Influence of Cusp Inclination and Type of Retention on Fracture Load of Implant-Supported Crowns

Detalhes bibliográficos
Autor(a) principal: Rocha,Cibele Oliveira de Melo
Data de Publicação: 2017
Outros Autores: Longhini,Diogo, Pereira,Rodrigo de Paula, Arioli Filho,João Neudenir
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402017000100092
Resumo: Abstract There are few informations about the influence of cusp inclination on the fracture strength of implant-supported crowns. The study aimed to evaluate the influence of cusp inclination and retention type on fracture load in implant-supported metal-ceramic single crowns. Sixty crowns were made, classified as cemented and screw-retained with screw access hole (SAH) sealed or not. Standard (33°) and reduced (20°) cusp inclinations were tested for each group (n=10). To support crowns of a mandibular second molar, analogs of external hexagon implants 5.0 were used. The fracture load was measured in a universal testing machine EMIC DL2000 (10 kN load cell; 0.5 mm/min). Two-way ANOVA (retention and cusp inclination) followed by post hoc Tukey’s honest significant difference test was used for the statistical analyses (a=0.05). Crowns with reduced cusp inclination exhibited significantly higher fracture load (p<0.01) than crowns with standard cusp inclination. Cemented crowns showed significantly higher fracture load (p<0.01) than screw-retained crowns. The interaction among these factors was not significant (p>0.05) for the fracture load. The sealing of SAH did not influence the fracture load of screw-retained crowns (p>0.05). In conclusion, fracture load of implant-supported metal-ceramic crowns was influenced by retention and cusp inclination, and there was no influence of the sealing of SAH.
id FUNORP-1_bfc84a055670a016ae64408284b3f084
oai_identifier_str oai:scielo:S0103-64402017000100092
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Influence of Cusp Inclination and Type of Retention on Fracture Load of Implant-Supported Crownsdental prosthesisimplant-supported crownsmaterial resistance.Abstract There are few informations about the influence of cusp inclination on the fracture strength of implant-supported crowns. The study aimed to evaluate the influence of cusp inclination and retention type on fracture load in implant-supported metal-ceramic single crowns. Sixty crowns were made, classified as cemented and screw-retained with screw access hole (SAH) sealed or not. Standard (33°) and reduced (20°) cusp inclinations were tested for each group (n=10). To support crowns of a mandibular second molar, analogs of external hexagon implants 5.0 were used. The fracture load was measured in a universal testing machine EMIC DL2000 (10 kN load cell; 0.5 mm/min). Two-way ANOVA (retention and cusp inclination) followed by post hoc Tukey’s honest significant difference test was used for the statistical analyses (a=0.05). Crowns with reduced cusp inclination exhibited significantly higher fracture load (p<0.01) than crowns with standard cusp inclination. Cemented crowns showed significantly higher fracture load (p<0.01) than screw-retained crowns. The interaction among these factors was not significant (p>0.05) for the fracture load. The sealing of SAH did not influence the fracture load of screw-retained crowns (p>0.05). In conclusion, fracture load of implant-supported metal-ceramic crowns was influenced by retention and cusp inclination, and there was no influence of the sealing of SAH.Fundação Odontológica de Ribeirão Preto2017-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402017000100092Brazilian Dental Journal v.28 n.1 2017reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440201701342info:eu-repo/semantics/openAccessRocha,Cibele Oliveira de MeloLonghini,DiogoPereira,Rodrigo de PaulaArioli Filho,João Neudenireng2017-03-07T00:00:00Zoai:scielo:S0103-64402017000100092Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2017-03-07T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Influence of Cusp Inclination and Type of Retention on Fracture Load of Implant-Supported Crowns
title Influence of Cusp Inclination and Type of Retention on Fracture Load of Implant-Supported Crowns
spellingShingle Influence of Cusp Inclination and Type of Retention on Fracture Load of Implant-Supported Crowns
Rocha,Cibele Oliveira de Melo
dental prosthesis
implant-supported crowns
material resistance.
title_short Influence of Cusp Inclination and Type of Retention on Fracture Load of Implant-Supported Crowns
title_full Influence of Cusp Inclination and Type of Retention on Fracture Load of Implant-Supported Crowns
title_fullStr Influence of Cusp Inclination and Type of Retention on Fracture Load of Implant-Supported Crowns
title_full_unstemmed Influence of Cusp Inclination and Type of Retention on Fracture Load of Implant-Supported Crowns
title_sort Influence of Cusp Inclination and Type of Retention on Fracture Load of Implant-Supported Crowns
author Rocha,Cibele Oliveira de Melo
author_facet Rocha,Cibele Oliveira de Melo
Longhini,Diogo
Pereira,Rodrigo de Paula
Arioli Filho,João Neudenir
author_role author
author2 Longhini,Diogo
Pereira,Rodrigo de Paula
Arioli Filho,João Neudenir
author2_role author
author
author
dc.contributor.author.fl_str_mv Rocha,Cibele Oliveira de Melo
Longhini,Diogo
Pereira,Rodrigo de Paula
Arioli Filho,João Neudenir
dc.subject.por.fl_str_mv dental prosthesis
implant-supported crowns
material resistance.
topic dental prosthesis
implant-supported crowns
material resistance.
description Abstract There are few informations about the influence of cusp inclination on the fracture strength of implant-supported crowns. The study aimed to evaluate the influence of cusp inclination and retention type on fracture load in implant-supported metal-ceramic single crowns. Sixty crowns were made, classified as cemented and screw-retained with screw access hole (SAH) sealed or not. Standard (33°) and reduced (20°) cusp inclinations were tested for each group (n=10). To support crowns of a mandibular second molar, analogs of external hexagon implants 5.0 were used. The fracture load was measured in a universal testing machine EMIC DL2000 (10 kN load cell; 0.5 mm/min). Two-way ANOVA (retention and cusp inclination) followed by post hoc Tukey’s honest significant difference test was used for the statistical analyses (a=0.05). Crowns with reduced cusp inclination exhibited significantly higher fracture load (p<0.01) than crowns with standard cusp inclination. Cemented crowns showed significantly higher fracture load (p<0.01) than screw-retained crowns. The interaction among these factors was not significant (p>0.05) for the fracture load. The sealing of SAH did not influence the fracture load of screw-retained crowns (p>0.05). In conclusion, fracture load of implant-supported metal-ceramic crowns was influenced by retention and cusp inclination, and there was no influence of the sealing of SAH.
publishDate 2017
dc.date.none.fl_str_mv 2017-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402017000100092
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402017000100092
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0103-6440201701342
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.28 n.1 2017
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204094469242880