The users centered design of a new digital fluorometer
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo de conferência |
Idioma: | eng |
Título da fonte: | Repositório Institucional do IEN |
Texto Completo: | http://carpedien.ien.gov.br:8080/handle/ien/2542 |
Resumo: | The fluorometer is an equipment used in chemical analysis laboratories, research institutes and nuclear fuel cycle companies. This equipment measures an unknown amount of uranium in ores, rivers, etc. The fluorometer functioning is based on the uranium fluorescence when submitted to the ultraviolet radiation incidence. The fluorescence is measured by an electronic optic system with optics filters, photomultiplier tube, and a current amplifier. The user centered design involvers the user in the product development in all phases of the design process. Users are not simply consulted at the beginning of the design process and evaluated the system at the end; they are treated as partners throughout the design process. The user centered design emphasizes the needs and abilities of the users and improves the usability of the equipment. The activity centered design emphasizes the development of the equipment with a deep understanding of the users activities and of the current work practices of the users. The aim of this paper is to present a methodological framework that contributes to the design and evaluation of a new digital fluorometer towards an approach related to the users and their activities. This methodological framework includes users-based testing, interviews, questionnaires, human factors standards and guidelines, the users activity analysis and users satisfaction questionnaire. |
id |
IEN_814481ee917fa6bb3b27104714da3fc5 |
---|---|
oai_identifier_str |
oai:carpedien.ien.gov.br:ien/2542 |
network_acronym_str |
IEN |
network_name_str |
Repositório Institucional do IEN |
spelling |
Farias, Marcos SantanaSantos, Isaac José Antônio Luquetti dosGomes, Luciene Betzler CardosoColthrust, Carlos MC DonaldSzabó, AndreSousa, Alvaro Serafim Ferreira deInstituto de Engenharia Nuclear2018-07-13T13:45:22Z2018-07-13T13:45:22Z2007-09http://carpedien.ien.gov.br:8080/handle/ien/2542Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2018-07-13T13:45:22Z No. of bitstreams: 1 THE USERS CENTERED DESIGN OF A NEW DIGITAL FLUOROMETER.pdf: 169939 bytes, checksum: 3ff791a5af5f7f62610e32457d92ef21 (MD5)Made available in DSpace on 2018-07-13T13:45:22Z (GMT). No. of bitstreams: 1 THE USERS CENTERED DESIGN OF A NEW DIGITAL FLUOROMETER.pdf: 169939 bytes, checksum: 3ff791a5af5f7f62610e32457d92ef21 (MD5) Previous issue date: 2007-09The fluorometer is an equipment used in chemical analysis laboratories, research institutes and nuclear fuel cycle companies. This equipment measures an unknown amount of uranium in ores, rivers, etc. The fluorometer functioning is based on the uranium fluorescence when submitted to the ultraviolet radiation incidence. The fluorescence is measured by an electronic optic system with optics filters, photomultiplier tube, and a current amplifier. The user centered design involvers the user in the product development in all phases of the design process. Users are not simply consulted at the beginning of the design process and evaluated the system at the end; they are treated as partners throughout the design process. The user centered design emphasizes the needs and abilities of the users and improves the usability of the equipment. The activity centered design emphasizes the development of the equipment with a deep understanding of the users activities and of the current work practices of the users. The aim of this paper is to present a methodological framework that contributes to the design and evaluation of a new digital fluorometer towards an approach related to the users and their activities. This methodological framework includes users-based testing, interviews, questionnaires, human factors standards and guidelines, the users activity analysis and users satisfaction questionnaire.engInstituto de Engenharia NuclearIENBrasilINAC 2007Digital FluometerEquipment usabilityThe users centered design of a new digital fluorometerinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObjectIII INACinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional do IENinstname:Instituto de Engenharia Nuclearinstacron:IENLICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/2542/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52ORIGINALTHE USERS CENTERED DESIGN OF A NEW DIGITAL FLUOROMETER.pdfTHE USERS CENTERED DESIGN OF A NEW DIGITAL FLUOROMETER.pdfapplication/pdf169939http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/2542/1/THE+USERS+CENTERED+DESIGN+OF+A+NEW+DIGITAL+FLUOROMETER.pdf3ff791a5af5f7f62610e32457d92ef21MD51ien/2542oai:carpedien.ien.gov.br:ien/25422018-07-13 10:45:22.186Dspace IENlsales@ien.gov.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 |
dc.title.pt_BR.fl_str_mv |
The users centered design of a new digital fluorometer |
title |
The users centered design of a new digital fluorometer |
spellingShingle |
The users centered design of a new digital fluorometer Farias, Marcos Santana INAC 2007 Digital Fluometer Equipment usability |
title_short |
The users centered design of a new digital fluorometer |
title_full |
The users centered design of a new digital fluorometer |
title_fullStr |
The users centered design of a new digital fluorometer |
title_full_unstemmed |
The users centered design of a new digital fluorometer |
title_sort |
The users centered design of a new digital fluorometer |
author |
Farias, Marcos Santana |
author_facet |
Farias, Marcos Santana Santos, Isaac José Antônio Luquetti dos Gomes, Luciene Betzler Cardoso Colthrust, Carlos MC Donald Szabó, Andre Sousa, Alvaro Serafim Ferreira de Instituto de Engenharia Nuclear |
author_role |
author |
author2 |
Santos, Isaac José Antônio Luquetti dos Gomes, Luciene Betzler Cardoso Colthrust, Carlos MC Donald Szabó, Andre Sousa, Alvaro Serafim Ferreira de Instituto de Engenharia Nuclear |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Farias, Marcos Santana Santos, Isaac José Antônio Luquetti dos Gomes, Luciene Betzler Cardoso Colthrust, Carlos MC Donald Szabó, Andre Sousa, Alvaro Serafim Ferreira de Instituto de Engenharia Nuclear |
dc.subject.por.fl_str_mv |
INAC 2007 Digital Fluometer Equipment usability |
topic |
INAC 2007 Digital Fluometer Equipment usability |
dc.description.abstract.por.fl_txt_mv |
The fluorometer is an equipment used in chemical analysis laboratories, research institutes and nuclear fuel cycle companies. This equipment measures an unknown amount of uranium in ores, rivers, etc. The fluorometer functioning is based on the uranium fluorescence when submitted to the ultraviolet radiation incidence. The fluorescence is measured by an electronic optic system with optics filters, photomultiplier tube, and a current amplifier. The user centered design involvers the user in the product development in all phases of the design process. Users are not simply consulted at the beginning of the design process and evaluated the system at the end; they are treated as partners throughout the design process. The user centered design emphasizes the needs and abilities of the users and improves the usability of the equipment. The activity centered design emphasizes the development of the equipment with a deep understanding of the users activities and of the current work practices of the users. The aim of this paper is to present a methodological framework that contributes to the design and evaluation of a new digital fluorometer towards an approach related to the users and their activities. This methodological framework includes users-based testing, interviews, questionnaires, human factors standards and guidelines, the users activity analysis and users satisfaction questionnaire. |
description |
The fluorometer is an equipment used in chemical analysis laboratories, research institutes and nuclear fuel cycle companies. This equipment measures an unknown amount of uranium in ores, rivers, etc. The fluorometer functioning is based on the uranium fluorescence when submitted to the ultraviolet radiation incidence. The fluorescence is measured by an electronic optic system with optics filters, photomultiplier tube, and a current amplifier. The user centered design involvers the user in the product development in all phases of the design process. Users are not simply consulted at the beginning of the design process and evaluated the system at the end; they are treated as partners throughout the design process. The user centered design emphasizes the needs and abilities of the users and improves the usability of the equipment. The activity centered design emphasizes the development of the equipment with a deep understanding of the users activities and of the current work practices of the users. The aim of this paper is to present a methodological framework that contributes to the design and evaluation of a new digital fluorometer towards an approach related to the users and their activities. This methodological framework includes users-based testing, interviews, questionnaires, human factors standards and guidelines, the users activity analysis and users satisfaction questionnaire. |
publishDate |
2007 |
dc.date.issued.fl_str_mv |
2007-09 |
dc.date.accessioned.fl_str_mv |
2018-07-13T13:45:22Z |
dc.date.available.fl_str_mv |
2018-07-13T13:45:22Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
status_str |
publishedVersion |
format |
conferenceObject |
dc.identifier.uri.fl_str_mv |
http://carpedien.ien.gov.br:8080/handle/ien/2542 |
url |
http://carpedien.ien.gov.br:8080/handle/ien/2542 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Instituto de Engenharia Nuclear |
dc.publisher.initials.fl_str_mv |
IEN |
dc.publisher.country.fl_str_mv |
Brasil |
publisher.none.fl_str_mv |
Instituto de Engenharia Nuclear |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional do IEN instname:Instituto de Engenharia Nuclear instacron:IEN |
reponame_str |
Repositório Institucional do IEN |
collection |
Repositório Institucional do IEN |
instname_str |
Instituto de Engenharia Nuclear |
instacron_str |
IEN |
institution |
IEN |
bitstream.url.fl_str_mv |
http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/2542/2/license.txt http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/2542/1/THE+USERS+CENTERED+DESIGN+OF+A+NEW+DIGITAL+FLUOROMETER.pdf |
bitstream.checksum.fl_str_mv |
8a4605be74aa9ea9d79846c1fba20a33 3ff791a5af5f7f62610e32457d92ef21 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Dspace IEN |
repository.mail.fl_str_mv |
lsales@ien.gov.br |
_version_ |
1656026995447824384 |