Effect of plasma welding parameters on the flexural strength of ti-6al-4v alloy
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Dental Journal |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402012000600010 |
Resumo: | The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the control group were not sectioned or subjected to welding. Groups PL10, PL12, and PL14 contained titanium beams sectioned and welded at current 3 A for 10, 12 or 14 ms, respectively. Group NCB consisted of NiCr alloy beams welded using conventional torch brazing. After, the beams were subjected to a three-point bending test and the values obtained were analyzed to assess the flexural strength (MPa). Statistical analysis was carried out by one-way ANOVA and Tukey's HSD test at 0.05 confidence level. Significant difference was verified among the evaluated groups (p<0.001), with higher flexural strength for the control group (p<0.05). No significant differences was observed among the plasma welded groups (p>0.05). The NCB group showed the lowest flexural strength, although it was statistically similar to the PL 14 group (p>0.05). The weld depth penetration was not significantly different among the plasma welded groups (p=0.05). Three representative specimens were randomly selected to be evaluated under scanning electron microcopy. The composition of the welded regions was analyzed by energy dispersive X-ray spectroscopy. This study provides an initial set of parameters supporting the use of plasma welding during fabrication of titanium alloy dental frameworks. |
id |
FUNORP-1_f40312ac22393c4748d412e550c34332 |
---|---|
oai_identifier_str |
oai:scielo:S0103-64402012000600010 |
network_acronym_str |
FUNORP-1 |
network_name_str |
Brazilian Dental Journal |
repository_id_str |
|
spelling |
Effect of plasma welding parameters on the flexural strength of ti-6al-4v alloyenergy dispersive spectroscopyflexural strengthplasma arc weldingscanning electron microscopytitanium alloyThe aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the control group were not sectioned or subjected to welding. Groups PL10, PL12, and PL14 contained titanium beams sectioned and welded at current 3 A for 10, 12 or 14 ms, respectively. Group NCB consisted of NiCr alloy beams welded using conventional torch brazing. After, the beams were subjected to a three-point bending test and the values obtained were analyzed to assess the flexural strength (MPa). Statistical analysis was carried out by one-way ANOVA and Tukey's HSD test at 0.05 confidence level. Significant difference was verified among the evaluated groups (p<0.001), with higher flexural strength for the control group (p<0.05). No significant differences was observed among the plasma welded groups (p>0.05). The NCB group showed the lowest flexural strength, although it was statistically similar to the PL 14 group (p>0.05). The weld depth penetration was not significantly different among the plasma welded groups (p=0.05). Three representative specimens were randomly selected to be evaluated under scanning electron microcopy. The composition of the welded regions was analyzed by energy dispersive X-ray spectroscopy. This study provides an initial set of parameters supporting the use of plasma welding during fabrication of titanium alloy dental frameworks.Fundação Odontológica de Ribeirão Preto2012-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402012000600010Brazilian Dental Journal v.23 n.6 2012reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402012000600010info:eu-repo/semantics/openAccessSilva,João Paulo Lyra eFernandes Neto,Alfredo JúlioRaposo,Luís Henrique AraújoNovais,Veridiana ResendeAraujo,Cleudmar Amaral deCavalcante,Luisa de Andrade LimaSimamoto Júnior,Paulo Cezareng2013-01-18T00:00:00Zoai:scielo:S0103-64402012000600010Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2013-01-18T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false |
dc.title.none.fl_str_mv |
Effect of plasma welding parameters on the flexural strength of ti-6al-4v alloy |
title |
Effect of plasma welding parameters on the flexural strength of ti-6al-4v alloy |
spellingShingle |
Effect of plasma welding parameters on the flexural strength of ti-6al-4v alloy Silva,João Paulo Lyra e energy dispersive spectroscopy flexural strength plasma arc welding scanning electron microscopy titanium alloy |
title_short |
Effect of plasma welding parameters on the flexural strength of ti-6al-4v alloy |
title_full |
Effect of plasma welding parameters on the flexural strength of ti-6al-4v alloy |
title_fullStr |
Effect of plasma welding parameters on the flexural strength of ti-6al-4v alloy |
title_full_unstemmed |
Effect of plasma welding parameters on the flexural strength of ti-6al-4v alloy |
title_sort |
Effect of plasma welding parameters on the flexural strength of ti-6al-4v alloy |
author |
Silva,João Paulo Lyra e |
author_facet |
Silva,João Paulo Lyra e Fernandes Neto,Alfredo Júlio Raposo,Luís Henrique Araújo Novais,Veridiana Resende Araujo,Cleudmar Amaral de Cavalcante,Luisa de Andrade Lima Simamoto Júnior,Paulo Cezar |
author_role |
author |
author2 |
Fernandes Neto,Alfredo Júlio Raposo,Luís Henrique Araújo Novais,Veridiana Resende Araujo,Cleudmar Amaral de Cavalcante,Luisa de Andrade Lima Simamoto Júnior,Paulo Cezar |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Silva,João Paulo Lyra e Fernandes Neto,Alfredo Júlio Raposo,Luís Henrique Araújo Novais,Veridiana Resende Araujo,Cleudmar Amaral de Cavalcante,Luisa de Andrade Lima Simamoto Júnior,Paulo Cezar |
dc.subject.por.fl_str_mv |
energy dispersive spectroscopy flexural strength plasma arc welding scanning electron microscopy titanium alloy |
topic |
energy dispersive spectroscopy flexural strength plasma arc welding scanning electron microscopy titanium alloy |
description |
The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the control group were not sectioned or subjected to welding. Groups PL10, PL12, and PL14 contained titanium beams sectioned and welded at current 3 A for 10, 12 or 14 ms, respectively. Group NCB consisted of NiCr alloy beams welded using conventional torch brazing. After, the beams were subjected to a three-point bending test and the values obtained were analyzed to assess the flexural strength (MPa). Statistical analysis was carried out by one-way ANOVA and Tukey's HSD test at 0.05 confidence level. Significant difference was verified among the evaluated groups (p<0.001), with higher flexural strength for the control group (p<0.05). No significant differences was observed among the plasma welded groups (p>0.05). The NCB group showed the lowest flexural strength, although it was statistically similar to the PL 14 group (p>0.05). The weld depth penetration was not significantly different among the plasma welded groups (p=0.05). Three representative specimens were randomly selected to be evaluated under scanning electron microcopy. The composition of the welded regions was analyzed by energy dispersive X-ray spectroscopy. This study provides an initial set of parameters supporting the use of plasma welding during fabrication of titanium alloy dental frameworks. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402012000600010 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402012000600010 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-64402012000600010 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
dc.source.none.fl_str_mv |
Brazilian Dental Journal v.23 n.6 2012 reponame:Brazilian Dental Journal instname:Fundação Odontológica de Ribeirão Preto (FUNORP) instacron:FUNORP |
instname_str |
Fundação Odontológica de Ribeirão Preto (FUNORP) |
instacron_str |
FUNORP |
institution |
FUNORP |
reponame_str |
Brazilian Dental Journal |
collection |
Brazilian Dental Journal |
repository.name.fl_str_mv |
Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP) |
repository.mail.fl_str_mv |
bdj@forp.usp.br||sergio@fosjc.unesp.br |
_version_ |
1754204092294496256 |