Fluoride release profile of a nanofilled resin-modified glass ionomer cement

Detalhes bibliográficos
Autor(a) principal: Paschoal,Marco Aurélio Benini
Data de Publicação: 2011
Outros Autores: Gurgel,Carla Vecchione, Rios,Daniela, Magalhães,Ana Carolina, Buzalaf,Marília Afonso Rabelo, Machado,Maria Aparecida de Andrade Moreira
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000400002
Resumo: The present study aimed to compare the fluoride (F-) release pattern of a nanofilled resin-modified glass ionomer cement (GIC) (Ketac N100 - KN) with available GICs used in dental practice (resin-modified GIC - Vitremer - V; conventional GIC - Ketac Molar - KM) and a nanofilled resin composite (Filtek Supreme - RC). Discs of each material (n=6) were placed into 4 mL of deionized water in sealed polyethylene vials and shaken, for 15 days. F- release (μg F-/cm²) was measured each day using a fluoride-ion specific electrode. Cumulative F- release means were statistically analyzed by linear regression analysis. In order to analyze the differences among materials and the influence of time in the daily F- release, 2-way ANOVA test was performed (α=0.05). The linear fits between the cumulative F- release profiles of RC and KM and time were weak. KN and V presented a strong relationship between cumulative F- release and time. There were significant differences between the daily F- release overtime up to the third day only for GICs materials. The daily F- release means for RC were similar overtime. The results indicate that the F- release profile of the nanofilled resin-modified GIC is comparable to the resin-modified GIC.
id FUNORP-1_ff5db1173a437d5404eac920ab677c74
oai_identifier_str oai:scielo:S0103-64402011000400002
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Fluoride release profile of a nanofilled resin-modified glass ionomer cementglass ionomer cementfluoridein vitroThe present study aimed to compare the fluoride (F-) release pattern of a nanofilled resin-modified glass ionomer cement (GIC) (Ketac N100 - KN) with available GICs used in dental practice (resin-modified GIC - Vitremer - V; conventional GIC - Ketac Molar - KM) and a nanofilled resin composite (Filtek Supreme - RC). Discs of each material (n=6) were placed into 4 mL of deionized water in sealed polyethylene vials and shaken, for 15 days. F- release (μg F-/cm²) was measured each day using a fluoride-ion specific electrode. Cumulative F- release means were statistically analyzed by linear regression analysis. In order to analyze the differences among materials and the influence of time in the daily F- release, 2-way ANOVA test was performed (α=0.05). The linear fits between the cumulative F- release profiles of RC and KM and time were weak. KN and V presented a strong relationship between cumulative F- release and time. There were significant differences between the daily F- release overtime up to the third day only for GICs materials. The daily F- release means for RC were similar overtime. The results indicate that the F- release profile of the nanofilled resin-modified GIC is comparable to the resin-modified GIC.Fundação Odontológica de Ribeirão Preto2011-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000400002Brazilian Dental Journal v.22 n.4 2011reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402011000400002info:eu-repo/semantics/openAccessPaschoal,Marco Aurélio BeniniGurgel,Carla VecchioneRios,DanielaMagalhães,Ana CarolinaBuzalaf,Marília Afonso RabeloMachado,Maria Aparecida de Andrade Moreiraeng2011-08-12T00:00:00Zoai:scielo:S0103-64402011000400002Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2011-08-12T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Fluoride release profile of a nanofilled resin-modified glass ionomer cement
title Fluoride release profile of a nanofilled resin-modified glass ionomer cement
spellingShingle Fluoride release profile of a nanofilled resin-modified glass ionomer cement
Paschoal,Marco Aurélio Benini
glass ionomer cement
fluoride
in vitro
title_short Fluoride release profile of a nanofilled resin-modified glass ionomer cement
title_full Fluoride release profile of a nanofilled resin-modified glass ionomer cement
title_fullStr Fluoride release profile of a nanofilled resin-modified glass ionomer cement
title_full_unstemmed Fluoride release profile of a nanofilled resin-modified glass ionomer cement
title_sort Fluoride release profile of a nanofilled resin-modified glass ionomer cement
author Paschoal,Marco Aurélio Benini
author_facet Paschoal,Marco Aurélio Benini
Gurgel,Carla Vecchione
Rios,Daniela
Magalhães,Ana Carolina
Buzalaf,Marília Afonso Rabelo
Machado,Maria Aparecida de Andrade Moreira
author_role author
author2 Gurgel,Carla Vecchione
Rios,Daniela
Magalhães,Ana Carolina
Buzalaf,Marília Afonso Rabelo
Machado,Maria Aparecida de Andrade Moreira
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Paschoal,Marco Aurélio Benini
Gurgel,Carla Vecchione
Rios,Daniela
Magalhães,Ana Carolina
Buzalaf,Marília Afonso Rabelo
Machado,Maria Aparecida de Andrade Moreira
dc.subject.por.fl_str_mv glass ionomer cement
fluoride
in vitro
topic glass ionomer cement
fluoride
in vitro
description The present study aimed to compare the fluoride (F-) release pattern of a nanofilled resin-modified glass ionomer cement (GIC) (Ketac N100 - KN) with available GICs used in dental practice (resin-modified GIC - Vitremer - V; conventional GIC - Ketac Molar - KM) and a nanofilled resin composite (Filtek Supreme - RC). Discs of each material (n=6) were placed into 4 mL of deionized water in sealed polyethylene vials and shaken, for 15 days. F- release (μg F-/cm²) was measured each day using a fluoride-ion specific electrode. Cumulative F- release means were statistically analyzed by linear regression analysis. In order to analyze the differences among materials and the influence of time in the daily F- release, 2-way ANOVA test was performed (α=0.05). The linear fits between the cumulative F- release profiles of RC and KM and time were weak. KN and V presented a strong relationship between cumulative F- release and time. There were significant differences between the daily F- release overtime up to the third day only for GICs materials. The daily F- release means for RC were similar overtime. The results indicate that the F- release profile of the nanofilled resin-modified GIC is comparable to the resin-modified GIC.
publishDate 2011
dc.date.none.fl_str_mv 2011-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000400002
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000400002
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402011000400002
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.22 n.4 2011
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204091790131200