Inorganic particle analysis of dental impression elastomers

Detalhes bibliográficos
Autor(a) principal: Carlo,Hugo Lemes
Data de Publicação: 2010
Outros Autores: Fonseca,Rodrigo Borges, Soares,Carlos José, Correr,Américo Bortolazzo, Correr-Sobrinho,Lourenço, Sinhoreti,Mário Alexandre Coelho
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402010000600007
Resumo: The aim of this study was to determine quantitatively and qualitatively the inorganic particle fraction of commercially available dental elastomers. The inorganic volumetric fraction of two addition silicones (Reprosil Putty/Fluid and Flexitime Easy Putty/Fluid), three condensation silicones (Clonage Putty/Fluid, Optosil Confort/Xantopren VL and Silon APS Putty/Fluid), one polyether (Impregum Soft Light Body) and one polysulfide (Permlastic Light Body) was accessed by weighing a previously determined mass of each material in water before and after burning samples at 600ºC, during 3 h. Unsettled material samples were soaked in acetone and chloroform for removal of tthe organic portion. The remaining filler particles were sputter-coated with gold evaluation of their morphology and size, under scanning electron microscopy (SEM). Flexitime Easy Putty was the material with the highest results for volumetric particle fraction, while Impregum Soft had the lowest values. Silon 2 APS Fluid presented the lowest mean filler size values, while Clonage Putty had the highest values. SEM micrographs of the inorganic particles showed several morphologies - lathe-cut, spherical, spherical-like, sticks, and sticks mixed to lathe-cut powder. The results of this study revealed differences in particle characteristics among the elastometic materials that could lead to different results when testing mechanical properties.
id FUNORP-1_88a60b0f3a8d2a6b33a9c1e9f09f929f
oai_identifier_str oai:scielo:S0103-64402010000600007
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Inorganic particle analysis of dental impression elastomersDental impression materialsscanning electron microscopyfillerThe aim of this study was to determine quantitatively and qualitatively the inorganic particle fraction of commercially available dental elastomers. The inorganic volumetric fraction of two addition silicones (Reprosil Putty/Fluid and Flexitime Easy Putty/Fluid), three condensation silicones (Clonage Putty/Fluid, Optosil Confort/Xantopren VL and Silon APS Putty/Fluid), one polyether (Impregum Soft Light Body) and one polysulfide (Permlastic Light Body) was accessed by weighing a previously determined mass of each material in water before and after burning samples at 600ºC, during 3 h. Unsettled material samples were soaked in acetone and chloroform for removal of tthe organic portion. The remaining filler particles were sputter-coated with gold evaluation of their morphology and size, under scanning electron microscopy (SEM). Flexitime Easy Putty was the material with the highest results for volumetric particle fraction, while Impregum Soft had the lowest values. Silon 2 APS Fluid presented the lowest mean filler size values, while Clonage Putty had the highest values. SEM micrographs of the inorganic particles showed several morphologies - lathe-cut, spherical, spherical-like, sticks, and sticks mixed to lathe-cut powder. The results of this study revealed differences in particle characteristics among the elastometic materials that could lead to different results when testing mechanical properties.Fundação Odontológica de Ribeirão Preto2010-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402010000600007Brazilian Dental Journal v.21 n.6 2010reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402010000600007info:eu-repo/semantics/openAccessCarlo,Hugo LemesFonseca,Rodrigo BorgesSoares,Carlos JoséCorrer,Américo BortolazzoCorrer-Sobrinho,LourençoSinhoreti,Mário Alexandre Coelhoeng2011-01-17T00:00:00Zoai:scielo:S0103-64402010000600007Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2011-01-17T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Inorganic particle analysis of dental impression elastomers
title Inorganic particle analysis of dental impression elastomers
spellingShingle Inorganic particle analysis of dental impression elastomers
Carlo,Hugo Lemes
Dental impression materials
scanning electron microscopy
filler
title_short Inorganic particle analysis of dental impression elastomers
title_full Inorganic particle analysis of dental impression elastomers
title_fullStr Inorganic particle analysis of dental impression elastomers
title_full_unstemmed Inorganic particle analysis of dental impression elastomers
title_sort Inorganic particle analysis of dental impression elastomers
author Carlo,Hugo Lemes
author_facet Carlo,Hugo Lemes
Fonseca,Rodrigo Borges
Soares,Carlos José
Correr,Américo Bortolazzo
Correr-Sobrinho,Lourenço
Sinhoreti,Mário Alexandre Coelho
author_role author
author2 Fonseca,Rodrigo Borges
Soares,Carlos José
Correr,Américo Bortolazzo
Correr-Sobrinho,Lourenço
Sinhoreti,Mário Alexandre Coelho
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Carlo,Hugo Lemes
Fonseca,Rodrigo Borges
Soares,Carlos José
Correr,Américo Bortolazzo
Correr-Sobrinho,Lourenço
Sinhoreti,Mário Alexandre Coelho
dc.subject.por.fl_str_mv Dental impression materials
scanning electron microscopy
filler
topic Dental impression materials
scanning electron microscopy
filler
description The aim of this study was to determine quantitatively and qualitatively the inorganic particle fraction of commercially available dental elastomers. The inorganic volumetric fraction of two addition silicones (Reprosil Putty/Fluid and Flexitime Easy Putty/Fluid), three condensation silicones (Clonage Putty/Fluid, Optosil Confort/Xantopren VL and Silon APS Putty/Fluid), one polyether (Impregum Soft Light Body) and one polysulfide (Permlastic Light Body) was accessed by weighing a previously determined mass of each material in water before and after burning samples at 600ºC, during 3 h. Unsettled material samples were soaked in acetone and chloroform for removal of tthe organic portion. The remaining filler particles were sputter-coated with gold evaluation of their morphology and size, under scanning electron microscopy (SEM). Flexitime Easy Putty was the material with the highest results for volumetric particle fraction, while Impregum Soft had the lowest values. Silon 2 APS Fluid presented the lowest mean filler size values, while Clonage Putty had the highest values. SEM micrographs of the inorganic particles showed several morphologies - lathe-cut, spherical, spherical-like, sticks, and sticks mixed to lathe-cut powder. The results of this study revealed differences in particle characteristics among the elastometic materials that could lead to different results when testing mechanical properties.
publishDate 2010
dc.date.none.fl_str_mv 2010-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402010000600007
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402010000600007
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402010000600007
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.21 n.6 2010
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204091678982144