Compressive strength of esthetic restorative materials polymerized with quartz-tungsten-halogen light and blue LED

Detalhes bibliográficos
Autor(a) principal: Silva,Cecy Martins
Data de Publicação: 2009
Outros Autores: Dias,Katia Regina Hostilio Cervantes
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000100009
Resumo: This study compared the compressive strength of a composite resin and compomer photoactivated with a conventional quartz-tungsten halogen-light (XL 3000, 3M/SPE) and a blue light-emitting diode (LED) (SmartLite PS; Dentsply/De Trey). Forty disc-shaped specimens were prepared using a split polytetrafluoroethylene matrix (4.0 mm diameter x 8.0 mm hight) in which the materials were inserted incrementally. The curing time of each increment was of 40 s with the QTH and 10 s with the LED. The specimens were randomly assigned to 4 groups (n=10), according to the light source and the restorative material. After storage in distilled water at 37oC ± 2oC for 24 h, the specimens was tested in compressive strength in a universal testing machine with load cell of 500 kgf running at a crosshead speed of 0.5 mm/min. Data (in MPa) were analyzed statistically by ANOVA and Student-Newman-Keuls test (p<0.05). For the composite resin, light curing with the QTH source did not produce statistically significant difference (p>0.05) in the compressive strength when compared to light curing with the LED source. However, light curing of the compomer with the QTH source resulted in significantly higher compressive strength than the use of the LED unit (p>0.05). The composite resin presented significantly higher (p>0.05) compressive strength than the compomer, regardless of the light source. In conclusion, the compressive strength of the tested materials photoactivated with a QTH and a LED light source was influenced by the energy density employed and the chemical composition of the esthetic restorative materials.
id FUNORP-1_9fb95864e08bc0abc6845704ab9ccc9b
oai_identifier_str oai:scielo:S0103-64402009000100009
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Compressive strength of esthetic restorative materials polymerized with quartz-tungsten-halogen light and blue LEDcomposite resincompomerslight-curingLEDQTH lightThis study compared the compressive strength of a composite resin and compomer photoactivated with a conventional quartz-tungsten halogen-light (XL 3000, 3M/SPE) and a blue light-emitting diode (LED) (SmartLite PS; Dentsply/De Trey). Forty disc-shaped specimens were prepared using a split polytetrafluoroethylene matrix (4.0 mm diameter x 8.0 mm hight) in which the materials were inserted incrementally. The curing time of each increment was of 40 s with the QTH and 10 s with the LED. The specimens were randomly assigned to 4 groups (n=10), according to the light source and the restorative material. After storage in distilled water at 37oC ± 2oC for 24 h, the specimens was tested in compressive strength in a universal testing machine with load cell of 500 kgf running at a crosshead speed of 0.5 mm/min. Data (in MPa) were analyzed statistically by ANOVA and Student-Newman-Keuls test (p<0.05). For the composite resin, light curing with the QTH source did not produce statistically significant difference (p>0.05) in the compressive strength when compared to light curing with the LED source. However, light curing of the compomer with the QTH source resulted in significantly higher compressive strength than the use of the LED unit (p>0.05). The composite resin presented significantly higher (p>0.05) compressive strength than the compomer, regardless of the light source. In conclusion, the compressive strength of the tested materials photoactivated with a QTH and a LED light source was influenced by the energy density employed and the chemical composition of the esthetic restorative materials.Fundação Odontológica de Ribeirão Preto2009-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000100009Brazilian Dental Journal v.20 n.1 2009reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402009000100009info:eu-repo/semantics/openAccessSilva,Cecy MartinsDias,Katia Regina Hostilio Cervanteseng2009-05-21T00:00:00Zoai:scielo:S0103-64402009000100009Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2009-05-21T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Compressive strength of esthetic restorative materials polymerized with quartz-tungsten-halogen light and blue LED
title Compressive strength of esthetic restorative materials polymerized with quartz-tungsten-halogen light and blue LED
spellingShingle Compressive strength of esthetic restorative materials polymerized with quartz-tungsten-halogen light and blue LED
Silva,Cecy Martins
composite resin
compomers
light-curing
LED
QTH light
title_short Compressive strength of esthetic restorative materials polymerized with quartz-tungsten-halogen light and blue LED
title_full Compressive strength of esthetic restorative materials polymerized with quartz-tungsten-halogen light and blue LED
title_fullStr Compressive strength of esthetic restorative materials polymerized with quartz-tungsten-halogen light and blue LED
title_full_unstemmed Compressive strength of esthetic restorative materials polymerized with quartz-tungsten-halogen light and blue LED
title_sort Compressive strength of esthetic restorative materials polymerized with quartz-tungsten-halogen light and blue LED
author Silva,Cecy Martins
author_facet Silva,Cecy Martins
Dias,Katia Regina Hostilio Cervantes
author_role author
author2 Dias,Katia Regina Hostilio Cervantes
author2_role author
dc.contributor.author.fl_str_mv Silva,Cecy Martins
Dias,Katia Regina Hostilio Cervantes
dc.subject.por.fl_str_mv composite resin
compomers
light-curing
LED
QTH light
topic composite resin
compomers
light-curing
LED
QTH light
description This study compared the compressive strength of a composite resin and compomer photoactivated with a conventional quartz-tungsten halogen-light (XL 3000, 3M/SPE) and a blue light-emitting diode (LED) (SmartLite PS; Dentsply/De Trey). Forty disc-shaped specimens were prepared using a split polytetrafluoroethylene matrix (4.0 mm diameter x 8.0 mm hight) in which the materials were inserted incrementally. The curing time of each increment was of 40 s with the QTH and 10 s with the LED. The specimens were randomly assigned to 4 groups (n=10), according to the light source and the restorative material. After storage in distilled water at 37oC ± 2oC for 24 h, the specimens was tested in compressive strength in a universal testing machine with load cell of 500 kgf running at a crosshead speed of 0.5 mm/min. Data (in MPa) were analyzed statistically by ANOVA and Student-Newman-Keuls test (p<0.05). For the composite resin, light curing with the QTH source did not produce statistically significant difference (p>0.05) in the compressive strength when compared to light curing with the LED source. However, light curing of the compomer with the QTH source resulted in significantly higher compressive strength than the use of the LED unit (p>0.05). The composite resin presented significantly higher (p>0.05) compressive strength than the compomer, regardless of the light source. In conclusion, the compressive strength of the tested materials photoactivated with a QTH and a LED light source was influenced by the energy density employed and the chemical composition of the esthetic restorative materials.
publishDate 2009
dc.date.none.fl_str_mv 2009-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000100009
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000100009
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402009000100009
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.20 n.1 2009
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204090935541760