Influence of photopolymerization light source on enamel shear bond strength after bleaching

Detalhes bibliográficos
Autor(a) principal: Loretto,Sandro Cordeiro
Data de Publicação: 2004
Outros Autores: Braz,Rodivan, Lyra,Arine Maria Víveros de Castro, Lopes,Luís Mário
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402004000200009
Resumo: This study evaluated the influence of 3 different photopolymerization sources on enamel shear bond strength after bleaching with 10% carbamide peroxide. Seventy-two incisive bovine teeth were randomly divided into 6 groups (n=12) according to bleaching treatment and photopolymerization source used: G1 - Bleached / Halogen lamp; G2 - Not bleached / Halogen lamp (control); G3 - Bleached / Light-emitting diodes (LED); G4 - Not bleached / Light-emitting diodes (LED) (control); G5 - Bleached / Xenon plasma arc; G6 - Not bleached / Xenon plasma arc (control). Experimental groups were exposed to bleaching agent for a period of 14 days, with a daily contact of 4 h and then stored in artificial saliva at 37ºC. Control groups were stored in artificial saliva at 37ºC for same period of bleaching treatment. Procedures for bonding composite resin to enamel were carried out according to manufacturer instructions. After storage in distilled water at 37ºC for 24 hours, all samples were submitted to shear bond strength test. G2 had the highest mean value (14.86 MPa) while G5 had the lowest (12.32 MPa). The comparison of groups by 2-way ANOVA showed that there were no significant differences for either of the factors considered in this study (bleaching and photopolymerization source), hence the interaction between these factors. It was therefore possible to conclude that neither enamel bleaching nor the photopolymerization source used had any influence on enamel shear bond strength.
id FUNORP-1_4ef4e4491ba1e6865f661f4aaa2411a7
oai_identifier_str oai:scielo:S0103-64402004000200009
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Influence of photopolymerization light source on enamel shear bond strength after bleachingdental bleachingdental enamelbond strengthThis study evaluated the influence of 3 different photopolymerization sources on enamel shear bond strength after bleaching with 10% carbamide peroxide. Seventy-two incisive bovine teeth were randomly divided into 6 groups (n=12) according to bleaching treatment and photopolymerization source used: G1 - Bleached / Halogen lamp; G2 - Not bleached / Halogen lamp (control); G3 - Bleached / Light-emitting diodes (LED); G4 - Not bleached / Light-emitting diodes (LED) (control); G5 - Bleached / Xenon plasma arc; G6 - Not bleached / Xenon plasma arc (control). Experimental groups were exposed to bleaching agent for a period of 14 days, with a daily contact of 4 h and then stored in artificial saliva at 37ºC. Control groups were stored in artificial saliva at 37ºC for same period of bleaching treatment. Procedures for bonding composite resin to enamel were carried out according to manufacturer instructions. After storage in distilled water at 37ºC for 24 hours, all samples were submitted to shear bond strength test. G2 had the highest mean value (14.86 MPa) while G5 had the lowest (12.32 MPa). The comparison of groups by 2-way ANOVA showed that there were no significant differences for either of the factors considered in this study (bleaching and photopolymerization source), hence the interaction between these factors. It was therefore possible to conclude that neither enamel bleaching nor the photopolymerization source used had any influence on enamel shear bond strength.Fundação Odontológica de Ribeirão Preto2004-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402004000200009Brazilian Dental Journal v.15 n.2 2004reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402004000200009info:eu-repo/semantics/openAccessLoretto,Sandro CordeiroBraz,RodivanLyra,Arine Maria Víveros de CastroLopes,Luís Márioeng2005-03-11T00:00:00Zoai:scielo:S0103-64402004000200009Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2005-03-11T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Influence of photopolymerization light source on enamel shear bond strength after bleaching
title Influence of photopolymerization light source on enamel shear bond strength after bleaching
spellingShingle Influence of photopolymerization light source on enamel shear bond strength after bleaching
Loretto,Sandro Cordeiro
dental bleaching
dental enamel
bond strength
title_short Influence of photopolymerization light source on enamel shear bond strength after bleaching
title_full Influence of photopolymerization light source on enamel shear bond strength after bleaching
title_fullStr Influence of photopolymerization light source on enamel shear bond strength after bleaching
title_full_unstemmed Influence of photopolymerization light source on enamel shear bond strength after bleaching
title_sort Influence of photopolymerization light source on enamel shear bond strength after bleaching
author Loretto,Sandro Cordeiro
author_facet Loretto,Sandro Cordeiro
Braz,Rodivan
Lyra,Arine Maria Víveros de Castro
Lopes,Luís Mário
author_role author
author2 Braz,Rodivan
Lyra,Arine Maria Víveros de Castro
Lopes,Luís Mário
author2_role author
author
author
dc.contributor.author.fl_str_mv Loretto,Sandro Cordeiro
Braz,Rodivan
Lyra,Arine Maria Víveros de Castro
Lopes,Luís Mário
dc.subject.por.fl_str_mv dental bleaching
dental enamel
bond strength
topic dental bleaching
dental enamel
bond strength
description This study evaluated the influence of 3 different photopolymerization sources on enamel shear bond strength after bleaching with 10% carbamide peroxide. Seventy-two incisive bovine teeth were randomly divided into 6 groups (n=12) according to bleaching treatment and photopolymerization source used: G1 - Bleached / Halogen lamp; G2 - Not bleached / Halogen lamp (control); G3 - Bleached / Light-emitting diodes (LED); G4 - Not bleached / Light-emitting diodes (LED) (control); G5 - Bleached / Xenon plasma arc; G6 - Not bleached / Xenon plasma arc (control). Experimental groups were exposed to bleaching agent for a period of 14 days, with a daily contact of 4 h and then stored in artificial saliva at 37ºC. Control groups were stored in artificial saliva at 37ºC for same period of bleaching treatment. Procedures for bonding composite resin to enamel were carried out according to manufacturer instructions. After storage in distilled water at 37ºC for 24 hours, all samples were submitted to shear bond strength test. G2 had the highest mean value (14.86 MPa) while G5 had the lowest (12.32 MPa). The comparison of groups by 2-way ANOVA showed that there were no significant differences for either of the factors considered in this study (bleaching and photopolymerization source), hence the interaction between these factors. It was therefore possible to conclude that neither enamel bleaching nor the photopolymerization source used had any influence on enamel shear bond strength.
publishDate 2004
dc.date.none.fl_str_mv 2004-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402004000200009
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402004000200009
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402004000200009
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.15 n.2 2004
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204089749602304