Prostate volume measurement by multiparametric magnetic resonance and transrectal ultrasound: comparison with surgical specimen weight

Detalhes bibliográficos
Autor(a) principal: Martins,Tatiana
Data de Publicação: 2020
Outros Autores: Mussi,Thais Caldara, Baroni,Ronaldo Hueb
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Einstein (São Paulo)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082020000100235
Resumo: ABSTRACT Objective To assess accuracy of multiparametric magnetic resonance of the prostate to estimate gland volume, comparing the results with transrectal ultrasound and surgical specimen. Methods A retrospective study of 85 patients who underwent multiparametric magnetic resonance and transrectal ultrasound (for fusion image-guided biopsy) before radical prostatectomy. Prostate measurements were obtained from magnetic resonance axial and sagittal T2-weighted images and ultrasound; the prostate volume was determined using the ellipsoid formula. The results were compared with the surgical specimen weight. Maximum interval between multiparametric magnetic resonance imaging, transrectal ultrasound, and prostatectomy was 6 months. Results The prostate volume measured by multiparametric magnetic resonance imaging was 18-157cm3 (mean of 49.9cm3) and by transrectal ultrasound, 22-165cm3 (mean of 54.9cm3); the surgical specimen weight was 20-154g (mean of 48.6g), with no statistical differences. Based on the values obtained from imaging examinations, the prostate volume obtained was very close to the real prostatic weight, and the measures by multiparametric magnetic resonance were slightly more precise. Conclusion Prostate volume measured by multiparametric magnetic resonance imaging and transrectal ultrasound showed similar values, and excellent agreement with real prostate weight of the surgical specimens. Prostate volume measured by magnetic resonance has been increasingly used in the clinical practice, and its value enables appropriate therapeutic planning and control of patients.
id IIEPAE-1_4f87b075aee7de80599bf390ce933b4b
oai_identifier_str oai:scielo:S1679-45082020000100235
network_acronym_str IIEPAE-1
network_name_str Einstein (São Paulo)
repository_id_str
spelling Prostate volume measurement by multiparametric magnetic resonance and transrectal ultrasound: comparison with surgical specimen weightProstatectomyMagnetic resonance imagingMagnetic resonance spectroscopyUltrasonographyProstatic diseasesABSTRACT Objective To assess accuracy of multiparametric magnetic resonance of the prostate to estimate gland volume, comparing the results with transrectal ultrasound and surgical specimen. Methods A retrospective study of 85 patients who underwent multiparametric magnetic resonance and transrectal ultrasound (for fusion image-guided biopsy) before radical prostatectomy. Prostate measurements were obtained from magnetic resonance axial and sagittal T2-weighted images and ultrasound; the prostate volume was determined using the ellipsoid formula. The results were compared with the surgical specimen weight. Maximum interval between multiparametric magnetic resonance imaging, transrectal ultrasound, and prostatectomy was 6 months. Results The prostate volume measured by multiparametric magnetic resonance imaging was 18-157cm3 (mean of 49.9cm3) and by transrectal ultrasound, 22-165cm3 (mean of 54.9cm3); the surgical specimen weight was 20-154g (mean of 48.6g), with no statistical differences. Based on the values obtained from imaging examinations, the prostate volume obtained was very close to the real prostatic weight, and the measures by multiparametric magnetic resonance were slightly more precise. Conclusion Prostate volume measured by multiparametric magnetic resonance imaging and transrectal ultrasound showed similar values, and excellent agreement with real prostate weight of the surgical specimens. Prostate volume measured by magnetic resonance has been increasingly used in the clinical practice, and its value enables appropriate therapeutic planning and control of patients.Instituto Israelita de Ensino e Pesquisa Albert Einstein2020-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082020000100235einstein (São Paulo) v.18 2020reponame:Einstein (São Paulo)instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)instacron:IIEPAE10.31744/einstein_journal/2020ao4662info:eu-repo/semantics/openAccessMartins,TatianaMussi,Thais CaldaraBaroni,Ronaldo Huebeng2020-01-28T00:00:00Zoai:scielo:S1679-45082020000100235Revistahttps://journal.einstein.br/pt-br/ONGhttps://old.scielo.br/oai/scielo-oai.php||revista@einstein.br2317-63851679-4508opendoar:2020-01-28T00:00Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)false
dc.title.none.fl_str_mv Prostate volume measurement by multiparametric magnetic resonance and transrectal ultrasound: comparison with surgical specimen weight
title Prostate volume measurement by multiparametric magnetic resonance and transrectal ultrasound: comparison with surgical specimen weight
spellingShingle Prostate volume measurement by multiparametric magnetic resonance and transrectal ultrasound: comparison with surgical specimen weight
Martins,Tatiana
Prostatectomy
Magnetic resonance imaging
Magnetic resonance spectroscopy
Ultrasonography
Prostatic diseases
title_short Prostate volume measurement by multiparametric magnetic resonance and transrectal ultrasound: comparison with surgical specimen weight
title_full Prostate volume measurement by multiparametric magnetic resonance and transrectal ultrasound: comparison with surgical specimen weight
title_fullStr Prostate volume measurement by multiparametric magnetic resonance and transrectal ultrasound: comparison with surgical specimen weight
title_full_unstemmed Prostate volume measurement by multiparametric magnetic resonance and transrectal ultrasound: comparison with surgical specimen weight
title_sort Prostate volume measurement by multiparametric magnetic resonance and transrectal ultrasound: comparison with surgical specimen weight
author Martins,Tatiana
author_facet Martins,Tatiana
Mussi,Thais Caldara
Baroni,Ronaldo Hueb
author_role author
author2 Mussi,Thais Caldara
Baroni,Ronaldo Hueb
author2_role author
author
dc.contributor.author.fl_str_mv Martins,Tatiana
Mussi,Thais Caldara
Baroni,Ronaldo Hueb
dc.subject.por.fl_str_mv Prostatectomy
Magnetic resonance imaging
Magnetic resonance spectroscopy
Ultrasonography
Prostatic diseases
topic Prostatectomy
Magnetic resonance imaging
Magnetic resonance spectroscopy
Ultrasonography
Prostatic diseases
description ABSTRACT Objective To assess accuracy of multiparametric magnetic resonance of the prostate to estimate gland volume, comparing the results with transrectal ultrasound and surgical specimen. Methods A retrospective study of 85 patients who underwent multiparametric magnetic resonance and transrectal ultrasound (for fusion image-guided biopsy) before radical prostatectomy. Prostate measurements were obtained from magnetic resonance axial and sagittal T2-weighted images and ultrasound; the prostate volume was determined using the ellipsoid formula. The results were compared with the surgical specimen weight. Maximum interval between multiparametric magnetic resonance imaging, transrectal ultrasound, and prostatectomy was 6 months. Results The prostate volume measured by multiparametric magnetic resonance imaging was 18-157cm3 (mean of 49.9cm3) and by transrectal ultrasound, 22-165cm3 (mean of 54.9cm3); the surgical specimen weight was 20-154g (mean of 48.6g), with no statistical differences. Based on the values obtained from imaging examinations, the prostate volume obtained was very close to the real prostatic weight, and the measures by multiparametric magnetic resonance were slightly more precise. Conclusion Prostate volume measured by multiparametric magnetic resonance imaging and transrectal ultrasound showed similar values, and excellent agreement with real prostate weight of the surgical specimens. Prostate volume measured by magnetic resonance has been increasingly used in the clinical practice, and its value enables appropriate therapeutic planning and control of patients.
publishDate 2020
dc.date.none.fl_str_mv 2020-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082020000100235
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082020000100235
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.31744/einstein_journal/2020ao4662
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto Israelita de Ensino e Pesquisa Albert Einstein
publisher.none.fl_str_mv Instituto Israelita de Ensino e Pesquisa Albert Einstein
dc.source.none.fl_str_mv einstein (São Paulo) v.18 2020
reponame:Einstein (São Paulo)
instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
instacron:IIEPAE
instname_str Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
instacron_str IIEPAE
institution IIEPAE
reponame_str Einstein (São Paulo)
collection Einstein (São Paulo)
repository.name.fl_str_mv Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
repository.mail.fl_str_mv ||revista@einstein.br
_version_ 1752129910063759360