Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law

Detalhes bibliográficos
Autor(a) principal: Rocha,Mateus Garcia
Data de Publicação: 2021
Outros Autores: Roulet,Jean-François, Sinhoreti,Mario Alexandre Coelho, Correr,Américo Bortolazzo, Oliveira,Dayane
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402021000100078
Resumo: Abstract The objective of this study was to evaluate the effect of the exposure reciprocity law of a multi-wave light-emitting diode (LED) on the light transmittance (LT), depth of cure (DOC) and degree of conversion in-depth (DC) of a bulk fill composite. A bulk fill composite (EvoCeram® bulk fill, Ivoclar Vivadent) was photoactivated using the multi-wave LED (VALO™ Cordless, Ultradent). The LED was previously characterized using a spectrophotometer to standardize the time of exposure when using the Standard or Xtra-Power modes with the same radiant exposure of 20J/cm2. LT was evaluated through samples of the bulk fill composite every millimeter till 4 mm in-depth. DOC was evaluated according to the ISO 4049. DC of the central longitudinal cross-section from each sample of the DOC test was mapped using FT-NIR microscopy. Data were statistically analyzed according to the experimental design (α=0.05; ß=0.2). The radiant exposure in the violet wavelength range for Standard and Xtra-Power was 4.5 and 5.0 J/cm2, respectively; for the blue wavelength range the radiant exposure for Standard and Xtra-Power was 15.5 and 15.0 J/cm2, respectively. There was no statistical difference in the DOC using Standard or Xtra-Power light-curing modes, but the DOC was lower than the claimed by the manufacturer (4 mm). The DC was not significantly affected by the light-curing mode up to 4 mm in depth (p>0.05). According to exposure reciprocity law, the reduction in exposure time using the same radiant exposure did not affect the depth of cure of the bulk fill composite.
id FUNORP-1_9792852aa874f9ce3ed0c2265532c4ea
oai_identifier_str oai:scielo:S0103-64402021000100078
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity LawCQcamphorquinoneTPOmono-alkyl phosphinedegree of conversionAbstract The objective of this study was to evaluate the effect of the exposure reciprocity law of a multi-wave light-emitting diode (LED) on the light transmittance (LT), depth of cure (DOC) and degree of conversion in-depth (DC) of a bulk fill composite. A bulk fill composite (EvoCeram® bulk fill, Ivoclar Vivadent) was photoactivated using the multi-wave LED (VALO™ Cordless, Ultradent). The LED was previously characterized using a spectrophotometer to standardize the time of exposure when using the Standard or Xtra-Power modes with the same radiant exposure of 20J/cm2. LT was evaluated through samples of the bulk fill composite every millimeter till 4 mm in-depth. DOC was evaluated according to the ISO 4049. DC of the central longitudinal cross-section from each sample of the DOC test was mapped using FT-NIR microscopy. Data were statistically analyzed according to the experimental design (α=0.05; ß=0.2). The radiant exposure in the violet wavelength range for Standard and Xtra-Power was 4.5 and 5.0 J/cm2, respectively; for the blue wavelength range the radiant exposure for Standard and Xtra-Power was 15.5 and 15.0 J/cm2, respectively. There was no statistical difference in the DOC using Standard or Xtra-Power light-curing modes, but the DOC was lower than the claimed by the manufacturer (4 mm). The DC was not significantly affected by the light-curing mode up to 4 mm in depth (p>0.05). According to exposure reciprocity law, the reduction in exposure time using the same radiant exposure did not affect the depth of cure of the bulk fill composite.Fundação Odontológica de Ribeirão Preto2021-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402021000100078Brazilian Dental Journal v.32 n.1 2021reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440202103842info:eu-repo/semantics/openAccessRocha,Mateus GarciaRoulet,Jean-FrançoisSinhoreti,Mario Alexandre CoelhoCorrer,Américo BortolazzoOliveira,Dayaneeng2021-03-30T00:00:00Zoai:scielo:S0103-64402021000100078Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2021-03-30T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law
title Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law
spellingShingle Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law
Rocha,Mateus Garcia
CQ
camphorquinone
TPO
mono-alkyl phosphine
degree of conversion
title_short Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law
title_full Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law
title_fullStr Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law
title_full_unstemmed Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law
title_sort Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law
author Rocha,Mateus Garcia
author_facet Rocha,Mateus Garcia
Roulet,Jean-François
Sinhoreti,Mario Alexandre Coelho
Correr,Américo Bortolazzo
Oliveira,Dayane
author_role author
author2 Roulet,Jean-François
Sinhoreti,Mario Alexandre Coelho
Correr,Américo Bortolazzo
Oliveira,Dayane
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Rocha,Mateus Garcia
Roulet,Jean-François
Sinhoreti,Mario Alexandre Coelho
Correr,Américo Bortolazzo
Oliveira,Dayane
dc.subject.por.fl_str_mv CQ
camphorquinone
TPO
mono-alkyl phosphine
degree of conversion
topic CQ
camphorquinone
TPO
mono-alkyl phosphine
degree of conversion
description Abstract The objective of this study was to evaluate the effect of the exposure reciprocity law of a multi-wave light-emitting diode (LED) on the light transmittance (LT), depth of cure (DOC) and degree of conversion in-depth (DC) of a bulk fill composite. A bulk fill composite (EvoCeram® bulk fill, Ivoclar Vivadent) was photoactivated using the multi-wave LED (VALO™ Cordless, Ultradent). The LED was previously characterized using a spectrophotometer to standardize the time of exposure when using the Standard or Xtra-Power modes with the same radiant exposure of 20J/cm2. LT was evaluated through samples of the bulk fill composite every millimeter till 4 mm in-depth. DOC was evaluated according to the ISO 4049. DC of the central longitudinal cross-section from each sample of the DOC test was mapped using FT-NIR microscopy. Data were statistically analyzed according to the experimental design (α=0.05; ß=0.2). The radiant exposure in the violet wavelength range for Standard and Xtra-Power was 4.5 and 5.0 J/cm2, respectively; for the blue wavelength range the radiant exposure for Standard and Xtra-Power was 15.5 and 15.0 J/cm2, respectively. There was no statistical difference in the DOC using Standard or Xtra-Power light-curing modes, but the DOC was lower than the claimed by the manufacturer (4 mm). The DC was not significantly affected by the light-curing mode up to 4 mm in depth (p>0.05). According to exposure reciprocity law, the reduction in exposure time using the same radiant exposure did not affect the depth of cure of the bulk fill composite.
publishDate 2021
dc.date.none.fl_str_mv 2021-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402021000100078
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402021000100078
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0103-6440202103842
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.32 n.1 2021
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204096209879040