Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402003000300013
Resumo: The reliability of the linear tomography and panoramic radiography made with X-ray equipment was evaluated (Vera View Scope X-600; Morita). The sample was composed of 20 dry human hemimandibles, in which the area selected for analysis was 1.5 cm distal from the limit set before the mental foramen. Four measurements were made. The images obtained were drawn on acetate paper and the hemimandibles cut at the demarcated area. The measurements were made using a digital electronic pachymeter. The values found for the radiographic images were compared to those obtained in the mandibular specimens and submitted to statistical evaluation by the Wilcoxon test. It was concluded that both techniques were reliable for the accomplishment of vertical linear measurements in the selected area. However, a 2.0 mm safety margin is recommended.
id FUNORP-1_28723cc0a1048a63a838df71e093eb62
oai_identifier_str oai:scielo:S0103-64402003000300013
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Evaluation of mandibular implant sites: correlation between panoramic and linear tomographymandiblelinear tomographypanoramic radiographyimplantsThe reliability of the linear tomography and panoramic radiography made with X-ray equipment was evaluated (Vera View Scope X-600; Morita). The sample was composed of 20 dry human hemimandibles, in which the area selected for analysis was 1.5 cm distal from the limit set before the mental foramen. Four measurements were made. The images obtained were drawn on acetate paper and the hemimandibles cut at the demarcated area. The measurements were made using a digital electronic pachymeter. The values found for the radiographic images were compared to those obtained in the mandibular specimens and submitted to statistical evaluation by the Wilcoxon test. It was concluded that both techniques were reliable for the accomplishment of vertical linear measurements in the selected area. However, a 2.0 mm safety margin is recommended.Fundação Odontológica de Ribeirão Preto2003-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402003000300013Brazilian Dental Journal v.14 n.3 2003reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402003000300013info:eu-repo/semantics/openAccessRockenbach,Maria Ivete BolzanSampaio,Maria Carméli CorreiaCosta,Lino João daCosta,Nilza Pereira daeng2004-03-29T00:00:00Zoai:scielo:S0103-64402003000300013Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2004-03-29T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Evaluation of mandibular implant sites: correlation between panoramic and linear tomography
title Evaluation of mandibular implant sites: correlation between panoramic and linear tomography
spellingShingle Evaluation of mandibular implant sites: correlation between panoramic and linear tomography
Rockenbach,Maria Ivete Bolzan
mandible
linear tomography
panoramic radiography
implants
title_short Evaluation of mandibular implant sites: correlation between panoramic and linear tomography
title_full Evaluation of mandibular implant sites: correlation between panoramic and linear tomography
title_fullStr Evaluation of mandibular implant sites: correlation between panoramic and linear tomography
title_full_unstemmed Evaluation of mandibular implant sites: correlation between panoramic and linear tomography
title_sort Evaluation of mandibular implant sites: correlation between panoramic and linear tomography
author Rockenbach,Maria Ivete Bolzan
author_facet Rockenbach,Maria Ivete Bolzan
Sampaio,Maria Carméli Correia
Costa,Lino João da
Costa,Nilza Pereira da
author_role author
author2 Sampaio,Maria Carméli Correia
Costa,Lino João da
Costa,Nilza Pereira da
author2_role author
author
author
dc.contributor.author.fl_str_mv Rockenbach,Maria Ivete Bolzan
Sampaio,Maria Carméli Correia
Costa,Lino João da
Costa,Nilza Pereira da
dc.subject.por.fl_str_mv mandible
linear tomography
panoramic radiography
implants
topic mandible
linear tomography
panoramic radiography
implants
description The reliability of the linear tomography and panoramic radiography made with X-ray equipment was evaluated (Vera View Scope X-600; Morita). The sample was composed of 20 dry human hemimandibles, in which the area selected for analysis was 1.5 cm distal from the limit set before the mental foramen. Four measurements were made. The images obtained were drawn on acetate paper and the hemimandibles cut at the demarcated area. The measurements were made using a digital electronic pachymeter. The values found for the radiographic images were compared to those obtained in the mandibular specimens and submitted to statistical evaluation by the Wilcoxon test. It was concluded that both techniques were reliable for the accomplishment of vertical linear measurements in the selected area. However, a 2.0 mm safety margin is recommended.
publishDate 2003
dc.date.none.fl_str_mv 2003-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402003000300013
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402003000300013
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402003000300013
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.14 n.3 2003
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204089713950720