Economic viability of ultra high-performance fiber reinforced concrete in prestressed concrete wind towers to support a 5 MW turbine

Detalhes bibliográficos
Autor(a) principal: GAMA,P. V. C. N.
Data de Publicação: 2017
Outros Autores: BITTENCOURT,T. N.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista IBRACON de Estruturas e Materiais
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952017000100002
Resumo: Abstract The Ultra-High Performance Fiber-Reinforced Concrete is a material with remarkable mechanical properties and durability when compared to conventional and high performance concrete, which allows its use even without the reinforcement. This paper proposes the design of prestressed towers for a 5 MW turbine, through regulatory provisions and the limit states method, with UHPFRC and the concrete class C50, comparing the differences obtained in the design by parametric analysis, giving the advantages and disadvantages of using this new type of concrete. Important considerations, simplifications and notes are made to the calculation process, as well as in obtaining the prestressing and passive longitudinal and passive transverse reinforcement, highlighting the shear strength of annular sections comparing a model proposed here with recent experimental results present in the literature, which was obtained good agreement. In the end, it is estimated a first value within the constraints here made to ensure the economic viability of the use of UHPFRC in a 100 m prestressed wind tower with a 5 MW turbine.
id IBRACON-1_14bd87b8286c94b62759be0c25b5e5d2
oai_identifier_str oai:scielo:S1983-41952017000100002
network_acronym_str IBRACON-1
network_name_str Revista IBRACON de Estruturas e Materiais
repository_id_str
spelling Economic viability of ultra high-performance fiber reinforced concrete in prestressed concrete wind towers to support a 5 MW turbineUltra-high performance fiber-reinforced concreteUHPFRCprestressed wind towersshear strengthdesignAbstract The Ultra-High Performance Fiber-Reinforced Concrete is a material with remarkable mechanical properties and durability when compared to conventional and high performance concrete, which allows its use even without the reinforcement. This paper proposes the design of prestressed towers for a 5 MW turbine, through regulatory provisions and the limit states method, with UHPFRC and the concrete class C50, comparing the differences obtained in the design by parametric analysis, giving the advantages and disadvantages of using this new type of concrete. Important considerations, simplifications and notes are made to the calculation process, as well as in obtaining the prestressing and passive longitudinal and passive transverse reinforcement, highlighting the shear strength of annular sections comparing a model proposed here with recent experimental results present in the literature, which was obtained good agreement. In the end, it is estimated a first value within the constraints here made to ensure the economic viability of the use of UHPFRC in a 100 m prestressed wind tower with a 5 MW turbine.IBRACON - Instituto Brasileiro do Concreto2017-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952017000100002Revista IBRACON de Estruturas e Materiais v.10 n.1 2017reponame:Revista IBRACON de Estruturas e Materiaisinstname:Instituto Brasileiro do Concreto (IBRACON)instacron:IBRACON10.1590/s1983-41952017000100002info:eu-repo/semantics/openAccessGAMA,P. V. C. N.BITTENCOURT,T. N.eng2017-04-03T00:00:00Zoai:scielo:S1983-41952017000100002Revistahttp://www.revistas.ibracon.org.br/index.php/riemhttps://old.scielo.br/oai/scielo-oai.phpeditores.riem@gmail.com||arlene@ibracon.org.br1983-41951983-4195opendoar:2017-04-03T00:00Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)false
dc.title.none.fl_str_mv Economic viability of ultra high-performance fiber reinforced concrete in prestressed concrete wind towers to support a 5 MW turbine
title Economic viability of ultra high-performance fiber reinforced concrete in prestressed concrete wind towers to support a 5 MW turbine
spellingShingle Economic viability of ultra high-performance fiber reinforced concrete in prestressed concrete wind towers to support a 5 MW turbine
GAMA,P. V. C. N.
Ultra-high performance fiber-reinforced concrete
UHPFRC
prestressed wind towers
shear strength
design
title_short Economic viability of ultra high-performance fiber reinforced concrete in prestressed concrete wind towers to support a 5 MW turbine
title_full Economic viability of ultra high-performance fiber reinforced concrete in prestressed concrete wind towers to support a 5 MW turbine
title_fullStr Economic viability of ultra high-performance fiber reinforced concrete in prestressed concrete wind towers to support a 5 MW turbine
title_full_unstemmed Economic viability of ultra high-performance fiber reinforced concrete in prestressed concrete wind towers to support a 5 MW turbine
title_sort Economic viability of ultra high-performance fiber reinforced concrete in prestressed concrete wind towers to support a 5 MW turbine
author GAMA,P. V. C. N.
author_facet GAMA,P. V. C. N.
BITTENCOURT,T. N.
author_role author
author2 BITTENCOURT,T. N.
author2_role author
dc.contributor.author.fl_str_mv GAMA,P. V. C. N.
BITTENCOURT,T. N.
dc.subject.por.fl_str_mv Ultra-high performance fiber-reinforced concrete
UHPFRC
prestressed wind towers
shear strength
design
topic Ultra-high performance fiber-reinforced concrete
UHPFRC
prestressed wind towers
shear strength
design
description Abstract The Ultra-High Performance Fiber-Reinforced Concrete is a material with remarkable mechanical properties and durability when compared to conventional and high performance concrete, which allows its use even without the reinforcement. This paper proposes the design of prestressed towers for a 5 MW turbine, through regulatory provisions and the limit states method, with UHPFRC and the concrete class C50, comparing the differences obtained in the design by parametric analysis, giving the advantages and disadvantages of using this new type of concrete. Important considerations, simplifications and notes are made to the calculation process, as well as in obtaining the prestressing and passive longitudinal and passive transverse reinforcement, highlighting the shear strength of annular sections comparing a model proposed here with recent experimental results present in the literature, which was obtained good agreement. In the end, it is estimated a first value within the constraints here made to ensure the economic viability of the use of UHPFRC in a 100 m prestressed wind tower with a 5 MW turbine.
publishDate 2017
dc.date.none.fl_str_mv 2017-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952017000100002
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952017000100002
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1983-41952017000100002
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
dc.source.none.fl_str_mv Revista IBRACON de Estruturas e Materiais v.10 n.1 2017
reponame:Revista IBRACON de Estruturas e Materiais
instname:Instituto Brasileiro do Concreto (IBRACON)
instacron:IBRACON
instname_str Instituto Brasileiro do Concreto (IBRACON)
instacron_str IBRACON
institution IBRACON
reponame_str Revista IBRACON de Estruturas e Materiais
collection Revista IBRACON de Estruturas e Materiais
repository.name.fl_str_mv Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)
repository.mail.fl_str_mv editores.riem@gmail.com||arlene@ibracon.org.br
_version_ 1754193605164007424