Load-Application Devices: A Comparative Strain Gauge Analysis

Detalhes bibliográficos
Autor(a) principal: Nishioka,Renato Sussumu
Data de Publicação: 2015
Outros Autores: Vasconcellos,Luis Gustavo Oliveira de, Jóias,Renata Pilli, Rode,Sigmar de Mello
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000300258
Resumo: In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.
id FUNORP-1_2bf2ed429a5fffdbe364acb5460b9e45
oai_identifier_str oai:scielo:S0103-64402015000300258
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Load-Application Devices: A Comparative Strain Gauge Analysisdental implantsdental prosthesisimplant-supported dental prosthesisIn view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.Fundação Odontológica de Ribeirão Preto2015-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000300258Brazilian Dental Journal v.26 n.3 2015reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440201300321info:eu-repo/semantics/openAccessNishioka,Renato SussumuVasconcellos,Luis Gustavo Oliveira deJóias,Renata PilliRode,Sigmar de Melloeng2015-07-14T00:00:00Zoai:scielo:S0103-64402015000300258Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2015-07-14T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Load-Application Devices: A Comparative Strain Gauge Analysis
title Load-Application Devices: A Comparative Strain Gauge Analysis
spellingShingle Load-Application Devices: A Comparative Strain Gauge Analysis
Nishioka,Renato Sussumu
dental implants
dental prosthesis
implant-supported dental prosthesis
title_short Load-Application Devices: A Comparative Strain Gauge Analysis
title_full Load-Application Devices: A Comparative Strain Gauge Analysis
title_fullStr Load-Application Devices: A Comparative Strain Gauge Analysis
title_full_unstemmed Load-Application Devices: A Comparative Strain Gauge Analysis
title_sort Load-Application Devices: A Comparative Strain Gauge Analysis
author Nishioka,Renato Sussumu
author_facet Nishioka,Renato Sussumu
Vasconcellos,Luis Gustavo Oliveira de
Jóias,Renata Pilli
Rode,Sigmar de Mello
author_role author
author2 Vasconcellos,Luis Gustavo Oliveira de
Jóias,Renata Pilli
Rode,Sigmar de Mello
author2_role author
author
author
dc.contributor.author.fl_str_mv Nishioka,Renato Sussumu
Vasconcellos,Luis Gustavo Oliveira de
Jóias,Renata Pilli
Rode,Sigmar de Mello
dc.subject.por.fl_str_mv dental implants
dental prosthesis
implant-supported dental prosthesis
topic dental implants
dental prosthesis
implant-supported dental prosthesis
description In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.
publishDate 2015
dc.date.none.fl_str_mv 2015-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000300258
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000300258
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0103-6440201300321
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.26 n.3 2015
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204093540204544