Endoscope reprocessing using glutaraldehyde in endoscopy services of Goiânia, Brazil
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos de gastroenterologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032010000300002 |
Resumo: | CONTEXT: The endoscopic procedure safety depends on the use of an adequately reprocessed device which quality is related to each of its operational steps. OBJECTIVE: To characterize the reprocessing of endoscopes using glutaraldehyde in endoscopy services METHODS: Study was conducted by observing the reprocessing of 60 endoscopes from 20 medical practices of the municipality of Goiânia, GO, central area of Brazil. RESULTS: This study showed failure in all reprocessing steps. The pre-washing was performed in 24 (40.0%) of the endoscope. In the cleaning steps, was identify the improper use of enzymatic detergent, and in 27 (45.0%) cases, the brushing of internal channels was not performed. All 60 endoscopes were submitted to this disinfectant. However, for 33 (55.0%) of the cases the internal channels was not filled. The total immersion of endoscope in the glutaraldehyde was not performed in 39 (65.0%) cases. The recommended minimum total immersion time for exposure to 2% glutaraldehyde solution was followed only for 12 (20.0%) endoscopes. There was no filter for water treatment used in the rinse of most endoscopes 54 (90.0%) and to dry the internal channels only 6 (10.0%) of them used compressed air. Adequate storing conditions were identified. CONCLUSION: Considering the particularities of the endoscope and its reprocessing, it is imperative to establish protocols to ensure the quality of the disinfection and the prevention of cross-contamination. |
id |
IBEPEGE-1_85c79cf963c1c97ce3aef171649b7ee3 |
---|---|
oai_identifier_str |
oai:scielo:S0004-28032010000300002 |
network_acronym_str |
IBEPEGE-1 |
network_name_str |
Arquivos de gastroenterologia (Online) |
repository_id_str |
|
spelling |
Endoscope reprocessing using glutaraldehyde in endoscopy services of Goiânia, BrazilEndoscopes, gastrointestinalDisinfectionEquipment contaminationGlutaralCONTEXT: The endoscopic procedure safety depends on the use of an adequately reprocessed device which quality is related to each of its operational steps. OBJECTIVE: To characterize the reprocessing of endoscopes using glutaraldehyde in endoscopy services METHODS: Study was conducted by observing the reprocessing of 60 endoscopes from 20 medical practices of the municipality of Goiânia, GO, central area of Brazil. RESULTS: This study showed failure in all reprocessing steps. The pre-washing was performed in 24 (40.0%) of the endoscope. In the cleaning steps, was identify the improper use of enzymatic detergent, and in 27 (45.0%) cases, the brushing of internal channels was not performed. All 60 endoscopes were submitted to this disinfectant. However, for 33 (55.0%) of the cases the internal channels was not filled. The total immersion of endoscope in the glutaraldehyde was not performed in 39 (65.0%) cases. The recommended minimum total immersion time for exposure to 2% glutaraldehyde solution was followed only for 12 (20.0%) endoscopes. There was no filter for water treatment used in the rinse of most endoscopes 54 (90.0%) and to dry the internal channels only 6 (10.0%) of them used compressed air. Adequate storing conditions were identified. CONCLUSION: Considering the particularities of the endoscope and its reprocessing, it is imperative to establish protocols to ensure the quality of the disinfection and the prevention of cross-contamination.Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia e Outras Especialidades - IBEPEGE. 2010-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032010000300002Arquivos de Gastroenterologia v.47 n.3 2010reponame:Arquivos de gastroenterologia (Online)instname:Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologiainstacron:IBEPEGE10.1590/S0004-28032010000300002info:eu-repo/semantics/openAccessBarbosa,Jackeline MacielSouza,Adenicía Custódia SilvaTipple,Anaclara Ferreira VeigaPimenta,Fabiana CristinaLeão,Lara Stefania Netto de OliveiraSilva,Silvia Rita Marin Caninnieng2010-12-03T00:00:00Zoai:scielo:S0004-28032010000300002Revistahttp://www.scielo.br/aghttps://old.scielo.br/oai/scielo-oai.php||secretariaarqgastr@hospitaligesp.com.br1678-42190004-2803opendoar:2010-12-03T00:00Arquivos de gastroenterologia (Online) - Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologiafalse |
dc.title.none.fl_str_mv |
Endoscope reprocessing using glutaraldehyde in endoscopy services of Goiânia, Brazil |
title |
Endoscope reprocessing using glutaraldehyde in endoscopy services of Goiânia, Brazil |
spellingShingle |
Endoscope reprocessing using glutaraldehyde in endoscopy services of Goiânia, Brazil Barbosa,Jackeline Maciel Endoscopes, gastrointestinal Disinfection Equipment contamination Glutaral |
title_short |
Endoscope reprocessing using glutaraldehyde in endoscopy services of Goiânia, Brazil |
title_full |
Endoscope reprocessing using glutaraldehyde in endoscopy services of Goiânia, Brazil |
title_fullStr |
Endoscope reprocessing using glutaraldehyde in endoscopy services of Goiânia, Brazil |
title_full_unstemmed |
Endoscope reprocessing using glutaraldehyde in endoscopy services of Goiânia, Brazil |
title_sort |
Endoscope reprocessing using glutaraldehyde in endoscopy services of Goiânia, Brazil |
author |
Barbosa,Jackeline Maciel |
author_facet |
Barbosa,Jackeline Maciel Souza,Adenicía Custódia Silva Tipple,Anaclara Ferreira Veiga Pimenta,Fabiana Cristina Leão,Lara Stefania Netto de Oliveira Silva,Silvia Rita Marin Caninni |
author_role |
author |
author2 |
Souza,Adenicía Custódia Silva Tipple,Anaclara Ferreira Veiga Pimenta,Fabiana Cristina Leão,Lara Stefania Netto de Oliveira Silva,Silvia Rita Marin Caninni |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Barbosa,Jackeline Maciel Souza,Adenicía Custódia Silva Tipple,Anaclara Ferreira Veiga Pimenta,Fabiana Cristina Leão,Lara Stefania Netto de Oliveira Silva,Silvia Rita Marin Caninni |
dc.subject.por.fl_str_mv |
Endoscopes, gastrointestinal Disinfection Equipment contamination Glutaral |
topic |
Endoscopes, gastrointestinal Disinfection Equipment contamination Glutaral |
description |
CONTEXT: The endoscopic procedure safety depends on the use of an adequately reprocessed device which quality is related to each of its operational steps. OBJECTIVE: To characterize the reprocessing of endoscopes using glutaraldehyde in endoscopy services METHODS: Study was conducted by observing the reprocessing of 60 endoscopes from 20 medical practices of the municipality of Goiânia, GO, central area of Brazil. RESULTS: This study showed failure in all reprocessing steps. The pre-washing was performed in 24 (40.0%) of the endoscope. In the cleaning steps, was identify the improper use of enzymatic detergent, and in 27 (45.0%) cases, the brushing of internal channels was not performed. All 60 endoscopes were submitted to this disinfectant. However, for 33 (55.0%) of the cases the internal channels was not filled. The total immersion of endoscope in the glutaraldehyde was not performed in 39 (65.0%) cases. The recommended minimum total immersion time for exposure to 2% glutaraldehyde solution was followed only for 12 (20.0%) endoscopes. There was no filter for water treatment used in the rinse of most endoscopes 54 (90.0%) and to dry the internal channels only 6 (10.0%) of them used compressed air. Adequate storing conditions were identified. CONCLUSION: Considering the particularities of the endoscope and its reprocessing, it is imperative to establish protocols to ensure the quality of the disinfection and the prevention of cross-contamination. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032010000300002 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032010000300002 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0004-28032010000300002 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia e Outras Especialidades - IBEPEGE. |
publisher.none.fl_str_mv |
Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia e Outras Especialidades - IBEPEGE. |
dc.source.none.fl_str_mv |
Arquivos de Gastroenterologia v.47 n.3 2010 reponame:Arquivos de gastroenterologia (Online) instname:Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia instacron:IBEPEGE |
instname_str |
Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia |
instacron_str |
IBEPEGE |
institution |
IBEPEGE |
reponame_str |
Arquivos de gastroenterologia (Online) |
collection |
Arquivos de gastroenterologia (Online) |
repository.name.fl_str_mv |
Arquivos de gastroenterologia (Online) - Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia |
repository.mail.fl_str_mv |
||secretariaarqgastr@hospitaligesp.com.br |
_version_ |
1754193345544978432 |