Determination of a method for extraction of coenzyme Q10 in human plasma: optimization of the use of surfactants and other variables

Detalhes bibliográficos
Autor(a) principal: Ferreiro-Barros,Claudia Cristina
Data de Publicação: 2012
Outros Autores: Sugawara,Eduardo Kinio, Sanches,Livia Rentas
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Einstein (São Paulo)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082012000200014
Resumo: OBJECTIVE: To establish a routine for the extraction of the total levels of CoQ10 in human plasma through the Ultra High Performance Liquid Chromatography (UHPLC). METHODS: Two extraction protocols were tested: a) methanol: hexane and b) 1-propanol. The following parameters were analyzed: extraction temperature (19ºC and 4ºC), extraction tubes (glass and polypropylene), and surfactants (SDS, Triton X-100, Tween-20) at different concentrations, i.e., 1%, 3%, 5% and 10%. RESULTS: The results showed that the method of extraction of CoQ10 in a sample of human plasma at 4ºC, using solvents methanol: hexane (85:15, v/v) in the presence of surfactant Tween-20 at 3% and polypropylene tubes showed better efficiency and reproducibility when compared to the method with 1-propanol. CONCLUSION: By the analyses performed, it was possible to observe that the addition of the surfactant Tween-20 promoted an increase in the recovery of CoQ10 by the methanol:hexane extraction method. This method showed good reproducibility, with a low coefficient of variation and high sensitivity, since CoQ10 was detected in samples of plasma of a control individual using a UV-type detector. The use of UHPLC equipment allowed a total analysis with total run time of 3.5 minutes, enabling the rapid achievement of results, considered mandatory for laboratory routines.
id IIEPAE-1_e85043f169105dd6a77b5c3b051d46ee
oai_identifier_str oai:scielo:S1679-45082012000200014
network_acronym_str IIEPAE-1
network_name_str Einstein (São Paulo)
repository_id_str
spelling Determination of a method for extraction of coenzyme Q10 in human plasma: optimization of the use of surfactants and other variablesCoenzymesSurfactantsChromatography, liquidOBJECTIVE: To establish a routine for the extraction of the total levels of CoQ10 in human plasma through the Ultra High Performance Liquid Chromatography (UHPLC). METHODS: Two extraction protocols were tested: a) methanol: hexane and b) 1-propanol. The following parameters were analyzed: extraction temperature (19ºC and 4ºC), extraction tubes (glass and polypropylene), and surfactants (SDS, Triton X-100, Tween-20) at different concentrations, i.e., 1%, 3%, 5% and 10%. RESULTS: The results showed that the method of extraction of CoQ10 in a sample of human plasma at 4ºC, using solvents methanol: hexane (85:15, v/v) in the presence of surfactant Tween-20 at 3% and polypropylene tubes showed better efficiency and reproducibility when compared to the method with 1-propanol. CONCLUSION: By the analyses performed, it was possible to observe that the addition of the surfactant Tween-20 promoted an increase in the recovery of CoQ10 by the methanol:hexane extraction method. This method showed good reproducibility, with a low coefficient of variation and high sensitivity, since CoQ10 was detected in samples of plasma of a control individual using a UV-type detector. The use of UHPLC equipment allowed a total analysis with total run time of 3.5 minutes, enabling the rapid achievement of results, considered mandatory for laboratory routines.Instituto Israelita de Ensino e Pesquisa Albert Einstein2012-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082012000200014einstein (São Paulo) v.10 n.2 2012reponame:Einstein (São Paulo)instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)instacron:IIEPAE10.1590/S1679-45082012000200014info:eu-repo/semantics/openAccessFerreiro-Barros,Claudia CristinaSugawara,Eduardo KinioSanches,Livia Rentaseng2012-09-20T00:00:00Zoai:scielo:S1679-45082012000200014Revistahttps://journal.einstein.br/pt-br/ONGhttps://old.scielo.br/oai/scielo-oai.php||revista@einstein.br2317-63851679-4508opendoar:2012-09-20T00:00Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)false
dc.title.none.fl_str_mv Determination of a method for extraction of coenzyme Q10 in human plasma: optimization of the use of surfactants and other variables
title Determination of a method for extraction of coenzyme Q10 in human plasma: optimization of the use of surfactants and other variables
spellingShingle Determination of a method for extraction of coenzyme Q10 in human plasma: optimization of the use of surfactants and other variables
Ferreiro-Barros,Claudia Cristina
Coenzymes
Surfactants
Chromatography, liquid
title_short Determination of a method for extraction of coenzyme Q10 in human plasma: optimization of the use of surfactants and other variables
title_full Determination of a method for extraction of coenzyme Q10 in human plasma: optimization of the use of surfactants and other variables
title_fullStr Determination of a method for extraction of coenzyme Q10 in human plasma: optimization of the use of surfactants and other variables
title_full_unstemmed Determination of a method for extraction of coenzyme Q10 in human plasma: optimization of the use of surfactants and other variables
title_sort Determination of a method for extraction of coenzyme Q10 in human plasma: optimization of the use of surfactants and other variables
author Ferreiro-Barros,Claudia Cristina
author_facet Ferreiro-Barros,Claudia Cristina
Sugawara,Eduardo Kinio
Sanches,Livia Rentas
author_role author
author2 Sugawara,Eduardo Kinio
Sanches,Livia Rentas
author2_role author
author
dc.contributor.author.fl_str_mv Ferreiro-Barros,Claudia Cristina
Sugawara,Eduardo Kinio
Sanches,Livia Rentas
dc.subject.por.fl_str_mv Coenzymes
Surfactants
Chromatography, liquid
topic Coenzymes
Surfactants
Chromatography, liquid
description OBJECTIVE: To establish a routine for the extraction of the total levels of CoQ10 in human plasma through the Ultra High Performance Liquid Chromatography (UHPLC). METHODS: Two extraction protocols were tested: a) methanol: hexane and b) 1-propanol. The following parameters were analyzed: extraction temperature (19ºC and 4ºC), extraction tubes (glass and polypropylene), and surfactants (SDS, Triton X-100, Tween-20) at different concentrations, i.e., 1%, 3%, 5% and 10%. RESULTS: The results showed that the method of extraction of CoQ10 in a sample of human plasma at 4ºC, using solvents methanol: hexane (85:15, v/v) in the presence of surfactant Tween-20 at 3% and polypropylene tubes showed better efficiency and reproducibility when compared to the method with 1-propanol. CONCLUSION: By the analyses performed, it was possible to observe that the addition of the surfactant Tween-20 promoted an increase in the recovery of CoQ10 by the methanol:hexane extraction method. This method showed good reproducibility, with a low coefficient of variation and high sensitivity, since CoQ10 was detected in samples of plasma of a control individual using a UV-type detector. The use of UHPLC equipment allowed a total analysis with total run time of 3.5 minutes, enabling the rapid achievement of results, considered mandatory for laboratory routines.
publishDate 2012
dc.date.none.fl_str_mv 2012-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082012000200014
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082012000200014
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1679-45082012000200014
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto Israelita de Ensino e Pesquisa Albert Einstein
publisher.none.fl_str_mv Instituto Israelita de Ensino e Pesquisa Albert Einstein
dc.source.none.fl_str_mv einstein (São Paulo) v.10 n.2 2012
reponame:Einstein (São Paulo)
instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
instacron:IIEPAE
instname_str Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
instacron_str IIEPAE
institution IIEPAE
reponame_str Einstein (São Paulo)
collection Einstein (São Paulo)
repository.name.fl_str_mv Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
repository.mail.fl_str_mv ||revista@einstein.br
_version_ 1752129906617090048