NORMAL VALUES OF ESOPHAGEAL HIGH-RESOLUTION MANOMETRY: A BRAZILIAN MULTICENTER STUDY

Detalhes bibliográficos
Autor(a) principal: DOMINGUES,Gerson Ricardo
Data de Publicação: 2020
Outros Autores: MICHELSOHN,Nelson Henrique, VIEBIG,Ricardo Guilherme, CHINZON,Décio, NASI,Ary, ANDRADE,Carla Granja, LEMME,Eponina Maria, ABRAHÃO JUNIOR,Luiz João, BRAVIM,Mauricio Gustavo, NOBRE-E-SOUZA,Miguel Ângelo, CARVALHO,Nayara Salgado, CARVALHO,Paulo J P C, RODRIGUES,Tomás Navarro, MORAES FILHO,Joaquim Prado P
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos de gastroenterologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032020000200209
Resumo: ABSTRACT BACKGROUND: The high-resolution manometry has been a significant advance in esophageal diagnostics. There are different types of catheter and systems devices to capture esophageal pressures that generate variable data related to Chicago Classification (CC) and consequently influence normal values results. There are not normative data for the 24-channel water-perfused high-resolution manometry system most used in Brazil with healthy volunteers in supine posture. OBJECTIVE: To determine manometric esophageal normative values for a 24-channel water-perfused high-resolution manometry catheter in supine posture using healthy volunteers according to CC 3.0 parameters. METHODS: A total of 92 volunteers with no gastrointestinal symptoms or medications affecting GI motility underwent esophageal high-resolution manometry by standard protocol. Age, gender and manometry parameters analyzed using Alacer software were collected. The median, range, and 5th and 95th percentiles (where applicable) were obtained for all high-resolution manometry metrics. Normal value percentiles were defined as 95th integrated relaxation pressure, 5th-100th distal contractile integral, and 5th distal latency. RESULTS: The mean age was 40.5±13.2 years. Our normative metrics were integrated relaxation pressure <16 mmHg and distal contractile integral (708-4111 mmHg.cm.s) distal latency was <6 s and peristaltic break size (>4 cm). For EGJ-CI the range 5th-95th was 21.7-86.9 mmHg.cm.s. CONCLUSION: This is the first report of normative data for the 24-channel water-perfused system in supine posture. It revealed higher integrated relaxation pressure and distal latency duration which suggest the need to change CC 3.0 cutoffs for this system. It is observed that there is a tendency that DCI >7000 mmHg.cm.s may represent the lower limit of hypercontractility, and when <700 mmHg.cm.s (<5% percentile) interpreted as ineffective esophageal motility or failcontraction. Also compared to Chicago 3.0, higher integrated relaxation pressure and duration of distal latency were found. We emphasize that these data must be confirmed by future studies.
id IBEPEGE-1_0b943d0e9d108093635c8f6519c79b39
oai_identifier_str oai:scielo:S0004-28032020000200209
network_acronym_str IBEPEGE-1
network_name_str Arquivos de gastroenterologia (Online)
repository_id_str
spelling NORMAL VALUES OF ESOPHAGEAL HIGH-RESOLUTION MANOMETRY: A BRAZILIAN MULTICENTER STUDYEsophagusGastrointestinal motilityManometryPeristalsisReference values.ABSTRACT BACKGROUND: The high-resolution manometry has been a significant advance in esophageal diagnostics. There are different types of catheter and systems devices to capture esophageal pressures that generate variable data related to Chicago Classification (CC) and consequently influence normal values results. There are not normative data for the 24-channel water-perfused high-resolution manometry system most used in Brazil with healthy volunteers in supine posture. OBJECTIVE: To determine manometric esophageal normative values for a 24-channel water-perfused high-resolution manometry catheter in supine posture using healthy volunteers according to CC 3.0 parameters. METHODS: A total of 92 volunteers with no gastrointestinal symptoms or medications affecting GI motility underwent esophageal high-resolution manometry by standard protocol. Age, gender and manometry parameters analyzed using Alacer software were collected. The median, range, and 5th and 95th percentiles (where applicable) were obtained for all high-resolution manometry metrics. Normal value percentiles were defined as 95th integrated relaxation pressure, 5th-100th distal contractile integral, and 5th distal latency. RESULTS: The mean age was 40.5±13.2 years. Our normative metrics were integrated relaxation pressure <16 mmHg and distal contractile integral (708-4111 mmHg.cm.s) distal latency was <6 s and peristaltic break size (>4 cm). For EGJ-CI the range 5th-95th was 21.7-86.9 mmHg.cm.s. CONCLUSION: This is the first report of normative data for the 24-channel water-perfused system in supine posture. It revealed higher integrated relaxation pressure and distal latency duration which suggest the need to change CC 3.0 cutoffs for this system. It is observed that there is a tendency that DCI >7000 mmHg.cm.s may represent the lower limit of hypercontractility, and when <700 mmHg.cm.s (<5% percentile) interpreted as ineffective esophageal motility or failcontraction. Also compared to Chicago 3.0, higher integrated relaxation pressure and duration of distal latency were found. We emphasize that these data must be confirmed by future studies.Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia e Outras Especialidades - IBEPEGE. 2020-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032020000200209Arquivos de Gastroenterologia v.57 n.2 2020reponame:Arquivos de gastroenterologia (Online)instname:Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologiainstacron:IBEPEGE10.1590/s0004-2803.202000000-40info:eu-repo/semantics/openAccessDOMINGUES,Gerson RicardoMICHELSOHN,Nelson HenriqueVIEBIG,Ricardo GuilhermeCHINZON,DécioNASI,AryANDRADE,Carla GranjaLEMME,Eponina MariaABRAHÃO JUNIOR,Luiz JoãoBRAVIM,Mauricio GustavoNOBRE-E-SOUZA,Miguel ÂngeloCARVALHO,Nayara SalgadoCARVALHO,Paulo J P CRODRIGUES,Tomás NavarroMORAES FILHO,Joaquim Prado Peng2020-11-10T00:00:00Zoai:scielo:S0004-28032020000200209Revistahttp://www.scielo.br/aghttps://old.scielo.br/oai/scielo-oai.php||secretariaarqgastr@hospitaligesp.com.br1678-42190004-2803opendoar:2020-11-10T00:00Arquivos de gastroenterologia (Online) - Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologiafalse
dc.title.none.fl_str_mv NORMAL VALUES OF ESOPHAGEAL HIGH-RESOLUTION MANOMETRY: A BRAZILIAN MULTICENTER STUDY
title NORMAL VALUES OF ESOPHAGEAL HIGH-RESOLUTION MANOMETRY: A BRAZILIAN MULTICENTER STUDY
spellingShingle NORMAL VALUES OF ESOPHAGEAL HIGH-RESOLUTION MANOMETRY: A BRAZILIAN MULTICENTER STUDY
DOMINGUES,Gerson Ricardo
Esophagus
Gastrointestinal motility
Manometry
Peristalsis
Reference values.
title_short NORMAL VALUES OF ESOPHAGEAL HIGH-RESOLUTION MANOMETRY: A BRAZILIAN MULTICENTER STUDY
title_full NORMAL VALUES OF ESOPHAGEAL HIGH-RESOLUTION MANOMETRY: A BRAZILIAN MULTICENTER STUDY
title_fullStr NORMAL VALUES OF ESOPHAGEAL HIGH-RESOLUTION MANOMETRY: A BRAZILIAN MULTICENTER STUDY
title_full_unstemmed NORMAL VALUES OF ESOPHAGEAL HIGH-RESOLUTION MANOMETRY: A BRAZILIAN MULTICENTER STUDY
title_sort NORMAL VALUES OF ESOPHAGEAL HIGH-RESOLUTION MANOMETRY: A BRAZILIAN MULTICENTER STUDY
author DOMINGUES,Gerson Ricardo
author_facet DOMINGUES,Gerson Ricardo
MICHELSOHN,Nelson Henrique
VIEBIG,Ricardo Guilherme
CHINZON,Décio
NASI,Ary
ANDRADE,Carla Granja
LEMME,Eponina Maria
ABRAHÃO JUNIOR,Luiz João
BRAVIM,Mauricio Gustavo
NOBRE-E-SOUZA,Miguel Ângelo
CARVALHO,Nayara Salgado
CARVALHO,Paulo J P C
RODRIGUES,Tomás Navarro
MORAES FILHO,Joaquim Prado P
author_role author
author2 MICHELSOHN,Nelson Henrique
VIEBIG,Ricardo Guilherme
CHINZON,Décio
NASI,Ary
ANDRADE,Carla Granja
LEMME,Eponina Maria
ABRAHÃO JUNIOR,Luiz João
BRAVIM,Mauricio Gustavo
NOBRE-E-SOUZA,Miguel Ângelo
CARVALHO,Nayara Salgado
CARVALHO,Paulo J P C
RODRIGUES,Tomás Navarro
MORAES FILHO,Joaquim Prado P
author2_role author
author
author
author
author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv DOMINGUES,Gerson Ricardo
MICHELSOHN,Nelson Henrique
VIEBIG,Ricardo Guilherme
CHINZON,Décio
NASI,Ary
ANDRADE,Carla Granja
LEMME,Eponina Maria
ABRAHÃO JUNIOR,Luiz João
BRAVIM,Mauricio Gustavo
NOBRE-E-SOUZA,Miguel Ângelo
CARVALHO,Nayara Salgado
CARVALHO,Paulo J P C
RODRIGUES,Tomás Navarro
MORAES FILHO,Joaquim Prado P
dc.subject.por.fl_str_mv Esophagus
Gastrointestinal motility
Manometry
Peristalsis
Reference values.
topic Esophagus
Gastrointestinal motility
Manometry
Peristalsis
Reference values.
description ABSTRACT BACKGROUND: The high-resolution manometry has been a significant advance in esophageal diagnostics. There are different types of catheter and systems devices to capture esophageal pressures that generate variable data related to Chicago Classification (CC) and consequently influence normal values results. There are not normative data for the 24-channel water-perfused high-resolution manometry system most used in Brazil with healthy volunteers in supine posture. OBJECTIVE: To determine manometric esophageal normative values for a 24-channel water-perfused high-resolution manometry catheter in supine posture using healthy volunteers according to CC 3.0 parameters. METHODS: A total of 92 volunteers with no gastrointestinal symptoms or medications affecting GI motility underwent esophageal high-resolution manometry by standard protocol. Age, gender and manometry parameters analyzed using Alacer software were collected. The median, range, and 5th and 95th percentiles (where applicable) were obtained for all high-resolution manometry metrics. Normal value percentiles were defined as 95th integrated relaxation pressure, 5th-100th distal contractile integral, and 5th distal latency. RESULTS: The mean age was 40.5±13.2 years. Our normative metrics were integrated relaxation pressure <16 mmHg and distal contractile integral (708-4111 mmHg.cm.s) distal latency was <6 s and peristaltic break size (>4 cm). For EGJ-CI the range 5th-95th was 21.7-86.9 mmHg.cm.s. CONCLUSION: This is the first report of normative data for the 24-channel water-perfused system in supine posture. It revealed higher integrated relaxation pressure and distal latency duration which suggest the need to change CC 3.0 cutoffs for this system. It is observed that there is a tendency that DCI >7000 mmHg.cm.s may represent the lower limit of hypercontractility, and when <700 mmHg.cm.s (<5% percentile) interpreted as ineffective esophageal motility or failcontraction. Also compared to Chicago 3.0, higher integrated relaxation pressure and duration of distal latency were found. We emphasize that these data must be confirmed by future studies.
publishDate 2020
dc.date.none.fl_str_mv 2020-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032020000200209
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032020000200209
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s0004-2803.202000000-40
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia e Outras Especialidades - IBEPEGE.
publisher.none.fl_str_mv Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia e Outras Especialidades - IBEPEGE.
dc.source.none.fl_str_mv Arquivos de Gastroenterologia v.57 n.2 2020
reponame:Arquivos de gastroenterologia (Online)
instname:Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia
instacron:IBEPEGE
instname_str Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia
instacron_str IBEPEGE
institution IBEPEGE
reponame_str Arquivos de gastroenterologia (Online)
collection Arquivos de gastroenterologia (Online)
repository.name.fl_str_mv Arquivos de gastroenterologia (Online) - Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia
repository.mail.fl_str_mv ||secretariaarqgastr@hospitaligesp.com.br
_version_ 1754193350222675968