Accuracy of echocardiography and chest tomography for pulmonary hypertension screening in patients awaiting lung transplantation

Detalhes bibliográficos
Autor(a) principal: Degani-Costa,Luiza Helena
Data de Publicação: 2021
Outros Autores: Assis,João Paulo de, Gonçalves,Pedro Paulo Pisaniello, Gushken,Fernanda, Szarf,Gilberto, Afonso Junior,José Eduardo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Einstein (São Paulo)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082021000100256
Resumo: ABSTRACT Objective To examine the accuracy of a pulmonary hypertension screening strategy based on a combination of echocardiographic data and tomographic measurements (pulmonary artery diameter and pulmonary artery diameter to ascending aorta diameter ratio) in patients with chronic lung disease referred for lung transplantation. Methods A retrospective observational study with patients with pulmonary emphysema or fibrosis referred for transplantation between 2012 and 2016. Pulmonary hypertension was defined as mean pulmonary artery pressure ≥25mmHg, or between 21 and 24mmHg, with pulmonary vascular resistance >3 Wood units on right heart catheterization. Tomographic measurements were made by two independent radiologists. Results This sample comprised 13 patients with emphysema and 19 patients with pulmonary fibrosis. Of these, 18 had pulmonary hypertension. The level of agreement in tomographic measurements made by radiologists was high (intraclass correlation coefficients 0.936 and 0.940, for pulmonary artery diameter and pulmonary artery diameter to ascending aorta diameter ratio, respectively). Areas under the ROC curves constructed for pulmonary artery diameter, pulmonary artery diameter to ascending aorta diameter ratio, and pulmonary artery systolic pressure as predictors of pulmonary hypertension were 0.540, 0.629 and 0.783, respectively. The sensitivity, specificity and negative predictive value of pulmonary artery systolic pressure ≥40mmHg were 67%, 79% and 65%, respectively. The combined criterion (pulmonary artery diameter to ascending aorta diameter ratio >1 and/or pulmonary artery systolic pressure ≥40mmHg) achieved sensitivity of 72%, specificity of 79%, and a negative predictive value of 69%. Conclusion Measurements of pulmonary artery and ascending aorta diameter were highly reproducible. The association of pulmonary artery and aortic diameter >1 and/or pulmonary artery systolic pressure ≥40mmHg improved the sensitivity and the negative predictive value for pulmonary hypertension screening. This strategy demands prospective validation to assess safety and cost-effectiveness.
id IIEPAE-1_6c51658d3cb8ca6f4b31e89c0540b04d
oai_identifier_str oai:scielo:S1679-45082021000100256
network_acronym_str IIEPAE-1
network_name_str Einstein (São Paulo)
repository_id_str
spelling Accuracy of echocardiography and chest tomography for pulmonary hypertension screening in patients awaiting lung transplantationHypertension, pulmonaryTransplantationEchocardiographyTomography, x-ray computedThorax/diagnostic imagingCardiac catheterizationABSTRACT Objective To examine the accuracy of a pulmonary hypertension screening strategy based on a combination of echocardiographic data and tomographic measurements (pulmonary artery diameter and pulmonary artery diameter to ascending aorta diameter ratio) in patients with chronic lung disease referred for lung transplantation. Methods A retrospective observational study with patients with pulmonary emphysema or fibrosis referred for transplantation between 2012 and 2016. Pulmonary hypertension was defined as mean pulmonary artery pressure ≥25mmHg, or between 21 and 24mmHg, with pulmonary vascular resistance >3 Wood units on right heart catheterization. Tomographic measurements were made by two independent radiologists. Results This sample comprised 13 patients with emphysema and 19 patients with pulmonary fibrosis. Of these, 18 had pulmonary hypertension. The level of agreement in tomographic measurements made by radiologists was high (intraclass correlation coefficients 0.936 and 0.940, for pulmonary artery diameter and pulmonary artery diameter to ascending aorta diameter ratio, respectively). Areas under the ROC curves constructed for pulmonary artery diameter, pulmonary artery diameter to ascending aorta diameter ratio, and pulmonary artery systolic pressure as predictors of pulmonary hypertension were 0.540, 0.629 and 0.783, respectively. The sensitivity, specificity and negative predictive value of pulmonary artery systolic pressure ≥40mmHg were 67%, 79% and 65%, respectively. The combined criterion (pulmonary artery diameter to ascending aorta diameter ratio >1 and/or pulmonary artery systolic pressure ≥40mmHg) achieved sensitivity of 72%, specificity of 79%, and a negative predictive value of 69%. Conclusion Measurements of pulmonary artery and ascending aorta diameter were highly reproducible. The association of pulmonary artery and aortic diameter >1 and/or pulmonary artery systolic pressure ≥40mmHg improved the sensitivity and the negative predictive value for pulmonary hypertension screening. This strategy demands prospective validation to assess safety and cost-effectiveness.Instituto Israelita de Ensino e Pesquisa Albert Einstein2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082021000100256einstein (São Paulo) v.19 2021reponame:Einstein (São Paulo)instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)instacron:IIEPAE10.31744/einstein_journal/2021ao5710info:eu-repo/semantics/openAccessDegani-Costa,Luiza HelenaAssis,João Paulo deGonçalves,Pedro Paulo PisanielloGushken,FernandaSzarf,GilbertoAfonso Junior,José Eduardoeng2021-12-17T00:00:00Zoai:scielo:S1679-45082021000100256Revistahttps://journal.einstein.br/pt-br/ONGhttps://old.scielo.br/oai/scielo-oai.php||revista@einstein.br2317-63851679-4508opendoar:2021-12-17T00:00Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)false
dc.title.none.fl_str_mv Accuracy of echocardiography and chest tomography for pulmonary hypertension screening in patients awaiting lung transplantation
title Accuracy of echocardiography and chest tomography for pulmonary hypertension screening in patients awaiting lung transplantation
spellingShingle Accuracy of echocardiography and chest tomography for pulmonary hypertension screening in patients awaiting lung transplantation
Degani-Costa,Luiza Helena
Hypertension, pulmonary
Transplantation
Echocardiography
Tomography, x-ray computed
Thorax/diagnostic imaging
Cardiac catheterization
title_short Accuracy of echocardiography and chest tomography for pulmonary hypertension screening in patients awaiting lung transplantation
title_full Accuracy of echocardiography and chest tomography for pulmonary hypertension screening in patients awaiting lung transplantation
title_fullStr Accuracy of echocardiography and chest tomography for pulmonary hypertension screening in patients awaiting lung transplantation
title_full_unstemmed Accuracy of echocardiography and chest tomography for pulmonary hypertension screening in patients awaiting lung transplantation
title_sort Accuracy of echocardiography and chest tomography for pulmonary hypertension screening in patients awaiting lung transplantation
author Degani-Costa,Luiza Helena
author_facet Degani-Costa,Luiza Helena
Assis,João Paulo de
Gonçalves,Pedro Paulo Pisaniello
Gushken,Fernanda
Szarf,Gilberto
Afonso Junior,José Eduardo
author_role author
author2 Assis,João Paulo de
Gonçalves,Pedro Paulo Pisaniello
Gushken,Fernanda
Szarf,Gilberto
Afonso Junior,José Eduardo
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Degani-Costa,Luiza Helena
Assis,João Paulo de
Gonçalves,Pedro Paulo Pisaniello
Gushken,Fernanda
Szarf,Gilberto
Afonso Junior,José Eduardo
dc.subject.por.fl_str_mv Hypertension, pulmonary
Transplantation
Echocardiography
Tomography, x-ray computed
Thorax/diagnostic imaging
Cardiac catheterization
topic Hypertension, pulmonary
Transplantation
Echocardiography
Tomography, x-ray computed
Thorax/diagnostic imaging
Cardiac catheterization
description ABSTRACT Objective To examine the accuracy of a pulmonary hypertension screening strategy based on a combination of echocardiographic data and tomographic measurements (pulmonary artery diameter and pulmonary artery diameter to ascending aorta diameter ratio) in patients with chronic lung disease referred for lung transplantation. Methods A retrospective observational study with patients with pulmonary emphysema or fibrosis referred for transplantation between 2012 and 2016. Pulmonary hypertension was defined as mean pulmonary artery pressure ≥25mmHg, or between 21 and 24mmHg, with pulmonary vascular resistance >3 Wood units on right heart catheterization. Tomographic measurements were made by two independent radiologists. Results This sample comprised 13 patients with emphysema and 19 patients with pulmonary fibrosis. Of these, 18 had pulmonary hypertension. The level of agreement in tomographic measurements made by radiologists was high (intraclass correlation coefficients 0.936 and 0.940, for pulmonary artery diameter and pulmonary artery diameter to ascending aorta diameter ratio, respectively). Areas under the ROC curves constructed for pulmonary artery diameter, pulmonary artery diameter to ascending aorta diameter ratio, and pulmonary artery systolic pressure as predictors of pulmonary hypertension were 0.540, 0.629 and 0.783, respectively. The sensitivity, specificity and negative predictive value of pulmonary artery systolic pressure ≥40mmHg were 67%, 79% and 65%, respectively. The combined criterion (pulmonary artery diameter to ascending aorta diameter ratio >1 and/or pulmonary artery systolic pressure ≥40mmHg) achieved sensitivity of 72%, specificity of 79%, and a negative predictive value of 69%. Conclusion Measurements of pulmonary artery and ascending aorta diameter were highly reproducible. The association of pulmonary artery and aortic diameter >1 and/or pulmonary artery systolic pressure ≥40mmHg improved the sensitivity and the negative predictive value for pulmonary hypertension screening. This strategy demands prospective validation to assess safety and cost-effectiveness.
publishDate 2021
dc.date.none.fl_str_mv 2021-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082021000100256
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082021000100256
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.31744/einstein_journal/2021ao5710
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto Israelita de Ensino e Pesquisa Albert Einstein
publisher.none.fl_str_mv Instituto Israelita de Ensino e Pesquisa Albert Einstein
dc.source.none.fl_str_mv einstein (São Paulo) v.19 2021
reponame:Einstein (São Paulo)
instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
instacron:IIEPAE
instname_str Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
instacron_str IIEPAE
institution IIEPAE
reponame_str Einstein (São Paulo)
collection Einstein (São Paulo)
repository.name.fl_str_mv Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
repository.mail.fl_str_mv ||revista@einstein.br
_version_ 1752129910633136128