FiltekTM Silorane and FiltekTM Supreme XT resins: tissue reaction after subcutaneous implantation in isogenic mice

Detalhes bibliográficos
Autor(a) principal: Castañeda,Esther Ruiz De
Data de Publicação: 2011
Outros Autores: Silva,Léa A. B., Gaton-Hernández,Patrícia, Consolaro,Alberto, Rodriguez,Encarnación Gonzalez, Silva,Raquel A. B., Queiroz,Alexandra M., Nelson-Filho,Paulo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000200003
Resumo: The aim of this study was to evaluate the tissue compatibility of a silorane-based resin system (FiltekTM Silorane) and a methacrylate-based nanoparticle resin (FiltekTM Supreme XT) after implantation in the subcutaneous connective tissue of isogenic mice. One hundred and thirty five male isogenic BALB/c mice were randomly assigned to 12 experimental and 3 control groups, according to the implanted material and the experimental period of 7, 21 and 63 days. At the end of each period, the animals were killed and the tubes with the surrounding tissues were removed and processed for microscopic analysis. Samples were subjected to a descriptive and a semi-quantitative analyses using a 4-point scoring system (0-3) to evaluate the collagen fiber formation and inflammatory infiltrate. Data were statistically analyzed using the Kruskal Wallis test (?=0.05). The results showed that there was no significant difference between the experimental and control groups considering the three evaluation periods (p>0.05). The silorane-based and the methacrylate-based nanoparticle resins presented similar tissue response to that of the empty tube (control group) after subcutaneous implantation in isogenic mice.
id FUNORP-1_6cd700681830b2a5eeba7e8385090495
oai_identifier_str oai:scielo:S0103-64402011000200003
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling FiltekTM Silorane and FiltekTM Supreme XT resins: tissue reaction after subcutaneous implantation in isogenic micesubcutaneous tissuetissue reactionnanocompositenanometric particlesmathacrylate-based resinsilorane-based resinThe aim of this study was to evaluate the tissue compatibility of a silorane-based resin system (FiltekTM Silorane) and a methacrylate-based nanoparticle resin (FiltekTM Supreme XT) after implantation in the subcutaneous connective tissue of isogenic mice. One hundred and thirty five male isogenic BALB/c mice were randomly assigned to 12 experimental and 3 control groups, according to the implanted material and the experimental period of 7, 21 and 63 days. At the end of each period, the animals were killed and the tubes with the surrounding tissues were removed and processed for microscopic analysis. Samples were subjected to a descriptive and a semi-quantitative analyses using a 4-point scoring system (0-3) to evaluate the collagen fiber formation and inflammatory infiltrate. Data were statistically analyzed using the Kruskal Wallis test (?=0.05). The results showed that there was no significant difference between the experimental and control groups considering the three evaluation periods (p>0.05). The silorane-based and the methacrylate-based nanoparticle resins presented similar tissue response to that of the empty tube (control group) after subcutaneous implantation in isogenic mice.Fundação Odontológica de Ribeirão Preto2011-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000200003Brazilian Dental Journal v.22 n.2 2011reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402011000200003info:eu-repo/semantics/openAccessCastañeda,Esther Ruiz DeSilva,Léa A. B.Gaton-Hernández,PatríciaConsolaro,AlbertoRodriguez,Encarnación GonzalezSilva,Raquel A. B.Queiroz,Alexandra M.Nelson-Filho,Pauloeng2011-06-08T00:00:00Zoai:scielo:S0103-64402011000200003Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2011-06-08T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv FiltekTM Silorane and FiltekTM Supreme XT resins: tissue reaction after subcutaneous implantation in isogenic mice
title FiltekTM Silorane and FiltekTM Supreme XT resins: tissue reaction after subcutaneous implantation in isogenic mice
spellingShingle FiltekTM Silorane and FiltekTM Supreme XT resins: tissue reaction after subcutaneous implantation in isogenic mice
Castañeda,Esther Ruiz De
subcutaneous tissue
tissue reaction
nanocomposite
nanometric particles
mathacrylate-based resin
silorane-based resin
title_short FiltekTM Silorane and FiltekTM Supreme XT resins: tissue reaction after subcutaneous implantation in isogenic mice
title_full FiltekTM Silorane and FiltekTM Supreme XT resins: tissue reaction after subcutaneous implantation in isogenic mice
title_fullStr FiltekTM Silorane and FiltekTM Supreme XT resins: tissue reaction after subcutaneous implantation in isogenic mice
title_full_unstemmed FiltekTM Silorane and FiltekTM Supreme XT resins: tissue reaction after subcutaneous implantation in isogenic mice
title_sort FiltekTM Silorane and FiltekTM Supreme XT resins: tissue reaction after subcutaneous implantation in isogenic mice
author Castañeda,Esther Ruiz De
author_facet Castañeda,Esther Ruiz De
Silva,Léa A. B.
Gaton-Hernández,Patrícia
Consolaro,Alberto
Rodriguez,Encarnación Gonzalez
Silva,Raquel A. B.
Queiroz,Alexandra M.
Nelson-Filho,Paulo
author_role author
author2 Silva,Léa A. B.
Gaton-Hernández,Patrícia
Consolaro,Alberto
Rodriguez,Encarnación Gonzalez
Silva,Raquel A. B.
Queiroz,Alexandra M.
Nelson-Filho,Paulo
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Castañeda,Esther Ruiz De
Silva,Léa A. B.
Gaton-Hernández,Patrícia
Consolaro,Alberto
Rodriguez,Encarnación Gonzalez
Silva,Raquel A. B.
Queiroz,Alexandra M.
Nelson-Filho,Paulo
dc.subject.por.fl_str_mv subcutaneous tissue
tissue reaction
nanocomposite
nanometric particles
mathacrylate-based resin
silorane-based resin
topic subcutaneous tissue
tissue reaction
nanocomposite
nanometric particles
mathacrylate-based resin
silorane-based resin
description The aim of this study was to evaluate the tissue compatibility of a silorane-based resin system (FiltekTM Silorane) and a methacrylate-based nanoparticle resin (FiltekTM Supreme XT) after implantation in the subcutaneous connective tissue of isogenic mice. One hundred and thirty five male isogenic BALB/c mice were randomly assigned to 12 experimental and 3 control groups, according to the implanted material and the experimental period of 7, 21 and 63 days. At the end of each period, the animals were killed and the tubes with the surrounding tissues were removed and processed for microscopic analysis. Samples were subjected to a descriptive and a semi-quantitative analyses using a 4-point scoring system (0-3) to evaluate the collagen fiber formation and inflammatory infiltrate. Data were statistically analyzed using the Kruskal Wallis test (?=0.05). The results showed that there was no significant difference between the experimental and control groups considering the three evaluation periods (p>0.05). The silorane-based and the methacrylate-based nanoparticle resins presented similar tissue response to that of the empty tube (control group) after subcutaneous implantation in isogenic mice.
publishDate 2011
dc.date.none.fl_str_mv 2011-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000200003
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000200003
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402011000200003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.22 n.2 2011
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204091718828032