Numerical study of the influence of geometric parameters on the avaliable power in a solar chimney

Detalhes bibliográficos
Autor(a) principal: Vieira, Rodrigo Spotorno
Data de Publicação: 2015
Outros Autores: Garcia, Claudio, Acunha Junior, Ivoni Carlos, Souza, Jeferson Avila, Rocha, Luis Alberto Oliveira, Isoldi, Liércio André, Santos, Elizaldo Domingues dos
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da FURG (RI FURG)
Texto Completo: http://repositorio.furg.br/handle/1/5149
Resumo: In the presented work, it is made a numerical study about the main physical principle of a solar chimney (SCPP – Solar Chimney Power Plant) and the influence of some geometric parameters on the available power in the SCPP. The main objectives are to test the applicability of the studied numerical model in future studies of SCPP geometric optimization and to test the action of the collector inlet height (H1) and the chimney outlet diameter (D2) on the available power of the device. For that it is considered an incompressible, turbulent, steady flow with mixed convective heat transfer in a two-dimensional and axisymmetric domain, similar to the one found in a solar chimney. The conservation equations of mass, momentum and energy are numerically solved using the finite volume method, more specifically with the FLUENT software. The classical turbulence modeling (RANS) was used for the turbulence approach with standard model k – ε. The other geometric parameters: collector radius (R) and the inlet and outlet of the turbine section, R1 and R2, are also constant. The verification results indicated a good agreement with those presented in the literature, even using a simplified domain. It was also observed that the H1 parameter is almost insensitive in the solar chimney performance, whereas the D2 variable presented great influence in the available power. The best performance was attained for an intermediate value of D2, D2 = 0.44 m. For this value, the available power was almost 72% and 19% higher from those obtained in the inferior and superior extremes of the studied D2 variable, D2 = 0.22 m and 0.88 m, respectively. It was also observed that there is a very good possibility of optimization of the chimney geometry in future studies.
id FURG_659d4f91ab8c683888d9e6c8b4603a45
oai_identifier_str oai:repositorio.furg.br:1/5149
network_acronym_str FURG
network_name_str Repositório Institucional da FURG (RI FURG)
repository_id_str
spelling Numerical study of the influence of geometric parameters on the avaliable power in a solar chimneySolar chimneyNumerical studyAvailable PowerGeometric parametersIn the presented work, it is made a numerical study about the main physical principle of a solar chimney (SCPP – Solar Chimney Power Plant) and the influence of some geometric parameters on the available power in the SCPP. The main objectives are to test the applicability of the studied numerical model in future studies of SCPP geometric optimization and to test the action of the collector inlet height (H1) and the chimney outlet diameter (D2) on the available power of the device. For that it is considered an incompressible, turbulent, steady flow with mixed convective heat transfer in a two-dimensional and axisymmetric domain, similar to the one found in a solar chimney. The conservation equations of mass, momentum and energy are numerically solved using the finite volume method, more specifically with the FLUENT software. The classical turbulence modeling (RANS) was used for the turbulence approach with standard model k – ε. The other geometric parameters: collector radius (R) and the inlet and outlet of the turbine section, R1 and R2, are also constant. The verification results indicated a good agreement with those presented in the literature, even using a simplified domain. It was also observed that the H1 parameter is almost insensitive in the solar chimney performance, whereas the D2 variable presented great influence in the available power. The best performance was attained for an intermediate value of D2, D2 = 0.44 m. For this value, the available power was almost 72% and 19% higher from those obtained in the inferior and superior extremes of the studied D2 variable, D2 = 0.22 m and 0.88 m, respectively. It was also observed that there is a very good possibility of optimization of the chimney geometry in future studies.2015-07-20T23:03:55Z2015-07-20T23:03:55Z2015info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfVIEIRA, R. S. et al. Numerical study of the influence of geometric parameters on the avaliable power in a solar chimney. Engenharia Térmica, v. 14, n. 1, p. 103-109, 2015. Disponível em: <http://demec.ufpr.br/reterm/artigos/350-2015.pdf>. Acesso em: 18 jul. 2015.1676-1790http://repositorio.furg.br/handle/1/5149engVieira, Rodrigo SpotornoGarcia, ClaudioAcunha Junior, Ivoni CarlosSouza, Jeferson AvilaRocha, Luis Alberto OliveiraIsoldi, Liércio AndréSantos, Elizaldo Domingues dosinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da FURG (RI FURG)instname:Universidade Federal do Rio Grande (FURG)instacron:FURG2017-05-31T20:09:25Zoai:repositorio.furg.br:1/5149Repositório InstitucionalPUBhttps://repositorio.furg.br/oai/request || http://200.19.254.174/oai/requestopendoar:2017-05-31T20:09:25Repositório Institucional da FURG (RI FURG) - Universidade Federal do Rio Grande (FURG)false
dc.title.none.fl_str_mv Numerical study of the influence of geometric parameters on the avaliable power in a solar chimney
title Numerical study of the influence of geometric parameters on the avaliable power in a solar chimney
spellingShingle Numerical study of the influence of geometric parameters on the avaliable power in a solar chimney
Vieira, Rodrigo Spotorno
Solar chimney
Numerical study
Available Power
Geometric parameters
title_short Numerical study of the influence of geometric parameters on the avaliable power in a solar chimney
title_full Numerical study of the influence of geometric parameters on the avaliable power in a solar chimney
title_fullStr Numerical study of the influence of geometric parameters on the avaliable power in a solar chimney
title_full_unstemmed Numerical study of the influence of geometric parameters on the avaliable power in a solar chimney
title_sort Numerical study of the influence of geometric parameters on the avaliable power in a solar chimney
author Vieira, Rodrigo Spotorno
author_facet Vieira, Rodrigo Spotorno
Garcia, Claudio
Acunha Junior, Ivoni Carlos
Souza, Jeferson Avila
Rocha, Luis Alberto Oliveira
Isoldi, Liércio André
Santos, Elizaldo Domingues dos
author_role author
author2 Garcia, Claudio
Acunha Junior, Ivoni Carlos
Souza, Jeferson Avila
Rocha, Luis Alberto Oliveira
Isoldi, Liércio André
Santos, Elizaldo Domingues dos
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Vieira, Rodrigo Spotorno
Garcia, Claudio
Acunha Junior, Ivoni Carlos
Souza, Jeferson Avila
Rocha, Luis Alberto Oliveira
Isoldi, Liércio André
Santos, Elizaldo Domingues dos
dc.subject.por.fl_str_mv Solar chimney
Numerical study
Available Power
Geometric parameters
topic Solar chimney
Numerical study
Available Power
Geometric parameters
description In the presented work, it is made a numerical study about the main physical principle of a solar chimney (SCPP – Solar Chimney Power Plant) and the influence of some geometric parameters on the available power in the SCPP. The main objectives are to test the applicability of the studied numerical model in future studies of SCPP geometric optimization and to test the action of the collector inlet height (H1) and the chimney outlet diameter (D2) on the available power of the device. For that it is considered an incompressible, turbulent, steady flow with mixed convective heat transfer in a two-dimensional and axisymmetric domain, similar to the one found in a solar chimney. The conservation equations of mass, momentum and energy are numerically solved using the finite volume method, more specifically with the FLUENT software. The classical turbulence modeling (RANS) was used for the turbulence approach with standard model k – ε. The other geometric parameters: collector radius (R) and the inlet and outlet of the turbine section, R1 and R2, are also constant. The verification results indicated a good agreement with those presented in the literature, even using a simplified domain. It was also observed that the H1 parameter is almost insensitive in the solar chimney performance, whereas the D2 variable presented great influence in the available power. The best performance was attained for an intermediate value of D2, D2 = 0.44 m. For this value, the available power was almost 72% and 19% higher from those obtained in the inferior and superior extremes of the studied D2 variable, D2 = 0.22 m and 0.88 m, respectively. It was also observed that there is a very good possibility of optimization of the chimney geometry in future studies.
publishDate 2015
dc.date.none.fl_str_mv 2015-07-20T23:03:55Z
2015-07-20T23:03:55Z
2015
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv VIEIRA, R. S. et al. Numerical study of the influence of geometric parameters on the avaliable power in a solar chimney. Engenharia Térmica, v. 14, n. 1, p. 103-109, 2015. Disponível em: <http://demec.ufpr.br/reterm/artigos/350-2015.pdf>. Acesso em: 18 jul. 2015.
1676-1790
http://repositorio.furg.br/handle/1/5149
identifier_str_mv VIEIRA, R. S. et al. Numerical study of the influence of geometric parameters on the avaliable power in a solar chimney. Engenharia Térmica, v. 14, n. 1, p. 103-109, 2015. Disponível em: <http://demec.ufpr.br/reterm/artigos/350-2015.pdf>. Acesso em: 18 jul. 2015.
1676-1790
url http://repositorio.furg.br/handle/1/5149
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da FURG (RI FURG)
instname:Universidade Federal do Rio Grande (FURG)
instacron:FURG
instname_str Universidade Federal do Rio Grande (FURG)
instacron_str FURG
institution FURG
reponame_str Repositório Institucional da FURG (RI FURG)
collection Repositório Institucional da FURG (RI FURG)
repository.name.fl_str_mv Repositório Institucional da FURG (RI FURG) - Universidade Federal do Rio Grande (FURG)
repository.mail.fl_str_mv
_version_ 1807384395794874368