 28.96 (Noritake) and 24.11 (Vita VMK-68). One-way ANOVA did not show statistically significant differences (p>0.05) among the materials. The results of this study indicate that the three evaluated ceramic systems are suitable to be used in combination with the tested palladium-silver alloy.
publishDate 2007
dc.date.none.fl_str_mv 2007-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402007000300012
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402007000300012
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402007000300012
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.18 n.3 2007
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204090538131456