Influence of the type of measuring device in determining the static modulus of elasticity of concrete

Detalhes bibliográficos
Autor(a) principal: Araújo,S. S.
Data de Publicação: 2012
Outros Autores: Guimarães,G. N., Geyer,A. L. B.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista IBRACON de Estruturas e Materiais
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952012000500001
Resumo: This paper presents a comparative analysis of the results obtained in static modulus of elasticity tests of plain concrete cylindrical specimens. The purpose of this study is to identify and evaluate the influence of several factors involved in modulus of elasticity tests such as the strain measurement device used (dial indicators, electrical surface bonded strain gages, externally fixed strain gages and linear variation displacement transducer - LVDT), the type of concrete (Class C30 and Class C60) and cylindrical specimen size (100 mm x 200 mm and 150 mm x 300 mm). The modulus tests were done in two different laboratories in the Goiânia, GO region and were performed according to code ABNT NBR 8522:2008, which describes the initial tangent modulus test, characterized by strains measured at tension values of 0.5 MPa and 30% of the ultimate load. One hundred and sixty specimens were tested with statistically satisfactory results. It was concluded that the type of strain measurement device greatly influenced the modulus of elasticity results. Tests in specimens 100 mm x 200 mm showed highest statistical variation.
id IBRACON-1_7b18784f0d2daa6325ff9167c2068b9d
oai_identifier_str oai:scielo:S1983-41952012000500001
network_acronym_str IBRACON-1
network_name_str Revista IBRACON de Estruturas e Materiais
repository_id_str
spelling Influence of the type of measuring device in determining the static modulus of elasticity of concreteconcretespecimen sizemeasurementmodulus of elasticityThis paper presents a comparative analysis of the results obtained in static modulus of elasticity tests of plain concrete cylindrical specimens. The purpose of this study is to identify and evaluate the influence of several factors involved in modulus of elasticity tests such as the strain measurement device used (dial indicators, electrical surface bonded strain gages, externally fixed strain gages and linear variation displacement transducer - LVDT), the type of concrete (Class C30 and Class C60) and cylindrical specimen size (100 mm x 200 mm and 150 mm x 300 mm). The modulus tests were done in two different laboratories in the Goiânia, GO region and were performed according to code ABNT NBR 8522:2008, which describes the initial tangent modulus test, characterized by strains measured at tension values of 0.5 MPa and 30% of the ultimate load. One hundred and sixty specimens were tested with statistically satisfactory results. It was concluded that the type of strain measurement device greatly influenced the modulus of elasticity results. Tests in specimens 100 mm x 200 mm showed highest statistical variation.IBRACON - Instituto Brasileiro do Concreto2012-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952012000500001Revista IBRACON de Estruturas e Materiais v.5 n.5 2012reponame:Revista IBRACON de Estruturas e Materiaisinstname:Instituto Brasileiro do Concreto (IBRACON)instacron:IBRACON10.1590/S1983-41952012000500001info:eu-repo/semantics/openAccessAraújo,S. S.Guimarães,G. N.Geyer,A. L. B.eng2012-10-11T00:00:00Zoai:scielo:S1983-41952012000500001Revistahttp://www.revistas.ibracon.org.br/index.php/riemhttps://old.scielo.br/oai/scielo-oai.phpeditores.riem@gmail.com||arlene@ibracon.org.br1983-41951983-4195opendoar:2012-10-11T00:00Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)false
dc.title.none.fl_str_mv Influence of the type of measuring device in determining the static modulus of elasticity of concrete
title Influence of the type of measuring device in determining the static modulus of elasticity of concrete
spellingShingle Influence of the type of measuring device in determining the static modulus of elasticity of concrete
Araújo,S. S.
concrete
specimen size
measurement
modulus of elasticity
title_short Influence of the type of measuring device in determining the static modulus of elasticity of concrete
title_full Influence of the type of measuring device in determining the static modulus of elasticity of concrete
title_fullStr Influence of the type of measuring device in determining the static modulus of elasticity of concrete
title_full_unstemmed Influence of the type of measuring device in determining the static modulus of elasticity of concrete
title_sort Influence of the type of measuring device in determining the static modulus of elasticity of concrete
author Araújo,S. S.
author_facet Araújo,S. S.
Guimarães,G. N.
Geyer,A. L. B.
author_role author
author2 Guimarães,G. N.
Geyer,A. L. B.
author2_role author
author
dc.contributor.author.fl_str_mv Araújo,S. S.
Guimarães,G. N.
Geyer,A. L. B.
dc.subject.por.fl_str_mv concrete
specimen size
measurement
modulus of elasticity
topic concrete
specimen size
measurement
modulus of elasticity
description This paper presents a comparative analysis of the results obtained in static modulus of elasticity tests of plain concrete cylindrical specimens. The purpose of this study is to identify and evaluate the influence of several factors involved in modulus of elasticity tests such as the strain measurement device used (dial indicators, electrical surface bonded strain gages, externally fixed strain gages and linear variation displacement transducer - LVDT), the type of concrete (Class C30 and Class C60) and cylindrical specimen size (100 mm x 200 mm and 150 mm x 300 mm). The modulus tests were done in two different laboratories in the Goiânia, GO region and were performed according to code ABNT NBR 8522:2008, which describes the initial tangent modulus test, characterized by strains measured at tension values of 0.5 MPa and 30% of the ultimate load. One hundred and sixty specimens were tested with statistically satisfactory results. It was concluded that the type of strain measurement device greatly influenced the modulus of elasticity results. Tests in specimens 100 mm x 200 mm showed highest statistical variation.
publishDate 2012
dc.date.none.fl_str_mv 2012-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952012000500001
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952012000500001
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1983-41952012000500001
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
dc.source.none.fl_str_mv Revista IBRACON de Estruturas e Materiais v.5 n.5 2012
reponame:Revista IBRACON de Estruturas e Materiais
instname:Instituto Brasileiro do Concreto (IBRACON)
instacron:IBRACON
instname_str Instituto Brasileiro do Concreto (IBRACON)
instacron_str IBRACON
institution IBRACON
reponame_str Revista IBRACON de Estruturas e Materiais
collection Revista IBRACON de Estruturas e Materiais
repository.name.fl_str_mv Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)
repository.mail.fl_str_mv editores.riem@gmail.com||arlene@ibracon.org.br
_version_ 1754193604377575424