Post-cure heat treatments influence on mechanical and optical properties of resin composites

Detalhes bibliográficos
Autor(a) principal: Baldo,Vitor de Oliveira
Data de Publicação: 2021
Outros Autores: Pedrosa,Marlus da Silva, Medeiros,Igor Studart
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402021000400096
Resumo: Abstract This study evaluated the effect of post-cure heat treatment (PCHT) on the Knoop microhardness (KHN), degree of conversion (DC), color changes, and contrast ratio (CR) of four resin composites (RCs): Z100 (3M ESPE), Z350 XT (3M ESPE), Estelite Omega (Tokuyama) and Empress Direct (Ivoclar Vivadent). Specimens (12 × 1 mm) were prepared for each material (n = 10 / group). After curing, samples were subjected to PCHT for 10 min at 100°C or 170°C. Control group was maintained at room temperature (24°C) for the same time. The DC was analyzed by FT-NIR immediately and 24 h after the PCHT (n = 3 / group). KHN was analyzed 24 h after PCHT (n = 10 / group). According to CIEDE2000 (∆E00), color measurements were obtained immediately after curing, five minutes after PCHT, and after seven days of storage in water, coffee, and red wine. Data were analyzed by One and Two-Way ANOVA (p < 0.05). Z100, Z350, and Estelite Omega showed increases in KHN with increased temperature (p < 0.05). PCHT at 100°C and 170°C led to a higher DC of all RCs (p < 0.05). Initially, the PCHT lead to increased ∆E00 values (p < 0.05), which was decreased after immersion in coffee and wine (p < 0.05). Considering the effect of PCHT and staining solutions, lower color changes were observed in the thermally treated specimens (p < 0.05). Taken collectively, the results suggest the PCHT as an economical and practical alternative to enhance direct RC's properties in direct-indirect and indirect restorations.
id FUNORP-1_3aa8ee35bff8922b87b3e880ab0d2b8b
oai_identifier_str oai:scielo:S0103-64402021000400096
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Post-cure heat treatments influence on mechanical and optical properties of resin compositesheatmechanical propertiesdental materialsresin compositesAbstract This study evaluated the effect of post-cure heat treatment (PCHT) on the Knoop microhardness (KHN), degree of conversion (DC), color changes, and contrast ratio (CR) of four resin composites (RCs): Z100 (3M ESPE), Z350 XT (3M ESPE), Estelite Omega (Tokuyama) and Empress Direct (Ivoclar Vivadent). Specimens (12 × 1 mm) were prepared for each material (n = 10 / group). After curing, samples were subjected to PCHT for 10 min at 100°C or 170°C. Control group was maintained at room temperature (24°C) for the same time. The DC was analyzed by FT-NIR immediately and 24 h after the PCHT (n = 3 / group). KHN was analyzed 24 h after PCHT (n = 10 / group). According to CIEDE2000 (∆E00), color measurements were obtained immediately after curing, five minutes after PCHT, and after seven days of storage in water, coffee, and red wine. Data were analyzed by One and Two-Way ANOVA (p < 0.05). Z100, Z350, and Estelite Omega showed increases in KHN with increased temperature (p < 0.05). PCHT at 100°C and 170°C led to a higher DC of all RCs (p < 0.05). Initially, the PCHT lead to increased ∆E00 values (p < 0.05), which was decreased after immersion in coffee and wine (p < 0.05). Considering the effect of PCHT and staining solutions, lower color changes were observed in the thermally treated specimens (p < 0.05). Taken collectively, the results suggest the PCHT as an economical and practical alternative to enhance direct RC's properties in direct-indirect and indirect restorations.Fundação Odontológica de Ribeirão Preto2021-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402021000400096Brazilian Dental Journal v.32 n.4 2021reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440202104333info:eu-repo/semantics/openAccessBaldo,Vitor de OliveiraPedrosa,Marlus da SilvaMedeiros,Igor Studarteng2021-11-09T00:00:00Zoai:scielo:S0103-64402021000400096Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2021-11-09T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Post-cure heat treatments influence on mechanical and optical properties of resin composites
title Post-cure heat treatments influence on mechanical and optical properties of resin composites
spellingShingle Post-cure heat treatments influence on mechanical and optical properties of resin composites
Baldo,Vitor de Oliveira
heat
mechanical properties
dental materials
resin composites
title_short Post-cure heat treatments influence on mechanical and optical properties of resin composites
title_full Post-cure heat treatments influence on mechanical and optical properties of resin composites
title_fullStr Post-cure heat treatments influence on mechanical and optical properties of resin composites
title_full_unstemmed Post-cure heat treatments influence on mechanical and optical properties of resin composites
title_sort Post-cure heat treatments influence on mechanical and optical properties of resin composites
author Baldo,Vitor de Oliveira
author_facet Baldo,Vitor de Oliveira
Pedrosa,Marlus da Silva
Medeiros,Igor Studart
author_role author
author2 Pedrosa,Marlus da Silva
Medeiros,Igor Studart
author2_role author
author
dc.contributor.author.fl_str_mv Baldo,Vitor de Oliveira
Pedrosa,Marlus da Silva
Medeiros,Igor Studart
dc.subject.por.fl_str_mv heat
mechanical properties
dental materials
resin composites
topic heat
mechanical properties
dental materials
resin composites
description Abstract This study evaluated the effect of post-cure heat treatment (PCHT) on the Knoop microhardness (KHN), degree of conversion (DC), color changes, and contrast ratio (CR) of four resin composites (RCs): Z100 (3M ESPE), Z350 XT (3M ESPE), Estelite Omega (Tokuyama) and Empress Direct (Ivoclar Vivadent). Specimens (12 × 1 mm) were prepared for each material (n = 10 / group). After curing, samples were subjected to PCHT for 10 min at 100°C or 170°C. Control group was maintained at room temperature (24°C) for the same time. The DC was analyzed by FT-NIR immediately and 24 h after the PCHT (n = 3 / group). KHN was analyzed 24 h after PCHT (n = 10 / group). According to CIEDE2000 (∆E00), color measurements were obtained immediately after curing, five minutes after PCHT, and after seven days of storage in water, coffee, and red wine. Data were analyzed by One and Two-Way ANOVA (p < 0.05). Z100, Z350, and Estelite Omega showed increases in KHN with increased temperature (p < 0.05). PCHT at 100°C and 170°C led to a higher DC of all RCs (p < 0.05). Initially, the PCHT lead to increased ∆E00 values (p < 0.05), which was decreased after immersion in coffee and wine (p < 0.05). Considering the effect of PCHT and staining solutions, lower color changes were observed in the thermally treated specimens (p < 0.05). Taken collectively, the results suggest the PCHT as an economical and practical alternative to enhance direct RC's properties in direct-indirect and indirect restorations.
publishDate 2021
dc.date.none.fl_str_mv 2021-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402021000400096
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402021000400096
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0103-6440202104333
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.32 n.4 2021
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204096279085056