Evaluation of mandibular implant sites: correlation between panoramic and linear tomography
Autor(a) principal: | |
---|---|
Data de Publicação: | 2003 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Dental Journal |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402003000300013 |
Resumo: | The reliability of the linear tomography and panoramic radiography made with X-ray equipment was evaluated (Vera View Scope X-600; Morita). The sample was composed of 20 dry human hemimandibles, in which the area selected for analysis was 1.5 cm distal from the limit set before the mental foramen. Four measurements were made. The images obtained were drawn on acetate paper and the hemimandibles cut at the demarcated area. The measurements were made using a digital electronic pachymeter. The values found for the radiographic images were compared to those obtained in the mandibular specimens and submitted to statistical evaluation by the Wilcoxon test. It was concluded that both techniques were reliable for the accomplishment of vertical linear measurements in the selected area. However, a 2.0 mm safety margin is recommended. |
id |
FUNORP-1_28723cc0a1048a63a838df71e093eb62 |
---|---|
oai_identifier_str |
oai:scielo:S0103-64402003000300013 |
network_acronym_str |
FUNORP-1 |
network_name_str |
Brazilian Dental Journal |
repository_id_str |
|
spelling |
Evaluation of mandibular implant sites: correlation between panoramic and linear tomographymandiblelinear tomographypanoramic radiographyimplantsThe reliability of the linear tomography and panoramic radiography made with X-ray equipment was evaluated (Vera View Scope X-600; Morita). The sample was composed of 20 dry human hemimandibles, in which the area selected for analysis was 1.5 cm distal from the limit set before the mental foramen. Four measurements were made. The images obtained were drawn on acetate paper and the hemimandibles cut at the demarcated area. The measurements were made using a digital electronic pachymeter. The values found for the radiographic images were compared to those obtained in the mandibular specimens and submitted to statistical evaluation by the Wilcoxon test. It was concluded that both techniques were reliable for the accomplishment of vertical linear measurements in the selected area. However, a 2.0 mm safety margin is recommended.Fundação Odontológica de Ribeirão Preto2003-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402003000300013Brazilian Dental Journal v.14 n.3 2003reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402003000300013info:eu-repo/semantics/openAccessRockenbach,Maria Ivete BolzanSampaio,Maria Carméli CorreiaCosta,Lino João daCosta,Nilza Pereira daeng2004-03-29T00:00:00Zoai:scielo:S0103-64402003000300013Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2004-03-29T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false |
dc.title.none.fl_str_mv |
Evaluation of mandibular implant sites: correlation between panoramic and linear tomography |
title |
Evaluation of mandibular implant sites: correlation between panoramic and linear tomography |
spellingShingle |
Evaluation of mandibular implant sites: correlation between panoramic and linear tomography Rockenbach,Maria Ivete Bolzan mandible linear tomography panoramic radiography implants |
title_short |
Evaluation of mandibular implant sites: correlation between panoramic and linear tomography |
title_full |
Evaluation of mandibular implant sites: correlation between panoramic and linear tomography |
title_fullStr |
Evaluation of mandibular implant sites: correlation between panoramic and linear tomography |
title_full_unstemmed |
Evaluation of mandibular implant sites: correlation between panoramic and linear tomography |
title_sort |
Evaluation of mandibular implant sites: correlation between panoramic and linear tomography |
author |
Rockenbach,Maria Ivete Bolzan |
author_facet |
Rockenbach,Maria Ivete Bolzan Sampaio,Maria Carméli Correia Costa,Lino João da Costa,Nilza Pereira da |
author_role |
author |
author2 |
Sampaio,Maria Carméli Correia Costa,Lino João da Costa,Nilza Pereira da |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Rockenbach,Maria Ivete Bolzan Sampaio,Maria Carméli Correia Costa,Lino João da Costa,Nilza Pereira da |
dc.subject.por.fl_str_mv |
mandible linear tomography panoramic radiography implants |
topic |
mandible linear tomography panoramic radiography implants |
description |
The reliability of the linear tomography and panoramic radiography made with X-ray equipment was evaluated (Vera View Scope X-600; Morita). The sample was composed of 20 dry human hemimandibles, in which the area selected for analysis was 1.5 cm distal from the limit set before the mental foramen. Four measurements were made. The images obtained were drawn on acetate paper and the hemimandibles cut at the demarcated area. The measurements were made using a digital electronic pachymeter. The values found for the radiographic images were compared to those obtained in the mandibular specimens and submitted to statistical evaluation by the Wilcoxon test. It was concluded that both techniques were reliable for the accomplishment of vertical linear measurements in the selected area. However, a 2.0 mm safety margin is recommended. |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402003000300013 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402003000300013 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-64402003000300013 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
dc.source.none.fl_str_mv |
Brazilian Dental Journal v.14 n.3 2003 reponame:Brazilian Dental Journal instname:Fundação Odontológica de Ribeirão Preto (FUNORP) instacron:FUNORP |
instname_str |
Fundação Odontológica de Ribeirão Preto (FUNORP) |
instacron_str |
FUNORP |
institution |
FUNORP |
reponame_str |
Brazilian Dental Journal |
collection |
Brazilian Dental Journal |
repository.name.fl_str_mv |
Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP) |
repository.mail.fl_str_mv |
bdj@forp.usp.br||sergio@fosjc.unesp.br |
_version_ |
1754204089713950720 |