Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns

Detalhes bibliográficos
Autor(a) principal: XAVIER,E. M.
Data de Publicação: 2019
Outros Autores: R. NETO,J. G., SARMANHO,A. M. C., ROQUETE,L., PAULA,L. G. C. De
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista IBRACON de Estruturas e Materiais
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000200337
Resumo: Abstract This paper presents experimental and theoretical analysis of bolts employed as shear connectors in circular concrete-filled steel tube columns (CFTs). The theoretical results, obtained from ABNT NBR 16239:2013 formulations, were compared with the experimental results. A series of push-out tests were carried out, where the diameter and length of the bolts, the number of connectors and the concrete strength were varied. From the experimental results, it was observed that the equations from ABNT NBR 16239:2013 are conservative. Therefore, it is proposed an adjustment to the formulations in order to consider the concrete confinement. It was also verified that increments in the diameter and the length of the bolt increase the load capacity of the connector. However, the variation of the quantity of bolts and the concrete strength did not interfere in the load capacity.
id IBRACON-1_0d3724588c0a1f84a504be3897fb42ec
oai_identifier_str oai:scielo:S1983-41952019000200337
network_acronym_str IBRACON-1
network_name_str Revista IBRACON de Estruturas e Materiais
repository_id_str
spelling Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columnsconcrete-filled tube columnscircular tubular sectionshear connectorboltAbstract This paper presents experimental and theoretical analysis of bolts employed as shear connectors in circular concrete-filled steel tube columns (CFTs). The theoretical results, obtained from ABNT NBR 16239:2013 formulations, were compared with the experimental results. A series of push-out tests were carried out, where the diameter and length of the bolts, the number of connectors and the concrete strength were varied. From the experimental results, it was observed that the equations from ABNT NBR 16239:2013 are conservative. Therefore, it is proposed an adjustment to the formulations in order to consider the concrete confinement. It was also verified that increments in the diameter and the length of the bolt increase the load capacity of the connector. However, the variation of the quantity of bolts and the concrete strength did not interfere in the load capacity.IBRACON - Instituto Brasileiro do Concreto2019-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000200337Revista IBRACON de Estruturas e Materiais v.12 n.2 2019reponame:Revista IBRACON de Estruturas e Materiaisinstname:Instituto Brasileiro do Concreto (IBRACON)instacron:IBRACON10.1590/s1983-41952019000200008info:eu-repo/semantics/openAccessXAVIER,E. M.R. NETO,J. G.SARMANHO,A. M. C.ROQUETE,L.PAULA,L. G. C. Deeng2019-05-17T00:00:00Zoai:scielo:S1983-41952019000200337Revistahttp://www.revistas.ibracon.org.br/index.php/riemhttps://old.scielo.br/oai/scielo-oai.phpeditores.riem@gmail.com||arlene@ibracon.org.br1983-41951983-4195opendoar:2019-05-17T00:00Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)false
dc.title.none.fl_str_mv Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns
title Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns
spellingShingle Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns
XAVIER,E. M.
concrete-filled tube columns
circular tubular section
shear connector
bolt
title_short Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns
title_full Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns
title_fullStr Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns
title_full_unstemmed Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns
title_sort Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns
author XAVIER,E. M.
author_facet XAVIER,E. M.
R. NETO,J. G.
SARMANHO,A. M. C.
ROQUETE,L.
PAULA,L. G. C. De
author_role author
author2 R. NETO,J. G.
SARMANHO,A. M. C.
ROQUETE,L.
PAULA,L. G. C. De
author2_role author
author
author
author
dc.contributor.author.fl_str_mv XAVIER,E. M.
R. NETO,J. G.
SARMANHO,A. M. C.
ROQUETE,L.
PAULA,L. G. C. De
dc.subject.por.fl_str_mv concrete-filled tube columns
circular tubular section
shear connector
bolt
topic concrete-filled tube columns
circular tubular section
shear connector
bolt
description Abstract This paper presents experimental and theoretical analysis of bolts employed as shear connectors in circular concrete-filled steel tube columns (CFTs). The theoretical results, obtained from ABNT NBR 16239:2013 formulations, were compared with the experimental results. A series of push-out tests were carried out, where the diameter and length of the bolts, the number of connectors and the concrete strength were varied. From the experimental results, it was observed that the equations from ABNT NBR 16239:2013 are conservative. Therefore, it is proposed an adjustment to the formulations in order to consider the concrete confinement. It was also verified that increments in the diameter and the length of the bolt increase the load capacity of the connector. However, the variation of the quantity of bolts and the concrete strength did not interfere in the load capacity.
publishDate 2019
dc.date.none.fl_str_mv 2019-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000200337
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000200337
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1983-41952019000200008
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
dc.source.none.fl_str_mv Revista IBRACON de Estruturas e Materiais v.12 n.2 2019
reponame:Revista IBRACON de Estruturas e Materiais
instname:Instituto Brasileiro do Concreto (IBRACON)
instacron:IBRACON
instname_str Instituto Brasileiro do Concreto (IBRACON)
instacron_str IBRACON
institution IBRACON
reponame_str Revista IBRACON de Estruturas e Materiais
collection Revista IBRACON de Estruturas e Materiais
repository.name.fl_str_mv Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)
repository.mail.fl_str_mv editores.riem@gmail.com||arlene@ibracon.org.br
_version_ 1754193605630623744