Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista IBRACON de Estruturas e Materiais |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000200337 |
Resumo: | Abstract This paper presents experimental and theoretical analysis of bolts employed as shear connectors in circular concrete-filled steel tube columns (CFTs). The theoretical results, obtained from ABNT NBR 16239:2013 formulations, were compared with the experimental results. A series of push-out tests were carried out, where the diameter and length of the bolts, the number of connectors and the concrete strength were varied. From the experimental results, it was observed that the equations from ABNT NBR 16239:2013 are conservative. Therefore, it is proposed an adjustment to the formulations in order to consider the concrete confinement. It was also verified that increments in the diameter and the length of the bolt increase the load capacity of the connector. However, the variation of the quantity of bolts and the concrete strength did not interfere in the load capacity. |
id |
IBRACON-1_0d3724588c0a1f84a504be3897fb42ec |
---|---|
oai_identifier_str |
oai:scielo:S1983-41952019000200337 |
network_acronym_str |
IBRACON-1 |
network_name_str |
Revista IBRACON de Estruturas e Materiais |
repository_id_str |
|
spelling |
Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columnsconcrete-filled tube columnscircular tubular sectionshear connectorboltAbstract This paper presents experimental and theoretical analysis of bolts employed as shear connectors in circular concrete-filled steel tube columns (CFTs). The theoretical results, obtained from ABNT NBR 16239:2013 formulations, were compared with the experimental results. A series of push-out tests were carried out, where the diameter and length of the bolts, the number of connectors and the concrete strength were varied. From the experimental results, it was observed that the equations from ABNT NBR 16239:2013 are conservative. Therefore, it is proposed an adjustment to the formulations in order to consider the concrete confinement. It was also verified that increments in the diameter and the length of the bolt increase the load capacity of the connector. However, the variation of the quantity of bolts and the concrete strength did not interfere in the load capacity.IBRACON - Instituto Brasileiro do Concreto2019-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000200337Revista IBRACON de Estruturas e Materiais v.12 n.2 2019reponame:Revista IBRACON de Estruturas e Materiaisinstname:Instituto Brasileiro do Concreto (IBRACON)instacron:IBRACON10.1590/s1983-41952019000200008info:eu-repo/semantics/openAccessXAVIER,E. M.R. NETO,J. G.SARMANHO,A. M. C.ROQUETE,L.PAULA,L. G. C. Deeng2019-05-17T00:00:00Zoai:scielo:S1983-41952019000200337Revistahttp://www.revistas.ibracon.org.br/index.php/riemhttps://old.scielo.br/oai/scielo-oai.phpeditores.riem@gmail.com||arlene@ibracon.org.br1983-41951983-4195opendoar:2019-05-17T00:00Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)false |
dc.title.none.fl_str_mv |
Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns |
title |
Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns |
spellingShingle |
Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns XAVIER,E. M. concrete-filled tube columns circular tubular section shear connector bolt |
title_short |
Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns |
title_full |
Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns |
title_fullStr |
Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns |
title_full_unstemmed |
Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns |
title_sort |
Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns |
author |
XAVIER,E. M. |
author_facet |
XAVIER,E. M. R. NETO,J. G. SARMANHO,A. M. C. ROQUETE,L. PAULA,L. G. C. De |
author_role |
author |
author2 |
R. NETO,J. G. SARMANHO,A. M. C. ROQUETE,L. PAULA,L. G. C. De |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
XAVIER,E. M. R. NETO,J. G. SARMANHO,A. M. C. ROQUETE,L. PAULA,L. G. C. De |
dc.subject.por.fl_str_mv |
concrete-filled tube columns circular tubular section shear connector bolt |
topic |
concrete-filled tube columns circular tubular section shear connector bolt |
description |
Abstract This paper presents experimental and theoretical analysis of bolts employed as shear connectors in circular concrete-filled steel tube columns (CFTs). The theoretical results, obtained from ABNT NBR 16239:2013 formulations, were compared with the experimental results. A series of push-out tests were carried out, where the diameter and length of the bolts, the number of connectors and the concrete strength were varied. From the experimental results, it was observed that the equations from ABNT NBR 16239:2013 are conservative. Therefore, it is proposed an adjustment to the formulations in order to consider the concrete confinement. It was also verified that increments in the diameter and the length of the bolt increase the load capacity of the connector. However, the variation of the quantity of bolts and the concrete strength did not interfere in the load capacity. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000200337 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000200337 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/s1983-41952019000200008 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
IBRACON - Instituto Brasileiro do Concreto |
publisher.none.fl_str_mv |
IBRACON - Instituto Brasileiro do Concreto |
dc.source.none.fl_str_mv |
Revista IBRACON de Estruturas e Materiais v.12 n.2 2019 reponame:Revista IBRACON de Estruturas e Materiais instname:Instituto Brasileiro do Concreto (IBRACON) instacron:IBRACON |
instname_str |
Instituto Brasileiro do Concreto (IBRACON) |
instacron_str |
IBRACON |
institution |
IBRACON |
reponame_str |
Revista IBRACON de Estruturas e Materiais |
collection |
Revista IBRACON de Estruturas e Materiais |
repository.name.fl_str_mv |
Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON) |
repository.mail.fl_str_mv |
editores.riem@gmail.com||arlene@ibracon.org.br |
_version_ |
1754193605630623744 |