Punching shear in concrete reinforced flat slabs with steel fibers and shear reinforcement
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista IBRACON de Estruturas e Materiais |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952018000501110 |
Resumo: | Abstract Steel fibers in reinforced concrete increase the performance of slab-column connection once they increase ductility and energy absorption capacity of the concrete. The use of fibers in flat slabs may increase strength and change the mode of failure. The objective of this work is to present an experimental evaluation of punching shear strength of reinforced concrete flat slab with steel fibers and punching shear reinforcement. Eight square slabs, size 1800 mm by 1800 mm by 130mm, were loaded until failure by punching shear around the column. The models were divided in two groups, depending on the type of the concrete used (with or without steel fibers). The steel fiber volume used in the slabs of second group was of 0.9%. Each group was composed of four slabs: one without shear reinforcement and three with shear reinforcement (studs) distributed radially around the column. The use of steel fibers increased the ultimate strength of all flat slabs. In one of the slabs, the association of steel fibers with shear reinforcement changed the failure surface from outside to inside the punching shear reinforcement region. |
id |
IBRACON-1_9228655a4359b614255e2c4a3124d0e3 |
---|---|
oai_identifier_str |
oai:scielo:S1983-41952018000501110 |
network_acronym_str |
IBRACON-1 |
network_name_str |
Revista IBRACON de Estruturas e Materiais |
repository_id_str |
|
spelling |
Punching shear in concrete reinforced flat slabs with steel fibers and shear reinforcementreinforced concreteflat slabspunchingshearfibersAbstract Steel fibers in reinforced concrete increase the performance of slab-column connection once they increase ductility and energy absorption capacity of the concrete. The use of fibers in flat slabs may increase strength and change the mode of failure. The objective of this work is to present an experimental evaluation of punching shear strength of reinforced concrete flat slab with steel fibers and punching shear reinforcement. Eight square slabs, size 1800 mm by 1800 mm by 130mm, were loaded until failure by punching shear around the column. The models were divided in two groups, depending on the type of the concrete used (with or without steel fibers). The steel fiber volume used in the slabs of second group was of 0.9%. Each group was composed of four slabs: one without shear reinforcement and three with shear reinforcement (studs) distributed radially around the column. The use of steel fibers increased the ultimate strength of all flat slabs. In one of the slabs, the association of steel fibers with shear reinforcement changed the failure surface from outside to inside the punching shear reinforcement region.IBRACON - Instituto Brasileiro do Concreto2018-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952018000501110Revista IBRACON de Estruturas e Materiais v.11 n.5 2018reponame:Revista IBRACON de Estruturas e Materiaisinstname:Instituto Brasileiro do Concreto (IBRACON)instacron:IBRACON10.1590/s1983-41952018000500011info:eu-repo/semantics/openAccessMUSSE,T. H.LIBERATI,E. A. P.TRAUTWEIN,L. M.GOMES,R. B.GUIMARÃES,G. N.eng2018-10-16T00:00:00Zoai:scielo:S1983-41952018000501110Revistahttp://www.revistas.ibracon.org.br/index.php/riemhttps://old.scielo.br/oai/scielo-oai.phpeditores.riem@gmail.com||arlene@ibracon.org.br1983-41951983-4195opendoar:2018-10-16T00:00Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)false |
dc.title.none.fl_str_mv |
Punching shear in concrete reinforced flat slabs with steel fibers and shear reinforcement |
title |
Punching shear in concrete reinforced flat slabs with steel fibers and shear reinforcement |
spellingShingle |
Punching shear in concrete reinforced flat slabs with steel fibers and shear reinforcement MUSSE,T. H. reinforced concrete flat slabs punching shear fibers |
title_short |
Punching shear in concrete reinforced flat slabs with steel fibers and shear reinforcement |
title_full |
Punching shear in concrete reinforced flat slabs with steel fibers and shear reinforcement |
title_fullStr |
Punching shear in concrete reinforced flat slabs with steel fibers and shear reinforcement |
title_full_unstemmed |
Punching shear in concrete reinforced flat slabs with steel fibers and shear reinforcement |
title_sort |
Punching shear in concrete reinforced flat slabs with steel fibers and shear reinforcement |
author |
MUSSE,T. H. |
author_facet |
MUSSE,T. H. LIBERATI,E. A. P. TRAUTWEIN,L. M. GOMES,R. B. GUIMARÃES,G. N. |
author_role |
author |
author2 |
LIBERATI,E. A. P. TRAUTWEIN,L. M. GOMES,R. B. GUIMARÃES,G. N. |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
MUSSE,T. H. LIBERATI,E. A. P. TRAUTWEIN,L. M. GOMES,R. B. GUIMARÃES,G. N. |
dc.subject.por.fl_str_mv |
reinforced concrete flat slabs punching shear fibers |
topic |
reinforced concrete flat slabs punching shear fibers |
description |
Abstract Steel fibers in reinforced concrete increase the performance of slab-column connection once they increase ductility and energy absorption capacity of the concrete. The use of fibers in flat slabs may increase strength and change the mode of failure. The objective of this work is to present an experimental evaluation of punching shear strength of reinforced concrete flat slab with steel fibers and punching shear reinforcement. Eight square slabs, size 1800 mm by 1800 mm by 130mm, were loaded until failure by punching shear around the column. The models were divided in two groups, depending on the type of the concrete used (with or without steel fibers). The steel fiber volume used in the slabs of second group was of 0.9%. Each group was composed of four slabs: one without shear reinforcement and three with shear reinforcement (studs) distributed radially around the column. The use of steel fibers increased the ultimate strength of all flat slabs. In one of the slabs, the association of steel fibers with shear reinforcement changed the failure surface from outside to inside the punching shear reinforcement region. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952018000501110 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952018000501110 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/s1983-41952018000500011 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
IBRACON - Instituto Brasileiro do Concreto |
publisher.none.fl_str_mv |
IBRACON - Instituto Brasileiro do Concreto |
dc.source.none.fl_str_mv |
Revista IBRACON de Estruturas e Materiais v.11 n.5 2018 reponame:Revista IBRACON de Estruturas e Materiais instname:Instituto Brasileiro do Concreto (IBRACON) instacron:IBRACON |
instname_str |
Instituto Brasileiro do Concreto (IBRACON) |
instacron_str |
IBRACON |
institution |
IBRACON |
reponame_str |
Revista IBRACON de Estruturas e Materiais |
collection |
Revista IBRACON de Estruturas e Materiais |
repository.name.fl_str_mv |
Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON) |
repository.mail.fl_str_mv |
editores.riem@gmail.com||arlene@ibracon.org.br |
_version_ |
1754193605580292096 |