Effect of Time Lapse on the Diagnostic Accuracy of Cone Beam Computed Tomography for Detection of Vertical Root Fractures

Detalhes bibliográficos
Autor(a) principal: Eskandarloo,Amir
Data de Publicação: 2016
Outros Autores: Asl,Amin Mahdavi, Jalalzadeh,Mohsen, Tayari,Maryam, Hosseinipanah,Mohammad, Fardmal,Javad, Shokri,Abbas
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402016000100016
Resumo: Abstract Accurate and early diagnosis of vertical root fractures (VRFs) is imperative to prevent extensive bone loss and unnecessary endodontic and prosthodontic treatments. The aim of this study was to assess the effect of time lapse on the diagnostic accuracy of cone beam computed tomography (CBCT) for VRFs in endodontically treated dog's teeth. Forty-eight incisors and premolars of three adult male dogs underwent root canal therapy. The teeth were assigned to two groups: VRFs were artificially induced in the first group (n=24) while the teeth in the second group remained intact (n=24). The CBCT scans were obtained by NewTom 3G unit immediately after inducing VRFs and after one, two, three, four, eight, 12 and 16 weeks. Three oral and maxillofacial radiologists blinded to the date of radiographs assessed the presence/absence of VRFs on CBCT scans. The sensitivity, specificity and accuracy values were calculated and data were analyzed using SPSS v.16 software and ANOVA. The total accuracy of detection of VRFs immediately after surgery, one, two, three, four, eight, 12 and 16 weeks was 67.3%, 68.7%, 66.6%, 64.6%, 64.5%, 69.4%, 68.7%, 68% respectively. The effect of time lapse on detection of VRFs was not significant (p>0.05). Overall sensitivity, specificity and accuracy of CBCT for detection of VRFs were 74.3%, 62.2%, 67.2% respectively. Cone beam computed tomography is a valuable tool for detection of VRFs. Time lapse (four months) had no effect on detection of VRFs on CBCT scans.
id FUNORP-1_2a43c5dcc05e92ea29ab5c175e18b56a
oai_identifier_str oai:scielo:S0103-64402016000100016
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Effect of Time Lapse on the Diagnostic Accuracy of Cone Beam Computed Tomography for Detection of Vertical Root Fracturescone-beam computed tomographytooth rootfracturedogs.Abstract Accurate and early diagnosis of vertical root fractures (VRFs) is imperative to prevent extensive bone loss and unnecessary endodontic and prosthodontic treatments. The aim of this study was to assess the effect of time lapse on the diagnostic accuracy of cone beam computed tomography (CBCT) for VRFs in endodontically treated dog's teeth. Forty-eight incisors and premolars of three adult male dogs underwent root canal therapy. The teeth were assigned to two groups: VRFs were artificially induced in the first group (n=24) while the teeth in the second group remained intact (n=24). The CBCT scans were obtained by NewTom 3G unit immediately after inducing VRFs and after one, two, three, four, eight, 12 and 16 weeks. Three oral and maxillofacial radiologists blinded to the date of radiographs assessed the presence/absence of VRFs on CBCT scans. The sensitivity, specificity and accuracy values were calculated and data were analyzed using SPSS v.16 software and ANOVA. The total accuracy of detection of VRFs immediately after surgery, one, two, three, four, eight, 12 and 16 weeks was 67.3%, 68.7%, 66.6%, 64.6%, 64.5%, 69.4%, 68.7%, 68% respectively. The effect of time lapse on detection of VRFs was not significant (p>0.05). Overall sensitivity, specificity and accuracy of CBCT for detection of VRFs were 74.3%, 62.2%, 67.2% respectively. Cone beam computed tomography is a valuable tool for detection of VRFs. Time lapse (four months) had no effect on detection of VRFs on CBCT scans.Fundação Odontológica de Ribeirão Preto2016-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402016000100016Brazilian Dental Journal v.27 n.1 2016reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440201600455info:eu-repo/semantics/openAccessEskandarloo,AmirAsl,Amin MahdaviJalalzadeh,MohsenTayari,MaryamHosseinipanah,MohammadFardmal,JavadShokri,Abbaseng2016-03-18T00:00:00Zoai:scielo:S0103-64402016000100016Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2016-03-18T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Effect of Time Lapse on the Diagnostic Accuracy of Cone Beam Computed Tomography for Detection of Vertical Root Fractures
title Effect of Time Lapse on the Diagnostic Accuracy of Cone Beam Computed Tomography for Detection of Vertical Root Fractures
spellingShingle Effect of Time Lapse on the Diagnostic Accuracy of Cone Beam Computed Tomography for Detection of Vertical Root Fractures
Eskandarloo,Amir
cone-beam computed tomography
tooth root
fracture
dogs.
title_short Effect of Time Lapse on the Diagnostic Accuracy of Cone Beam Computed Tomography for Detection of Vertical Root Fractures
title_full Effect of Time Lapse on the Diagnostic Accuracy of Cone Beam Computed Tomography for Detection of Vertical Root Fractures
title_fullStr Effect of Time Lapse on the Diagnostic Accuracy of Cone Beam Computed Tomography for Detection of Vertical Root Fractures
title_full_unstemmed Effect of Time Lapse on the Diagnostic Accuracy of Cone Beam Computed Tomography for Detection of Vertical Root Fractures
title_sort Effect of Time Lapse on the Diagnostic Accuracy of Cone Beam Computed Tomography for Detection of Vertical Root Fractures
author Eskandarloo,Amir
author_facet Eskandarloo,Amir
Asl,Amin Mahdavi
Jalalzadeh,Mohsen
Tayari,Maryam
Hosseinipanah,Mohammad
Fardmal,Javad
Shokri,Abbas
author_role author
author2 Asl,Amin Mahdavi
Jalalzadeh,Mohsen
Tayari,Maryam
Hosseinipanah,Mohammad
Fardmal,Javad
Shokri,Abbas
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Eskandarloo,Amir
Asl,Amin Mahdavi
Jalalzadeh,Mohsen
Tayari,Maryam
Hosseinipanah,Mohammad
Fardmal,Javad
Shokri,Abbas
dc.subject.por.fl_str_mv cone-beam computed tomography
tooth root
fracture
dogs.
topic cone-beam computed tomography
tooth root
fracture
dogs.
description Abstract Accurate and early diagnosis of vertical root fractures (VRFs) is imperative to prevent extensive bone loss and unnecessary endodontic and prosthodontic treatments. The aim of this study was to assess the effect of time lapse on the diagnostic accuracy of cone beam computed tomography (CBCT) for VRFs in endodontically treated dog's teeth. Forty-eight incisors and premolars of three adult male dogs underwent root canal therapy. The teeth were assigned to two groups: VRFs were artificially induced in the first group (n=24) while the teeth in the second group remained intact (n=24). The CBCT scans were obtained by NewTom 3G unit immediately after inducing VRFs and after one, two, three, four, eight, 12 and 16 weeks. Three oral and maxillofacial radiologists blinded to the date of radiographs assessed the presence/absence of VRFs on CBCT scans. The sensitivity, specificity and accuracy values were calculated and data were analyzed using SPSS v.16 software and ANOVA. The total accuracy of detection of VRFs immediately after surgery, one, two, three, four, eight, 12 and 16 weeks was 67.3%, 68.7%, 66.6%, 64.6%, 64.5%, 69.4%, 68.7%, 68% respectively. The effect of time lapse on detection of VRFs was not significant (p>0.05). Overall sensitivity, specificity and accuracy of CBCT for detection of VRFs were 74.3%, 62.2%, 67.2% respectively. Cone beam computed tomography is a valuable tool for detection of VRFs. Time lapse (four months) had no effect on detection of VRFs on CBCT scans.
publishDate 2016
dc.date.none.fl_str_mv 2016-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402016000100016
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402016000100016
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0103-6440201600455
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.27 n.1 2016
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204093961732096