Relation between implant/abutment vertical misfit and torque loss of abutment screws

Detalhes bibliográficos
Autor(a) principal: Barbosa,Gustavo Augusto Seabra
Data de Publicação: 2008
Outros Autores: Bernardes,Sérgio Rocha, Neves,Flávio Domingues das, Fernandes Neto,Alfredo Júlio, Mattos,Maria da Glória Chiarello de, Ribeiro,Ricardo Faria
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402008000400013
Resumo: This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit observed per abutment was used. The torque required to loose the screw was evaluated using a digital torque meter. The torque loss values, measured by the torque meter, were assumed as percentage of initial torque (100%) given to abutment screws. Pearson's correlation (α=0.05) between the misfit values (29.08 ± 8.78 µm) and the percentage of detorque (50.71 ± 11.37%) showed no statistically significant correlation (p=0.295). Within the limitations of this study, it may be concluded that great vertical misfits dot not necessarily implies in higher detorque values.
id FUNORP-1_e9857a0e4c7412d49ce5e897bfecf3f7
oai_identifier_str oai:scielo:S0103-64402008000400013
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Relation between implant/abutment vertical misfit and torque loss of abutment screwsdental prosthesis implant-supportedprosthesis fittingtorqueThis study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit observed per abutment was used. The torque required to loose the screw was evaluated using a digital torque meter. The torque loss values, measured by the torque meter, were assumed as percentage of initial torque (100%) given to abutment screws. Pearson's correlation (α=0.05) between the misfit values (29.08 ± 8.78 µm) and the percentage of detorque (50.71 ± 11.37%) showed no statistically significant correlation (p=0.295). Within the limitations of this study, it may be concluded that great vertical misfits dot not necessarily implies in higher detorque values.Fundação Odontológica de Ribeirão Preto2008-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402008000400013Brazilian Dental Journal v.19 n.4 2008reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402008000400013info:eu-repo/semantics/openAccessBarbosa,Gustavo Augusto SeabraBernardes,Sérgio RochaNeves,Flávio Domingues dasFernandes Neto,Alfredo JúlioMattos,Maria da Glória Chiarello deRibeiro,Ricardo Fariaeng2009-01-26T00:00:00Zoai:scielo:S0103-64402008000400013Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2009-01-26T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Relation between implant/abutment vertical misfit and torque loss of abutment screws
title Relation between implant/abutment vertical misfit and torque loss of abutment screws
spellingShingle Relation between implant/abutment vertical misfit and torque loss of abutment screws
Barbosa,Gustavo Augusto Seabra
dental prosthesis implant-supported
prosthesis fitting
torque
title_short Relation between implant/abutment vertical misfit and torque loss of abutment screws
title_full Relation between implant/abutment vertical misfit and torque loss of abutment screws
title_fullStr Relation between implant/abutment vertical misfit and torque loss of abutment screws
title_full_unstemmed Relation between implant/abutment vertical misfit and torque loss of abutment screws
title_sort Relation between implant/abutment vertical misfit and torque loss of abutment screws
author Barbosa,Gustavo Augusto Seabra
author_facet Barbosa,Gustavo Augusto Seabra
Bernardes,Sérgio Rocha
Neves,Flávio Domingues das
Fernandes Neto,Alfredo Júlio
Mattos,Maria da Glória Chiarello de
Ribeiro,Ricardo Faria
author_role author
author2 Bernardes,Sérgio Rocha
Neves,Flávio Domingues das
Fernandes Neto,Alfredo Júlio
Mattos,Maria da Glória Chiarello de
Ribeiro,Ricardo Faria
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Barbosa,Gustavo Augusto Seabra
Bernardes,Sérgio Rocha
Neves,Flávio Domingues das
Fernandes Neto,Alfredo Júlio
Mattos,Maria da Glória Chiarello de
Ribeiro,Ricardo Faria
dc.subject.por.fl_str_mv dental prosthesis implant-supported
prosthesis fitting
torque
topic dental prosthesis implant-supported
prosthesis fitting
torque
description This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit observed per abutment was used. The torque required to loose the screw was evaluated using a digital torque meter. The torque loss values, measured by the torque meter, were assumed as percentage of initial torque (100%) given to abutment screws. Pearson's correlation (α=0.05) between the misfit values (29.08 ± 8.78 µm) and the percentage of detorque (50.71 ± 11.37%) showed no statistically significant correlation (p=0.295). Within the limitations of this study, it may be concluded that great vertical misfits dot not necessarily implies in higher detorque values.
publishDate 2008
dc.date.none.fl_str_mv 2008-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402008000400013
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402008000400013
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402008000400013
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.19 n.4 2008
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204090917715968