Detalhes bibliográficos
Autor(a) principal: Daniel,Ana Carolina Queiroz Godoy
Data de Publicação: 2017
Outros Autores: Machado,Juliana Pereira, Veiga,Eugenia Velludo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Einstein (São Paulo)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082017000100029
Resumo: ABSTRACT Objective To analyze the frequency of blood pressure documentation performed by nursing professionals in an emergency department. Methods This is a cross-sectional, observational, descriptive, and analytical study, which included medical records of adult patients admitted to the observation ward of an emergency department, between March and May 2014. Data were obtained through a collection instrument divided into three parts: patient identification, triage data, and blood pressure documentation. For statistical analysis, Pearson’s correlation coefficient was used, with a significance level of α<0.05. Results One hundred fifty-seven records and 430 blood pressure measurements were analyzed with an average of three measurements per patient. Of these measures, 46.5% were abnormal. The mean time from admission to documentation of the first blood pressure measurement was 2.5 minutes, with 42 minutes between subsequent measures. There is no correlation between the systolic blood pressure values and the mean time interval between blood pressure documentations: 0.173 (p=0.031). Conclusion The present study found no correlation between frequency of blood pressure documentation and blood pressure values. The frequency of blood pressure documentation increased according to the severity of the patient and decreased during the length of stay in the emergency department.
id IIEPAE-1_fd5b644b3ef3f0b05129505baf6905c9
oai_identifier_str oai:scielo:S1679-45082017000100029
network_acronym_str IIEPAE-1
network_name_str Einstein (São Paulo)
repository_id_str
spelling Blood pressure documentation in the emergency departmentNursing recordsBlood pressure determinationMonitoring, physiologicEmergency service, hospitalABSTRACT Objective To analyze the frequency of blood pressure documentation performed by nursing professionals in an emergency department. Methods This is a cross-sectional, observational, descriptive, and analytical study, which included medical records of adult patients admitted to the observation ward of an emergency department, between March and May 2014. Data were obtained through a collection instrument divided into three parts: patient identification, triage data, and blood pressure documentation. For statistical analysis, Pearson’s correlation coefficient was used, with a significance level of α<0.05. Results One hundred fifty-seven records and 430 blood pressure measurements were analyzed with an average of three measurements per patient. Of these measures, 46.5% were abnormal. The mean time from admission to documentation of the first blood pressure measurement was 2.5 minutes, with 42 minutes between subsequent measures. There is no correlation between the systolic blood pressure values and the mean time interval between blood pressure documentations: 0.173 (p=0.031). Conclusion The present study found no correlation between frequency of blood pressure documentation and blood pressure values. The frequency of blood pressure documentation increased according to the severity of the patient and decreased during the length of stay in the emergency department.Instituto Israelita de Ensino e Pesquisa Albert Einstein2017-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082017000100029einstein (São Paulo) v.15 n.1 2017reponame:Einstein (São Paulo)instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)instacron:IIEPAE10.1590/s1679-45082017ao3737info:eu-repo/semantics/openAccessDaniel,Ana Carolina Queiroz GodoyMachado,Juliana PereiraVeiga,Eugenia Velludoeng2017-10-16T00:00:00Zoai:scielo:S1679-45082017000100029Revistahttps://journal.einstein.br/pt-br/ONGhttps://old.scielo.br/oai/scielo-oai.php||revista@einstein.br2317-63851679-4508opendoar:2017-10-16T00:00Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)false
dc.title.none.fl_str_mv Blood pressure documentation in the emergency department
title Blood pressure documentation in the emergency department
spellingShingle Blood pressure documentation in the emergency department
Daniel,Ana Carolina Queiroz Godoy
Nursing records
Blood pressure determination
Monitoring, physiologic
Emergency service, hospital
title_short Blood pressure documentation in the emergency department
title_full Blood pressure documentation in the emergency department
title_fullStr Blood pressure documentation in the emergency department
title_full_unstemmed Blood pressure documentation in the emergency department
title_sort Blood pressure documentation in the emergency department
author Daniel,Ana Carolina Queiroz Godoy
author_facet Daniel,Ana Carolina Queiroz Godoy
Machado,Juliana Pereira
Veiga,Eugenia Velludo
author_role author
author2 Machado,Juliana Pereira
Veiga,Eugenia Velludo
author2_role author
author
dc.contributor.author.fl_str_mv Daniel,Ana Carolina Queiroz Godoy
Machado,Juliana Pereira
Veiga,Eugenia Velludo
dc.subject.por.fl_str_mv Nursing records
Blood pressure determination
Monitoring, physiologic
Emergency service, hospital
topic Nursing records
Blood pressure determination
Monitoring, physiologic
Emergency service, hospital
description ABSTRACT Objective To analyze the frequency of blood pressure documentation performed by nursing professionals in an emergency department. Methods This is a cross-sectional, observational, descriptive, and analytical study, which included medical records of adult patients admitted to the observation ward of an emergency department, between March and May 2014. Data were obtained through a collection instrument divided into three parts: patient identification, triage data, and blood pressure documentation. For statistical analysis, Pearson’s correlation coefficient was used, with a significance level of α<0.05. Results One hundred fifty-seven records and 430 blood pressure measurements were analyzed with an average of three measurements per patient. Of these measures, 46.5% were abnormal. The mean time from admission to documentation of the first blood pressure measurement was 2.5 minutes, with 42 minutes between subsequent measures. There is no correlation between the systolic blood pressure values and the mean time interval between blood pressure documentations: 0.173 (p=0.031). Conclusion The present study found no correlation between frequency of blood pressure documentation and blood pressure values. The frequency of blood pressure documentation increased according to the severity of the patient and decreased during the length of stay in the emergency department.
publishDate 2017
dc.date.none.fl_str_mv 2017-03-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082017000100029
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082017000100029
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1679-45082017ao3737
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto Israelita de Ensino e Pesquisa Albert Einstein
publisher.none.fl_str_mv Instituto Israelita de Ensino e Pesquisa Albert Einstein
dc.source.none.fl_str_mv einstein (São Paulo) v.15 n.1 2017
reponame:Einstein (São Paulo)
instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
instacron:IIEPAE
instname_str Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
instacron_str IIEPAE
institution IIEPAE
reponame_str Einstein (São Paulo)
collection Einstein (São Paulo)
repository.name.fl_str_mv Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)
repository.mail.fl_str_mv ||revista@einstein.br
_version_ 1752129908735213568