Influence of casting methods on marginal and internal discrepancies of complete cast crowns

Detalhes bibliográficos
Autor(a) principal: Milan,Fábio Machado
Data de Publicação: 2004
Outros Autores: Consani,Simonides, Correr Sobrinho,Lourenço, Sinhoreti,Mario Alexandre Coelho, Sousa-Neto,Manoel D., Knowles,Jonathan C.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402004000200008
Resumo: The relationship between the application of die-spacer prior to wax pattern fabrication and metal removal from the inner surface of the casting on marginal and internal discrepancies of complete cast crowns was evaluated. One hundred and twenty complete crowns were cast with palladium-silver alloy melted by gas-oxygen torch or electrical resistance and cast with a centrifuge casting machine. After casting, the crowns were seated on each type of different marginal configuration dies (90-degree shoulder, 20-degree beveled shoulder, and 45-degree chamfered shoulder) with a static load of 90 N during 1 min. Evaluation of the marginal fit of the specimens was made using a digital micrometer. The crowns were embedded in acrylic resin and longitudinally sectioned to verify the internal discrepancy that occurred in lateral and occlusal interfaces with a digital micrometer. The data were submitted to ANOVA and Tukey's test with a significance level of 5%. The best marginal and inner fits were obtained with the gas-oxygen torch source. The 45-degree chamfered shoulder showed the best marginal and inner fit, and better internal relief was obtained in the crowns abraded with 50 µm Al2O3 particles.
id FUNORP-1_b0d26d35ea6e7ae61bd3fa08018a8a1e
oai_identifier_str oai:scielo:S0103-64402004000200008
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Influence of casting methods on marginal and internal discrepancies of complete cast crownsdental alloycasting techniquesmarginal discrepancyThe relationship between the application of die-spacer prior to wax pattern fabrication and metal removal from the inner surface of the casting on marginal and internal discrepancies of complete cast crowns was evaluated. One hundred and twenty complete crowns were cast with palladium-silver alloy melted by gas-oxygen torch or electrical resistance and cast with a centrifuge casting machine. After casting, the crowns were seated on each type of different marginal configuration dies (90-degree shoulder, 20-degree beveled shoulder, and 45-degree chamfered shoulder) with a static load of 90 N during 1 min. Evaluation of the marginal fit of the specimens was made using a digital micrometer. The crowns were embedded in acrylic resin and longitudinally sectioned to verify the internal discrepancy that occurred in lateral and occlusal interfaces with a digital micrometer. The data were submitted to ANOVA and Tukey's test with a significance level of 5%. The best marginal and inner fits were obtained with the gas-oxygen torch source. The 45-degree chamfered shoulder showed the best marginal and inner fit, and better internal relief was obtained in the crowns abraded with 50 µm Al2O3 particles.Fundação Odontológica de Ribeirão Preto2004-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402004000200008Brazilian Dental Journal v.15 n.2 2004reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402004000200008info:eu-repo/semantics/openAccessMilan,Fábio MachadoConsani,SimonidesCorrer Sobrinho,LourençoSinhoreti,Mario Alexandre CoelhoSousa-Neto,Manoel D.Knowles,Jonathan C.eng2005-03-11T00:00:00Zoai:scielo:S0103-64402004000200008Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2005-03-11T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Influence of casting methods on marginal and internal discrepancies of complete cast crowns
title Influence of casting methods on marginal and internal discrepancies of complete cast crowns
spellingShingle Influence of casting methods on marginal and internal discrepancies of complete cast crowns
Milan,Fábio Machado
dental alloy
casting techniques
marginal discrepancy
title_short Influence of casting methods on marginal and internal discrepancies of complete cast crowns
title_full Influence of casting methods on marginal and internal discrepancies of complete cast crowns
title_fullStr Influence of casting methods on marginal and internal discrepancies of complete cast crowns
title_full_unstemmed Influence of casting methods on marginal and internal discrepancies of complete cast crowns
title_sort Influence of casting methods on marginal and internal discrepancies of complete cast crowns
author Milan,Fábio Machado
author_facet Milan,Fábio Machado
Consani,Simonides
Correr Sobrinho,Lourenço
Sinhoreti,Mario Alexandre Coelho
Sousa-Neto,Manoel D.
Knowles,Jonathan C.
author_role author
author2 Consani,Simonides
Correr Sobrinho,Lourenço
Sinhoreti,Mario Alexandre Coelho
Sousa-Neto,Manoel D.
Knowles,Jonathan C.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Milan,Fábio Machado
Consani,Simonides
Correr Sobrinho,Lourenço
Sinhoreti,Mario Alexandre Coelho
Sousa-Neto,Manoel D.
Knowles,Jonathan C.
dc.subject.por.fl_str_mv dental alloy
casting techniques
marginal discrepancy
topic dental alloy
casting techniques
marginal discrepancy
description The relationship between the application of die-spacer prior to wax pattern fabrication and metal removal from the inner surface of the casting on marginal and internal discrepancies of complete cast crowns was evaluated. One hundred and twenty complete crowns were cast with palladium-silver alloy melted by gas-oxygen torch or electrical resistance and cast with a centrifuge casting machine. After casting, the crowns were seated on each type of different marginal configuration dies (90-degree shoulder, 20-degree beveled shoulder, and 45-degree chamfered shoulder) with a static load of 90 N during 1 min. Evaluation of the marginal fit of the specimens was made using a digital micrometer. The crowns were embedded in acrylic resin and longitudinally sectioned to verify the internal discrepancy that occurred in lateral and occlusal interfaces with a digital micrometer. The data were submitted to ANOVA and Tukey's test with a significance level of 5%. The best marginal and inner fits were obtained with the gas-oxygen torch source. The 45-degree chamfered shoulder showed the best marginal and inner fit, and better internal relief was obtained in the crowns abraded with 50 µm Al2O3 particles.
publishDate 2004
dc.date.none.fl_str_mv 2004-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402004000200008
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402004000200008
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402004000200008
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.15 n.2 2004
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204089748553728