Experimental analysis of load capacity in beams with steel fiber reinforcement on the compression face

Detalhes bibliográficos
Autor(a) principal: DEGHENHARD,C. C.
Data de Publicação: 2019
Outros Autores: SILVA,B. V., PELISSER,F.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista IBRACON de Estruturas e Materiais
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000100069
Resumo: Abstract The use of steel fibers in the concrete is mainly aimed at increasing the post-peak toughness, due to the adhesion of the fibers to the cementitious matrix. However, there are several typologies of steel fibers, and the main differences are in the form (relation between length and diameter), fiber geometry, and the characterization between macrofibers and microfibers, which generally serve to reduce macrocracking and microcracking, respectively. In this context, this work evaluated the use of microfibers (20 kg/m³ or volume equal to 0.26% (Vf) of concrete volume), macrofibers (20 kg/m³ or Vf = 0.26%) and hybridization (10 kg/m³) + macrofibers (10 kg/m³) inserted in a high strength concrete (fc = 80 MPa). Two types of steel fibers were used: macrofibers with a diameter of 0.75 mm and a length of 60 mm (a form factor of 80); and microfibers with a diameter of 200 μm and a length of 13 mm (a form factor of 65). The fibers were used in concrete to act as a reinforcement on the compression face of reinforced beams (12×20×160cm), and the mechanical characteristics of the concretes were analyzed: (i) flexural strength in prismatic specimens (10×10×35 cm), (ii) compressive strength in cylindrical specimens (20×Ø10 cm) and (iii) modulus of elasticity in cylindrical specimens (20×Ø10 cm). Analysis of the results showed that compressive strength increased by approximately 8% for all the compositions with fibers compared with concrete without fibers. Similar behavior was verified for the modulus of elasticity. In the prismatic specimens (10×10×35 cm) an increase in toughness was observed, with the macrofibers performing better. In beams measuring 12×20×160 cm, an increase in bearing capacity was verified regarding cracking time and plastic rotation, with the best result also obtained using macrofibers. Overall, it can be concluded that the application of reinforcement with steel fibers in the compression face of beams was efficient, even though it did not present a significant increase in compressive strength, a fact that could be correlated with the reduced volume of fibers used.
id IBRACON-1_62230351227c8503df41eae93c6e08f0
oai_identifier_str oai:scielo:S1983-41952019000100069
network_acronym_str IBRACON-1
network_name_str Revista IBRACON de Estruturas e Materiais
repository_id_str
spelling Experimental analysis of load capacity in beams with steel fiber reinforcement on the compression facereinforcementhigh-performance concretesteel fibersmicrofibersmacrofibersAbstract The use of steel fibers in the concrete is mainly aimed at increasing the post-peak toughness, due to the adhesion of the fibers to the cementitious matrix. However, there are several typologies of steel fibers, and the main differences are in the form (relation between length and diameter), fiber geometry, and the characterization between macrofibers and microfibers, which generally serve to reduce macrocracking and microcracking, respectively. In this context, this work evaluated the use of microfibers (20 kg/m³ or volume equal to 0.26% (Vf) of concrete volume), macrofibers (20 kg/m³ or Vf = 0.26%) and hybridization (10 kg/m³) + macrofibers (10 kg/m³) inserted in a high strength concrete (fc = 80 MPa). Two types of steel fibers were used: macrofibers with a diameter of 0.75 mm and a length of 60 mm (a form factor of 80); and microfibers with a diameter of 200 μm and a length of 13 mm (a form factor of 65). The fibers were used in concrete to act as a reinforcement on the compression face of reinforced beams (12×20×160cm), and the mechanical characteristics of the concretes were analyzed: (i) flexural strength in prismatic specimens (10×10×35 cm), (ii) compressive strength in cylindrical specimens (20×Ø10 cm) and (iii) modulus of elasticity in cylindrical specimens (20×Ø10 cm). Analysis of the results showed that compressive strength increased by approximately 8% for all the compositions with fibers compared with concrete without fibers. Similar behavior was verified for the modulus of elasticity. In the prismatic specimens (10×10×35 cm) an increase in toughness was observed, with the macrofibers performing better. In beams measuring 12×20×160 cm, an increase in bearing capacity was verified regarding cracking time and plastic rotation, with the best result also obtained using macrofibers. Overall, it can be concluded that the application of reinforcement with steel fibers in the compression face of beams was efficient, even though it did not present a significant increase in compressive strength, a fact that could be correlated with the reduced volume of fibers used.IBRACON - Instituto Brasileiro do Concreto2019-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000100069Revista IBRACON de Estruturas e Materiais v.12 n.1 2019reponame:Revista IBRACON de Estruturas e Materiaisinstname:Instituto Brasileiro do Concreto (IBRACON)instacron:IBRACON10.1590/s1983-41952019000100007info:eu-repo/semantics/openAccessDEGHENHARD,C. C.SILVA,B. V.PELISSER,F.eng2019-03-18T00:00:00Zoai:scielo:S1983-41952019000100069Revistahttp://www.revistas.ibracon.org.br/index.php/riemhttps://old.scielo.br/oai/scielo-oai.phpeditores.riem@gmail.com||arlene@ibracon.org.br1983-41951983-4195opendoar:2019-03-18T00:00Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)false
dc.title.none.fl_str_mv Experimental analysis of load capacity in beams with steel fiber reinforcement on the compression face
title Experimental analysis of load capacity in beams with steel fiber reinforcement on the compression face
spellingShingle Experimental analysis of load capacity in beams with steel fiber reinforcement on the compression face
DEGHENHARD,C. C.
reinforcement
high-performance concrete
steel fibers
microfibers
macrofibers
title_short Experimental analysis of load capacity in beams with steel fiber reinforcement on the compression face
title_full Experimental analysis of load capacity in beams with steel fiber reinforcement on the compression face
title_fullStr Experimental analysis of load capacity in beams with steel fiber reinforcement on the compression face
title_full_unstemmed Experimental analysis of load capacity in beams with steel fiber reinforcement on the compression face
title_sort Experimental analysis of load capacity in beams with steel fiber reinforcement on the compression face
author DEGHENHARD,C. C.
author_facet DEGHENHARD,C. C.
SILVA,B. V.
PELISSER,F.
author_role author
author2 SILVA,B. V.
PELISSER,F.
author2_role author
author
dc.contributor.author.fl_str_mv DEGHENHARD,C. C.
SILVA,B. V.
PELISSER,F.
dc.subject.por.fl_str_mv reinforcement
high-performance concrete
steel fibers
microfibers
macrofibers
topic reinforcement
high-performance concrete
steel fibers
microfibers
macrofibers
description Abstract The use of steel fibers in the concrete is mainly aimed at increasing the post-peak toughness, due to the adhesion of the fibers to the cementitious matrix. However, there are several typologies of steel fibers, and the main differences are in the form (relation between length and diameter), fiber geometry, and the characterization between macrofibers and microfibers, which generally serve to reduce macrocracking and microcracking, respectively. In this context, this work evaluated the use of microfibers (20 kg/m³ or volume equal to 0.26% (Vf) of concrete volume), macrofibers (20 kg/m³ or Vf = 0.26%) and hybridization (10 kg/m³) + macrofibers (10 kg/m³) inserted in a high strength concrete (fc = 80 MPa). Two types of steel fibers were used: macrofibers with a diameter of 0.75 mm and a length of 60 mm (a form factor of 80); and microfibers with a diameter of 200 μm and a length of 13 mm (a form factor of 65). The fibers were used in concrete to act as a reinforcement on the compression face of reinforced beams (12×20×160cm), and the mechanical characteristics of the concretes were analyzed: (i) flexural strength in prismatic specimens (10×10×35 cm), (ii) compressive strength in cylindrical specimens (20×Ø10 cm) and (iii) modulus of elasticity in cylindrical specimens (20×Ø10 cm). Analysis of the results showed that compressive strength increased by approximately 8% for all the compositions with fibers compared with concrete without fibers. Similar behavior was verified for the modulus of elasticity. In the prismatic specimens (10×10×35 cm) an increase in toughness was observed, with the macrofibers performing better. In beams measuring 12×20×160 cm, an increase in bearing capacity was verified regarding cracking time and plastic rotation, with the best result also obtained using macrofibers. Overall, it can be concluded that the application of reinforcement with steel fibers in the compression face of beams was efficient, even though it did not present a significant increase in compressive strength, a fact that could be correlated with the reduced volume of fibers used.
publishDate 2019
dc.date.none.fl_str_mv 2019-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000100069
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000100069
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1983-41952019000100007
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
dc.source.none.fl_str_mv Revista IBRACON de Estruturas e Materiais v.12 n.1 2019
reponame:Revista IBRACON de Estruturas e Materiais
instname:Instituto Brasileiro do Concreto (IBRACON)
instacron:IBRACON
instname_str Instituto Brasileiro do Concreto (IBRACON)
instacron_str IBRACON
institution IBRACON
reponame_str Revista IBRACON de Estruturas e Materiais
collection Revista IBRACON de Estruturas e Materiais
repository.name.fl_str_mv Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)
repository.mail.fl_str_mv editores.riem@gmail.com||arlene@ibracon.org.br
_version_ 1754193605609652224