Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Dental Journal |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402021000100078 |
Resumo: | Abstract The objective of this study was to evaluate the effect of the exposure reciprocity law of a multi-wave light-emitting diode (LED) on the light transmittance (LT), depth of cure (DOC) and degree of conversion in-depth (DC) of a bulk fill composite. A bulk fill composite (EvoCeram® bulk fill, Ivoclar Vivadent) was photoactivated using the multi-wave LED (VALO™ Cordless, Ultradent). The LED was previously characterized using a spectrophotometer to standardize the time of exposure when using the Standard or Xtra-Power modes with the same radiant exposure of 20J/cm2. LT was evaluated through samples of the bulk fill composite every millimeter till 4 mm in-depth. DOC was evaluated according to the ISO 4049. DC of the central longitudinal cross-section from each sample of the DOC test was mapped using FT-NIR microscopy. Data were statistically analyzed according to the experimental design (α=0.05; ß=0.2). The radiant exposure in the violet wavelength range for Standard and Xtra-Power was 4.5 and 5.0 J/cm2, respectively; for the blue wavelength range the radiant exposure for Standard and Xtra-Power was 15.5 and 15.0 J/cm2, respectively. There was no statistical difference in the DOC using Standard or Xtra-Power light-curing modes, but the DOC was lower than the claimed by the manufacturer (4 mm). The DC was not significantly affected by the light-curing mode up to 4 mm in depth (p>0.05). According to exposure reciprocity law, the reduction in exposure time using the same radiant exposure did not affect the depth of cure of the bulk fill composite. |
id |
FUNORP-1_9792852aa874f9ce3ed0c2265532c4ea |
---|---|
oai_identifier_str |
oai:scielo:S0103-64402021000100078 |
network_acronym_str |
FUNORP-1 |
network_name_str |
Brazilian Dental Journal |
repository_id_str |
|
spelling |
Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity LawCQcamphorquinoneTPOmono-alkyl phosphinedegree of conversionAbstract The objective of this study was to evaluate the effect of the exposure reciprocity law of a multi-wave light-emitting diode (LED) on the light transmittance (LT), depth of cure (DOC) and degree of conversion in-depth (DC) of a bulk fill composite. A bulk fill composite (EvoCeram® bulk fill, Ivoclar Vivadent) was photoactivated using the multi-wave LED (VALO™ Cordless, Ultradent). The LED was previously characterized using a spectrophotometer to standardize the time of exposure when using the Standard or Xtra-Power modes with the same radiant exposure of 20J/cm2. LT was evaluated through samples of the bulk fill composite every millimeter till 4 mm in-depth. DOC was evaluated according to the ISO 4049. DC of the central longitudinal cross-section from each sample of the DOC test was mapped using FT-NIR microscopy. Data were statistically analyzed according to the experimental design (α=0.05; ß=0.2). The radiant exposure in the violet wavelength range for Standard and Xtra-Power was 4.5 and 5.0 J/cm2, respectively; for the blue wavelength range the radiant exposure for Standard and Xtra-Power was 15.5 and 15.0 J/cm2, respectively. There was no statistical difference in the DOC using Standard or Xtra-Power light-curing modes, but the DOC was lower than the claimed by the manufacturer (4 mm). The DC was not significantly affected by the light-curing mode up to 4 mm in depth (p>0.05). According to exposure reciprocity law, the reduction in exposure time using the same radiant exposure did not affect the depth of cure of the bulk fill composite.Fundação Odontológica de Ribeirão Preto2021-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402021000100078Brazilian Dental Journal v.32 n.1 2021reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440202103842info:eu-repo/semantics/openAccessRocha,Mateus GarciaRoulet,Jean-FrançoisSinhoreti,Mario Alexandre CoelhoCorrer,Américo BortolazzoOliveira,Dayaneeng2021-03-30T00:00:00Zoai:scielo:S0103-64402021000100078Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2021-03-30T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false |
dc.title.none.fl_str_mv |
Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law |
title |
Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law |
spellingShingle |
Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law Rocha,Mateus Garcia CQ camphorquinone TPO mono-alkyl phosphine degree of conversion |
title_short |
Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law |
title_full |
Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law |
title_fullStr |
Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law |
title_full_unstemmed |
Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law |
title_sort |
Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law |
author |
Rocha,Mateus Garcia |
author_facet |
Rocha,Mateus Garcia Roulet,Jean-François Sinhoreti,Mario Alexandre Coelho Correr,Américo Bortolazzo Oliveira,Dayane |
author_role |
author |
author2 |
Roulet,Jean-François Sinhoreti,Mario Alexandre Coelho Correr,Américo Bortolazzo Oliveira,Dayane |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Rocha,Mateus Garcia Roulet,Jean-François Sinhoreti,Mario Alexandre Coelho Correr,Américo Bortolazzo Oliveira,Dayane |
dc.subject.por.fl_str_mv |
CQ camphorquinone TPO mono-alkyl phosphine degree of conversion |
topic |
CQ camphorquinone TPO mono-alkyl phosphine degree of conversion |
description |
Abstract The objective of this study was to evaluate the effect of the exposure reciprocity law of a multi-wave light-emitting diode (LED) on the light transmittance (LT), depth of cure (DOC) and degree of conversion in-depth (DC) of a bulk fill composite. A bulk fill composite (EvoCeram® bulk fill, Ivoclar Vivadent) was photoactivated using the multi-wave LED (VALO™ Cordless, Ultradent). The LED was previously characterized using a spectrophotometer to standardize the time of exposure when using the Standard or Xtra-Power modes with the same radiant exposure of 20J/cm2. LT was evaluated through samples of the bulk fill composite every millimeter till 4 mm in-depth. DOC was evaluated according to the ISO 4049. DC of the central longitudinal cross-section from each sample of the DOC test was mapped using FT-NIR microscopy. Data were statistically analyzed according to the experimental design (α=0.05; ß=0.2). The radiant exposure in the violet wavelength range for Standard and Xtra-Power was 4.5 and 5.0 J/cm2, respectively; for the blue wavelength range the radiant exposure for Standard and Xtra-Power was 15.5 and 15.0 J/cm2, respectively. There was no statistical difference in the DOC using Standard or Xtra-Power light-curing modes, but the DOC was lower than the claimed by the manufacturer (4 mm). The DC was not significantly affected by the light-curing mode up to 4 mm in depth (p>0.05). According to exposure reciprocity law, the reduction in exposure time using the same radiant exposure did not affect the depth of cure of the bulk fill composite. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402021000100078 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402021000100078 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0103-6440202103842 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
dc.source.none.fl_str_mv |
Brazilian Dental Journal v.32 n.1 2021 reponame:Brazilian Dental Journal instname:Fundação Odontológica de Ribeirão Preto (FUNORP) instacron:FUNORP |
instname_str |
Fundação Odontológica de Ribeirão Preto (FUNORP) |
instacron_str |
FUNORP |
institution |
FUNORP |
reponame_str |
Brazilian Dental Journal |
collection |
Brazilian Dental Journal |
repository.name.fl_str_mv |
Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP) |
repository.mail.fl_str_mv |
bdj@forp.usp.br||sergio@fosjc.unesp.br |
_version_ |
1754204096209879040 |