Assessment of Marginal Bone Loss around Platform-Matched and Platform-Switched Implants - A Prospective Study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Dental Journal |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402016000600712 |
Resumo: | Abstract The aim of the present study was to perform a software-assisted radiographic assessment of the effect of platform-switching on marginal bone loss (MBL) around dental implants. Forty patients requiring a dental implant in non-grafted partially edentulous mandibles were enrolled and categorized into implants receiving a platform-matched abutment (control group) or implants with a platform-switched abutment (test group). Standardized digital periapical radiographs were taken at the time of implant placement (T0), at implant loading (T1) and 1-year after functional loading (T2). Software-assisted radiographic assessment of the MBL horizontal, vertical and area changes was performed and compared between time intervals (T1-T0, T2-T1 and T2-T0). Mean radiographic horizontal MBL (hMBL) and vertical MBL (vMBL) from implant placement to 1-year after implant loading (T2-T0) were significantly increased around platform-matched when compared to platform-switched abutments (1.04 mm vs 0.84 mm, p<0.05) and (0.99 mm vs 0.82 mm, p<0.05), respectively. Additionally, bone loss area (BLa) was greater (0.77 mm2 vs 0.63 mm2; p<0.05) for platform-matched compared to platform-switched abutments. Platform-switching has a positive impact upon the amount of bone modeling after loading implants with internal hexagon connection. |
id |
FUNORP-1_7bcbf1a9aa21ed786509adfc0a0ebc26 |
---|---|
oai_identifier_str |
oai:scielo:S0103-64402016000600712 |
network_acronym_str |
FUNORP-1 |
network_name_str |
Brazilian Dental Journal |
repository_id_str |
|
spelling |
Assessment of Marginal Bone Loss around Platform-Matched and Platform-Switched Implants - A Prospective Studydental implantplatform switchingmarginal bone lossdigital radiographyAbstract The aim of the present study was to perform a software-assisted radiographic assessment of the effect of platform-switching on marginal bone loss (MBL) around dental implants. Forty patients requiring a dental implant in non-grafted partially edentulous mandibles were enrolled and categorized into implants receiving a platform-matched abutment (control group) or implants with a platform-switched abutment (test group). Standardized digital periapical radiographs were taken at the time of implant placement (T0), at implant loading (T1) and 1-year after functional loading (T2). Software-assisted radiographic assessment of the MBL horizontal, vertical and area changes was performed and compared between time intervals (T1-T0, T2-T1 and T2-T0). Mean radiographic horizontal MBL (hMBL) and vertical MBL (vMBL) from implant placement to 1-year after implant loading (T2-T0) were significantly increased around platform-matched when compared to platform-switched abutments (1.04 mm vs 0.84 mm, p<0.05) and (0.99 mm vs 0.82 mm, p<0.05), respectively. Additionally, bone loss area (BLa) was greater (0.77 mm2 vs 0.63 mm2; p<0.05) for platform-matched compared to platform-switched abutments. Platform-switching has a positive impact upon the amount of bone modeling after loading implants with internal hexagon connection.Fundação Odontológica de Ribeirão Preto2016-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402016000600712Brazilian Dental Journal v.27 n.6 2016reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440201601160info:eu-repo/semantics/openAccessSesma,NewtonGaraicoa-Pazmino,CarlosZanardi,Piero R.Chun,Eliseo P.Laganá,Dalva Cruzeng2016-12-09T00:00:00Zoai:scielo:S0103-64402016000600712Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2016-12-09T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false |
dc.title.none.fl_str_mv |
Assessment of Marginal Bone Loss around Platform-Matched and Platform-Switched Implants - A Prospective Study |
title |
Assessment of Marginal Bone Loss around Platform-Matched and Platform-Switched Implants - A Prospective Study |
spellingShingle |
Assessment of Marginal Bone Loss around Platform-Matched and Platform-Switched Implants - A Prospective Study Sesma,Newton dental implant platform switching marginal bone loss digital radiography |
title_short |
Assessment of Marginal Bone Loss around Platform-Matched and Platform-Switched Implants - A Prospective Study |
title_full |
Assessment of Marginal Bone Loss around Platform-Matched and Platform-Switched Implants - A Prospective Study |
title_fullStr |
Assessment of Marginal Bone Loss around Platform-Matched and Platform-Switched Implants - A Prospective Study |
title_full_unstemmed |
Assessment of Marginal Bone Loss around Platform-Matched and Platform-Switched Implants - A Prospective Study |
title_sort |
Assessment of Marginal Bone Loss around Platform-Matched and Platform-Switched Implants - A Prospective Study |
author |
Sesma,Newton |
author_facet |
Sesma,Newton Garaicoa-Pazmino,Carlos Zanardi,Piero R. Chun,Eliseo P. Laganá,Dalva Cruz |
author_role |
author |
author2 |
Garaicoa-Pazmino,Carlos Zanardi,Piero R. Chun,Eliseo P. Laganá,Dalva Cruz |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Sesma,Newton Garaicoa-Pazmino,Carlos Zanardi,Piero R. Chun,Eliseo P. Laganá,Dalva Cruz |
dc.subject.por.fl_str_mv |
dental implant platform switching marginal bone loss digital radiography |
topic |
dental implant platform switching marginal bone loss digital radiography |
description |
Abstract The aim of the present study was to perform a software-assisted radiographic assessment of the effect of platform-switching on marginal bone loss (MBL) around dental implants. Forty patients requiring a dental implant in non-grafted partially edentulous mandibles were enrolled and categorized into implants receiving a platform-matched abutment (control group) or implants with a platform-switched abutment (test group). Standardized digital periapical radiographs were taken at the time of implant placement (T0), at implant loading (T1) and 1-year after functional loading (T2). Software-assisted radiographic assessment of the MBL horizontal, vertical and area changes was performed and compared between time intervals (T1-T0, T2-T1 and T2-T0). Mean radiographic horizontal MBL (hMBL) and vertical MBL (vMBL) from implant placement to 1-year after implant loading (T2-T0) were significantly increased around platform-matched when compared to platform-switched abutments (1.04 mm vs 0.84 mm, p<0.05) and (0.99 mm vs 0.82 mm, p<0.05), respectively. Additionally, bone loss area (BLa) was greater (0.77 mm2 vs 0.63 mm2; p<0.05) for platform-matched compared to platform-switched abutments. Platform-switching has a positive impact upon the amount of bone modeling after loading implants with internal hexagon connection. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402016000600712 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402016000600712 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0103-6440201601160 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
dc.source.none.fl_str_mv |
Brazilian Dental Journal v.27 n.6 2016 reponame:Brazilian Dental Journal instname:Fundação Odontológica de Ribeirão Preto (FUNORP) instacron:FUNORP |
instname_str |
Fundação Odontológica de Ribeirão Preto (FUNORP) |
instacron_str |
FUNORP |
institution |
FUNORP |
reponame_str |
Brazilian Dental Journal |
collection |
Brazilian Dental Journal |
repository.name.fl_str_mv |
Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP) |
repository.mail.fl_str_mv |
bdj@forp.usp.br||sergio@fosjc.unesp.br |
_version_ |
1754204094417862656 |