Case study: influence of performance levels of ABNT NBR 15575 without consumption of materials used in reinforced concrete structures

Detalhes bibliográficos
Autor(a) principal: CUNHA,F. S.
Data de Publicação: 2019
Outros Autores: COLLA,K. A. L., EHRENBRING,H., BOLINA,F. L., TUTIKIAN,B.
Tipo de documento: Relatório
Idioma: eng
Título da fonte: Revista IBRACON de Estruturas e Materiais
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000400956
Resumo: Abstract The Brazilian construction industry still discusses the consequence of the Performance Standard on housing developments. According to ABNT NBR 15575 [1], the systems that compose residential buildings need to meet minimum performance requirements. Among the systems, the structural must reach a minimum Service Life (SL) of 50 years, or intermediate or higher that corresponds to 63 and 75 years, respectively. The industry also debates the impact and viability of increasing the SL of reinforced concrete structures. Therefore, this article aimed to analyze a single reinforced concrete building designed for the 3 SL specified by ABNT NBR 15575 [1]. The study focused on the total consumption of steel and concrete. The structure’s designed conditions of exposure were varied for each performance level, based on the 4 environmental exposure classes (EEC) of ABNT NBR 6118 [3] and ABNT NBR 12655 [11], totalizing 12 situations. It was noted that the increased performance level increases consumption of materials, and the designs made for EEC IV consumed 12.3% and 16.2% more steel and concrete at the intermediate and superior performance levels respectively, when compared to the minimum performance level.
id IBRACON-1_664558893fe8713a18114cb7d342701b
oai_identifier_str oai:scielo:S1983-41952019000400956
network_acronym_str IBRACON-1
network_name_str Revista IBRACON de Estruturas e Materiais
repository_id_str
spelling Case study: influence of performance levels of ABNT NBR 15575 without consumption of materials used in reinforced concrete structuresbrazilian performance standardconcrete strcutureservice lifeAbstract The Brazilian construction industry still discusses the consequence of the Performance Standard on housing developments. According to ABNT NBR 15575 [1], the systems that compose residential buildings need to meet minimum performance requirements. Among the systems, the structural must reach a minimum Service Life (SL) of 50 years, or intermediate or higher that corresponds to 63 and 75 years, respectively. The industry also debates the impact and viability of increasing the SL of reinforced concrete structures. Therefore, this article aimed to analyze a single reinforced concrete building designed for the 3 SL specified by ABNT NBR 15575 [1]. The study focused on the total consumption of steel and concrete. The structure’s designed conditions of exposure were varied for each performance level, based on the 4 environmental exposure classes (EEC) of ABNT NBR 6118 [3] and ABNT NBR 12655 [11], totalizing 12 situations. It was noted that the increased performance level increases consumption of materials, and the designs made for EEC IV consumed 12.3% and 16.2% more steel and concrete at the intermediate and superior performance levels respectively, when compared to the minimum performance level.IBRACON - Instituto Brasileiro do Concreto2019-08-01info:eu-repo/semantics/reportinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000400956Revista IBRACON de Estruturas e Materiais v.12 n.4 2019reponame:Revista IBRACON de Estruturas e Materiaisinstname:Instituto Brasileiro do Concreto (IBRACON)instacron:IBRACON10.1590/s1983-41952019000400013info:eu-repo/semantics/openAccessCUNHA,F. S.COLLA,K. A. L.EHRENBRING,H.BOLINA,F. L.TUTIKIAN,B.eng2019-09-19T00:00:00Zoai:scielo:S1983-41952019000400956Revistahttp://www.revistas.ibracon.org.br/index.php/riemhttps://old.scielo.br/oai/scielo-oai.phpeditores.riem@gmail.com||arlene@ibracon.org.br1983-41951983-4195opendoar:2019-09-19T00:00Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)false
dc.title.none.fl_str_mv Case study: influence of performance levels of ABNT NBR 15575 without consumption of materials used in reinforced concrete structures
title Case study: influence of performance levels of ABNT NBR 15575 without consumption of materials used in reinforced concrete structures
spellingShingle Case study: influence of performance levels of ABNT NBR 15575 without consumption of materials used in reinforced concrete structures
CUNHA,F. S.
brazilian performance standard
concrete strcuture
service life
title_short Case study: influence of performance levels of ABNT NBR 15575 without consumption of materials used in reinforced concrete structures
title_full Case study: influence of performance levels of ABNT NBR 15575 without consumption of materials used in reinforced concrete structures
title_fullStr Case study: influence of performance levels of ABNT NBR 15575 without consumption of materials used in reinforced concrete structures
title_full_unstemmed Case study: influence of performance levels of ABNT NBR 15575 without consumption of materials used in reinforced concrete structures
title_sort Case study: influence of performance levels of ABNT NBR 15575 without consumption of materials used in reinforced concrete structures
author CUNHA,F. S.
author_facet CUNHA,F. S.
COLLA,K. A. L.
EHRENBRING,H.
BOLINA,F. L.
TUTIKIAN,B.
author_role author
author2 COLLA,K. A. L.
EHRENBRING,H.
BOLINA,F. L.
TUTIKIAN,B.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv CUNHA,F. S.
COLLA,K. A. L.
EHRENBRING,H.
BOLINA,F. L.
TUTIKIAN,B.
dc.subject.por.fl_str_mv brazilian performance standard
concrete strcuture
service life
topic brazilian performance standard
concrete strcuture
service life
description Abstract The Brazilian construction industry still discusses the consequence of the Performance Standard on housing developments. According to ABNT NBR 15575 [1], the systems that compose residential buildings need to meet minimum performance requirements. Among the systems, the structural must reach a minimum Service Life (SL) of 50 years, or intermediate or higher that corresponds to 63 and 75 years, respectively. The industry also debates the impact and viability of increasing the SL of reinforced concrete structures. Therefore, this article aimed to analyze a single reinforced concrete building designed for the 3 SL specified by ABNT NBR 15575 [1]. The study focused on the total consumption of steel and concrete. The structure’s designed conditions of exposure were varied for each performance level, based on the 4 environmental exposure classes (EEC) of ABNT NBR 6118 [3] and ABNT NBR 12655 [11], totalizing 12 situations. It was noted that the increased performance level increases consumption of materials, and the designs made for EEC IV consumed 12.3% and 16.2% more steel and concrete at the intermediate and superior performance levels respectively, when compared to the minimum performance level.
publishDate 2019
dc.date.none.fl_str_mv 2019-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/report
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format report
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000400956
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000400956
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1983-41952019000400013
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
dc.source.none.fl_str_mv Revista IBRACON de Estruturas e Materiais v.12 n.4 2019
reponame:Revista IBRACON de Estruturas e Materiais
instname:Instituto Brasileiro do Concreto (IBRACON)
instacron:IBRACON
instname_str Instituto Brasileiro do Concreto (IBRACON)
instacron_str IBRACON
institution IBRACON
reponame_str Revista IBRACON de Estruturas e Materiais
collection Revista IBRACON de Estruturas e Materiais
repository.name.fl_str_mv Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)
repository.mail.fl_str_mv editores.riem@gmail.com||arlene@ibracon.org.br
_version_ 1754193605675712512