Resumo: | ABSTRACT Objective To evaluate the ability of blood-oxygen-level-dependent (BOLD) magnetic resonance imaging at 3 Tesla to measure tissue oxygen bioavailability based on R2* values, and to differentiate between acute tubular necrosis and acute rejection compared to renal biopsy (gold standard). Methods A prospective, single-center study, with patients submitted to renal transplantation between 2013 and 2014, who developed graft dysfunction less than 4 weeks after transplantation. All patients were submitted to abdominal magnetic resonance imaging at 3 Tesla using the same protocol, followed by two BOLD sequences and kidney biopsy. Results Twelve male (68.75%) and three female (31.25%) patients were included. A total of 19 percutaneous renal biopsies were performed (four patients required a second biopsy due to changes in clinical findings). Pathological findings revealed ten cases of acute tubular necrosis, four cases of acute rejection, and five cases with other (miscellaneous) diagnoses. Comparison between the four groups of interest failed to reveal significant differences (p=0.177) in cortical R2* values, whereas medullary R2* values differed significantly (p=0.033), with lower values in the miscellaneous diagnoses and the acute tubular necrosis group. Conclusion BOLD magnetic resonance imaging at 3 Tesla is a feasible technique that uses indirect tissue oxygen level measurements to differentiate between acute rejection and acute tubular necrosis in renal grafts. |
id |
IIEPAE-1_c0e5adf17173211527098fa8b7e77bdb |
---|---|
oai_identifier_str |
oai:scielo:S1679-45082021000100225 |
network_acronym_str |
IIEPAE-1 |
network_name_str |
Einstein (São Paulo) |
repository_id_str |
|
spelling |
Evaluation of the blood-oxygen-level-dependent (BOLD) sequence with 3 Tesla device in renal transplant patients in the assessment of early allograft disfunction, correlated with biopsyMagnetic resonance imagingKidney transplantationBiopsyPrimary graft dysfunctionABSTRACT Objective To evaluate the ability of blood-oxygen-level-dependent (BOLD) magnetic resonance imaging at 3 Tesla to measure tissue oxygen bioavailability based on R2* values, and to differentiate between acute tubular necrosis and acute rejection compared to renal biopsy (gold standard). Methods A prospective, single-center study, with patients submitted to renal transplantation between 2013 and 2014, who developed graft dysfunction less than 4 weeks after transplantation. All patients were submitted to abdominal magnetic resonance imaging at 3 Tesla using the same protocol, followed by two BOLD sequences and kidney biopsy. Results Twelve male (68.75%) and three female (31.25%) patients were included. A total of 19 percutaneous renal biopsies were performed (four patients required a second biopsy due to changes in clinical findings). Pathological findings revealed ten cases of acute tubular necrosis, four cases of acute rejection, and five cases with other (miscellaneous) diagnoses. Comparison between the four groups of interest failed to reveal significant differences (p=0.177) in cortical R2* values, whereas medullary R2* values differed significantly (p=0.033), with lower values in the miscellaneous diagnoses and the acute tubular necrosis group. Conclusion BOLD magnetic resonance imaging at 3 Tesla is a feasible technique that uses indirect tissue oxygen level measurements to differentiate between acute rejection and acute tubular necrosis in renal grafts.Instituto Israelita de Ensino e Pesquisa Albert Einstein2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082021000100225einstein (São Paulo) v.19 2021reponame:Einstein (São Paulo)instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)instacron:IIEPAE10.31744/einstein_journal/2021ao6069info:eu-repo/semantics/openAccessMendes,Guilherme FalleirosFalsarella,Priscila MinaGarcia,Rodrigo GobboSanches,Liana GuerraBaroni,Ronaldo Huebeng2021-08-18T00:00:00Zoai:scielo:S1679-45082021000100225Revistahttps://journal.einstein.br/pt-br/ONGhttps://old.scielo.br/oai/scielo-oai.php||revista@einstein.br2317-63851679-4508opendoar:2021-08-18T00:00Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)false |
dc.title.none.fl_str_mv |
Evaluation of the blood-oxygen-level-dependent (BOLD) sequence with 3 Tesla device in renal transplant patients in the assessment of early allograft disfunction, correlated with biopsy |
title |
Evaluation of the blood-oxygen-level-dependent (BOLD) sequence with 3 Tesla device in renal transplant patients in the assessment of early allograft disfunction, correlated with biopsy |
spellingShingle |
Evaluation of the blood-oxygen-level-dependent (BOLD) sequence with 3 Tesla device in renal transplant patients in the assessment of early allograft disfunction, correlated with biopsy Mendes,Guilherme Falleiros Magnetic resonance imaging Kidney transplantation Biopsy Primary graft dysfunction |
title_short |
Evaluation of the blood-oxygen-level-dependent (BOLD) sequence with 3 Tesla device in renal transplant patients in the assessment of early allograft disfunction, correlated with biopsy |
title_full |
Evaluation of the blood-oxygen-level-dependent (BOLD) sequence with 3 Tesla device in renal transplant patients in the assessment of early allograft disfunction, correlated with biopsy |
title_fullStr |
Evaluation of the blood-oxygen-level-dependent (BOLD) sequence with 3 Tesla device in renal transplant patients in the assessment of early allograft disfunction, correlated with biopsy |
title_full_unstemmed |
Evaluation of the blood-oxygen-level-dependent (BOLD) sequence with 3 Tesla device in renal transplant patients in the assessment of early allograft disfunction, correlated with biopsy |
title_sort |
Evaluation of the blood-oxygen-level-dependent (BOLD) sequence with 3 Tesla device in renal transplant patients in the assessment of early allograft disfunction, correlated with biopsy |
author |
Mendes,Guilherme Falleiros |
author_facet |
Mendes,Guilherme Falleiros Falsarella,Priscila Mina Garcia,Rodrigo Gobbo Sanches,Liana Guerra Baroni,Ronaldo Hueb |
author_role |
author |
author2 |
Falsarella,Priscila Mina Garcia,Rodrigo Gobbo Sanches,Liana Guerra Baroni,Ronaldo Hueb |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Mendes,Guilherme Falleiros Falsarella,Priscila Mina Garcia,Rodrigo Gobbo Sanches,Liana Guerra Baroni,Ronaldo Hueb |
dc.subject.por.fl_str_mv |
Magnetic resonance imaging Kidney transplantation Biopsy Primary graft dysfunction |
topic |
Magnetic resonance imaging Kidney transplantation Biopsy Primary graft dysfunction |
description |
ABSTRACT Objective To evaluate the ability of blood-oxygen-level-dependent (BOLD) magnetic resonance imaging at 3 Tesla to measure tissue oxygen bioavailability based on R2* values, and to differentiate between acute tubular necrosis and acute rejection compared to renal biopsy (gold standard). Methods A prospective, single-center study, with patients submitted to renal transplantation between 2013 and 2014, who developed graft dysfunction less than 4 weeks after transplantation. All patients were submitted to abdominal magnetic resonance imaging at 3 Tesla using the same protocol, followed by two BOLD sequences and kidney biopsy. Results Twelve male (68.75%) and three female (31.25%) patients were included. A total of 19 percutaneous renal biopsies were performed (four patients required a second biopsy due to changes in clinical findings). Pathological findings revealed ten cases of acute tubular necrosis, four cases of acute rejection, and five cases with other (miscellaneous) diagnoses. Comparison between the four groups of interest failed to reveal significant differences (p=0.177) in cortical R2* values, whereas medullary R2* values differed significantly (p=0.033), with lower values in the miscellaneous diagnoses and the acute tubular necrosis group. Conclusion BOLD magnetic resonance imaging at 3 Tesla is a feasible technique that uses indirect tissue oxygen level measurements to differentiate between acute rejection and acute tubular necrosis in renal grafts. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082021000100225 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082021000100225 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.31744/einstein_journal/2021ao6069 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto Israelita de Ensino e Pesquisa Albert Einstein |
publisher.none.fl_str_mv |
Instituto Israelita de Ensino e Pesquisa Albert Einstein |
dc.source.none.fl_str_mv |
einstein (São Paulo) v.19 2021 reponame:Einstein (São Paulo) instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE) instacron:IIEPAE |
instname_str |
Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE) |
instacron_str |
IIEPAE |
institution |
IIEPAE |
reponame_str |
Einstein (São Paulo) |
collection |
Einstein (São Paulo) |
repository.name.fl_str_mv |
Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE) |
repository.mail.fl_str_mv |
||revista@einstein.br |
_version_ |
1752129910571270144 |