Effect of etching time and light source on the bond strength of metallic brackets to ceramic
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Dental Journal |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000300011 |
Resumo: | This study evaluated the bond strength of brackets to ceramic testing different etching times and light sources for photo-activation of the bonding agent. Cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 20 or 60 s. After application of silane on the ceramic surface, metallic brackets were bonded to the cylinders using Transbond XT (3M Unitek). The specimens for each etching time were assigned to 4 groups (n=15), according to the light source: XL2500 halogen light, UltraLume 5 LED, AccuCure 3000 argon laser, and Apollo 95E plasma arc. Light-activation was carried out with total exposure times of 40, 40, 20 and 12 s, respectively. Shear strength testing was carried out after 24 h. The adhesive remnant index (ARI) was evaluated under magnification. Data were subjected to two-way ANOVA and Tukey's test (α=0.05). Specimens etched for 20 s presented significantly lower bond strength (p<0.05) compared with those etched for 60 s. No significant differences (p>0.05) were detected among the light sources. The ARI showed a predominance of scores 0 in all groups, with an increase in scores 1, 2 and 3 for the 60 s time. In conclusion, only the etching time had significant influence on the bond strength of brackets to ceramic. |
id |
FUNORP-1_b30be919a7d5bd8fc3d2452528e757ed |
---|---|
oai_identifier_str |
oai:scielo:S0103-64402011000300011 |
network_acronym_str |
FUNORP-1 |
network_name_str |
Brazilian Dental Journal |
repository_id_str |
|
spelling |
Effect of etching time and light source on the bond strength of metallic brackets to ceramicbondingceramicetching timelight sourceshear bond strengthThis study evaluated the bond strength of brackets to ceramic testing different etching times and light sources for photo-activation of the bonding agent. Cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 20 or 60 s. After application of silane on the ceramic surface, metallic brackets were bonded to the cylinders using Transbond XT (3M Unitek). The specimens for each etching time were assigned to 4 groups (n=15), according to the light source: XL2500 halogen light, UltraLume 5 LED, AccuCure 3000 argon laser, and Apollo 95E plasma arc. Light-activation was carried out with total exposure times of 40, 40, 20 and 12 s, respectively. Shear strength testing was carried out after 24 h. The adhesive remnant index (ARI) was evaluated under magnification. Data were subjected to two-way ANOVA and Tukey's test (α=0.05). Specimens etched for 20 s presented significantly lower bond strength (p<0.05) compared with those etched for 60 s. No significant differences (p>0.05) were detected among the light sources. The ARI showed a predominance of scores 0 in all groups, with an increase in scores 1, 2 and 3 for the 60 s time. In conclusion, only the etching time had significant influence on the bond strength of brackets to ceramic.Fundação Odontológica de Ribeirão Preto2011-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000300011Brazilian Dental Journal v.22 n.3 2011reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402011000300011info:eu-repo/semantics/openAccessGonçalves,Paulo Roberto AmaralMoraes,Rafael Ratto deCosta,Ana RosaCorrer,Américo BortolazzoNouer,Paulo Roberto AranhaSinhoreti,Mário Alexandre CoelhoCorrer-Sobrinho,Lourençoeng2011-06-10T00:00:00Zoai:scielo:S0103-64402011000300011Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2011-06-10T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false |
dc.title.none.fl_str_mv |
Effect of etching time and light source on the bond strength of metallic brackets to ceramic |
title |
Effect of etching time and light source on the bond strength of metallic brackets to ceramic |
spellingShingle |
Effect of etching time and light source on the bond strength of metallic brackets to ceramic Gonçalves,Paulo Roberto Amaral bonding ceramic etching time light source shear bond strength |
title_short |
Effect of etching time and light source on the bond strength of metallic brackets to ceramic |
title_full |
Effect of etching time and light source on the bond strength of metallic brackets to ceramic |
title_fullStr |
Effect of etching time and light source on the bond strength of metallic brackets to ceramic |
title_full_unstemmed |
Effect of etching time and light source on the bond strength of metallic brackets to ceramic |
title_sort |
Effect of etching time and light source on the bond strength of metallic brackets to ceramic |
author |
Gonçalves,Paulo Roberto Amaral |
author_facet |
Gonçalves,Paulo Roberto Amaral Moraes,Rafael Ratto de Costa,Ana Rosa Correr,Américo Bortolazzo Nouer,Paulo Roberto Aranha Sinhoreti,Mário Alexandre Coelho Correr-Sobrinho,Lourenço |
author_role |
author |
author2 |
Moraes,Rafael Ratto de Costa,Ana Rosa Correr,Américo Bortolazzo Nouer,Paulo Roberto Aranha Sinhoreti,Mário Alexandre Coelho Correr-Sobrinho,Lourenço |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Gonçalves,Paulo Roberto Amaral Moraes,Rafael Ratto de Costa,Ana Rosa Correr,Américo Bortolazzo Nouer,Paulo Roberto Aranha Sinhoreti,Mário Alexandre Coelho Correr-Sobrinho,Lourenço |
dc.subject.por.fl_str_mv |
bonding ceramic etching time light source shear bond strength |
topic |
bonding ceramic etching time light source shear bond strength |
description |
This study evaluated the bond strength of brackets to ceramic testing different etching times and light sources for photo-activation of the bonding agent. Cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 20 or 60 s. After application of silane on the ceramic surface, metallic brackets were bonded to the cylinders using Transbond XT (3M Unitek). The specimens for each etching time were assigned to 4 groups (n=15), according to the light source: XL2500 halogen light, UltraLume 5 LED, AccuCure 3000 argon laser, and Apollo 95E plasma arc. Light-activation was carried out with total exposure times of 40, 40, 20 and 12 s, respectively. Shear strength testing was carried out after 24 h. The adhesive remnant index (ARI) was evaluated under magnification. Data were subjected to two-way ANOVA and Tukey's test (α=0.05). Specimens etched for 20 s presented significantly lower bond strength (p<0.05) compared with those etched for 60 s. No significant differences (p>0.05) were detected among the light sources. The ARI showed a predominance of scores 0 in all groups, with an increase in scores 1, 2 and 3 for the 60 s time. In conclusion, only the etching time had significant influence on the bond strength of brackets to ceramic. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000300011 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000300011 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-64402011000300011 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
dc.source.none.fl_str_mv |
Brazilian Dental Journal v.22 n.3 2011 reponame:Brazilian Dental Journal instname:Fundação Odontológica de Ribeirão Preto (FUNORP) instacron:FUNORP |
instname_str |
Fundação Odontológica de Ribeirão Preto (FUNORP) |
instacron_str |
FUNORP |
institution |
FUNORP |
reponame_str |
Brazilian Dental Journal |
collection |
Brazilian Dental Journal |
repository.name.fl_str_mv |
Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP) |
repository.mail.fl_str_mv |
bdj@forp.usp.br||sergio@fosjc.unesp.br |
_version_ |
1754204091781742592 |