Model for the IEEE 34 radial distribution test feeder with no load condition
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Vetor (Online) |
Texto Completo: | https://periodicos.furg.br/vetor/article/view/1681 |
Resumo: | This work proposes a Simulink/MATLAB model for the IEEE 34 radial distribution test feeder with no load condition. It is useful to test and compare computer programs for analysis of radial distribution feeders. The results show that, although unstable, the voltage levels for both, the three phase and single phase line sections, are within the expected values, considering the lines resistance and reactance, and also no regulation and no load conditions. The model created in this work is intended for systems studies. |
id |
FURG-7_7cafd231c69345a52911a99c99d4780d |
---|---|
oai_identifier_str |
oai:periodicos.furg.br:article/1681 |
network_acronym_str |
FURG-7 |
network_name_str |
Vetor (Online) |
repository_id_str |
|
spelling |
Model for the IEEE 34 radial distribution test feeder with no load conditionModelagem a vazio do sistema teste de distribuição de 34 nós IEEE pelo software Simulink em ambiente MatLab™Sistema de distribuição de 34 nós da IEEEMatLab™Simulação.This work proposes a Simulink/MATLAB model for the IEEE 34 radial distribution test feeder with no load condition. It is useful to test and compare computer programs for analysis of radial distribution feeders. The results show that, although unstable, the voltage levels for both, the three phase and single phase line sections, are within the expected values, considering the lines resistance and reactance, and also no regulation and no load conditions. The model created in this work is intended for systems studies.Este trabalho propõe um modelo em simulink/MatLab para o sistema teste de distribuição de 34 nós IEEE operando a vazio. É usado para testar e comparar os programas computacionais existentes para análise de alimentadores de distribuição radial. Os resultados mostram que, apesar de instáveis, os níveis de tensão para ambos, as secções trifásicas e monofásicas, estão dentro dos valores esperados, considerando a resistência e reatância das linhas, e também a regulação não e não condições de carga. O modelo criado neste trabalho destina-se a estudos de sistemas.Universidade Federal do Rio Grande2010-12-06info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://periodicos.furg.br/vetor/article/view/1681VETOR - Journal of Exact Sciences and Engineering; Vol. 18 No. 1 (2008); 46-56VETOR - Revista de Ciências Exatas e Engenharias; v. 18 n. 1 (2008); 46-562358-34520102-7352reponame:Vetor (Online)instname:Universidade Federal do Rio Grande (FURG)instacron:FURGporhttps://periodicos.furg.br/vetor/article/view/1681/833Copyright (c) 2014 VETOR - Revista de Ciências Exatas e Engenhariasinfo:eu-repo/semantics/openAccessVieira, Tallita LisboaSilva, Valceres V. R.2023-03-22T15:42:40Zoai:periodicos.furg.br:article/1681Revistahttps://periodicos.furg.br/vetorPUBhttps://periodicos.furg.br/vetor/oaigmplatt@furg.br2358-34520102-7352opendoar:2023-03-22T15:42:40Vetor (Online) - Universidade Federal do Rio Grande (FURG)false |
dc.title.none.fl_str_mv |
Model for the IEEE 34 radial distribution test feeder with no load condition Modelagem a vazio do sistema teste de distribuição de 34 nós IEEE pelo software Simulink em ambiente MatLab™ |
title |
Model for the IEEE 34 radial distribution test feeder with no load condition |
spellingShingle |
Model for the IEEE 34 radial distribution test feeder with no load condition Vieira, Tallita Lisboa Sistema de distribuição de 34 nós da IEEE MatLab™ Simulação. |
title_short |
Model for the IEEE 34 radial distribution test feeder with no load condition |
title_full |
Model for the IEEE 34 radial distribution test feeder with no load condition |
title_fullStr |
Model for the IEEE 34 radial distribution test feeder with no load condition |
title_full_unstemmed |
Model for the IEEE 34 radial distribution test feeder with no load condition |
title_sort |
Model for the IEEE 34 radial distribution test feeder with no load condition |
author |
Vieira, Tallita Lisboa |
author_facet |
Vieira, Tallita Lisboa Silva, Valceres V. R. |
author_role |
author |
author2 |
Silva, Valceres V. R. |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Vieira, Tallita Lisboa Silva, Valceres V. R. |
dc.subject.por.fl_str_mv |
Sistema de distribuição de 34 nós da IEEE MatLab™ Simulação. |
topic |
Sistema de distribuição de 34 nós da IEEE MatLab™ Simulação. |
description |
This work proposes a Simulink/MATLAB model for the IEEE 34 radial distribution test feeder with no load condition. It is useful to test and compare computer programs for analysis of radial distribution feeders. The results show that, although unstable, the voltage levels for both, the three phase and single phase line sections, are within the expected values, considering the lines resistance and reactance, and also no regulation and no load conditions. The model created in this work is intended for systems studies. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-12-06 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.furg.br/vetor/article/view/1681 |
url |
https://periodicos.furg.br/vetor/article/view/1681 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://periodicos.furg.br/vetor/article/view/1681/833 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2014 VETOR - Revista de Ciências Exatas e Engenharias info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2014 VETOR - Revista de Ciências Exatas e Engenharias |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal do Rio Grande |
publisher.none.fl_str_mv |
Universidade Federal do Rio Grande |
dc.source.none.fl_str_mv |
VETOR - Journal of Exact Sciences and Engineering; Vol. 18 No. 1 (2008); 46-56 VETOR - Revista de Ciências Exatas e Engenharias; v. 18 n. 1 (2008); 46-56 2358-3452 0102-7352 reponame:Vetor (Online) instname:Universidade Federal do Rio Grande (FURG) instacron:FURG |
instname_str |
Universidade Federal do Rio Grande (FURG) |
instacron_str |
FURG |
institution |
FURG |
reponame_str |
Vetor (Online) |
collection |
Vetor (Online) |
repository.name.fl_str_mv |
Vetor (Online) - Universidade Federal do Rio Grande (FURG) |
repository.mail.fl_str_mv |
gmplatt@furg.br |
_version_ |
1797041761178091520 |