Resumo: | Objective : To investigate the influence of the site of measurement of transcutaneous bilirubin (forehead or sternum) in reproducibility of results as compared to plasma bilirubin. Methods : A cohort study including 58 term newborns with no hemolytic disease. Transcutaneous measurements were performed on the forehead (halfway between the headline and the glabella, from the left toward the right side, making consecutive determinations, one-centimeter apart) and the sternum (five measurements, from the suprasternal notch to the xiphoid process with consecutive determinations, one-centimeter apart) using Bilicheck® (SpectRx Inc, Norcross, Georgia, USA). The correlation and agreement between both methods and plasma bilirubin were calculated. Results : There was a strong linear correlation between both determinations of serum bilirubin at the forehead and sternum (r=0.704; p<0.01 and r=0.653; p<0.01, respectively). There was correspondence of the mean values of transcutaneous bilirubin measured on the sternum (9.9±2.2mg/dL) compared to plasma levels (10.2±1.7mg/dL), but both differ from the values measured on the forehead (8.6±2.0mg/dL), p<0.05. Conclusion : In newborn term infants with no hemolytic disease, measuring of transcutaneous bilirubin on the sternum had higher accuracy as compared to serum bilirubin measurement on the forehead. |
id |
IIEPAE-1_ffbf8ae8ea48a39bd732dcffe97cf9e2 |
---|---|
oai_identifier_str |
oai:scielo:S1679-45082014000100004 |
network_acronym_str |
IIEPAE-1 |
network_name_str |
Einstein (São Paulo) |
repository_id_str |
|
spelling |
Influence of assessment site in measuring transcutaneous bilirubinBilirubinJaundice, neonatal/diagnosisInfant, newborn Objective : To investigate the influence of the site of measurement of transcutaneous bilirubin (forehead or sternum) in reproducibility of results as compared to plasma bilirubin. Methods : A cohort study including 58 term newborns with no hemolytic disease. Transcutaneous measurements were performed on the forehead (halfway between the headline and the glabella, from the left toward the right side, making consecutive determinations, one-centimeter apart) and the sternum (five measurements, from the suprasternal notch to the xiphoid process with consecutive determinations, one-centimeter apart) using Bilicheck® (SpectRx Inc, Norcross, Georgia, USA). The correlation and agreement between both methods and plasma bilirubin were calculated. Results : There was a strong linear correlation between both determinations of serum bilirubin at the forehead and sternum (r=0.704; p<0.01 and r=0.653; p<0.01, respectively). There was correspondence of the mean values of transcutaneous bilirubin measured on the sternum (9.9±2.2mg/dL) compared to plasma levels (10.2±1.7mg/dL), but both differ from the values measured on the forehead (8.6±2.0mg/dL), p<0.05. Conclusion : In newborn term infants with no hemolytic disease, measuring of transcutaneous bilirubin on the sternum had higher accuracy as compared to serum bilirubin measurement on the forehead.Instituto Israelita de Ensino e Pesquisa Albert Einstein2014-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082014000100004einstein (São Paulo) v.12 n.1 2014reponame:Einstein (São Paulo)instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)instacron:IIEPAE10.1590/S1679-45082014AO2711info:eu-repo/semantics/openAccessConceição,Cristiane Maria daDornaus,Maria Fernanda Pellegrino da SilvaPortella,Maria AparecidaDeutsch,Alice D’AgostiniRebello,Celso Mouraeng2016-04-20T00:00:00Zoai:scielo:S1679-45082014000100004Revistahttps://journal.einstein.br/pt-br/ONGhttps://old.scielo.br/oai/scielo-oai.php||revista@einstein.br2317-63851679-4508opendoar:2016-04-20T00:00Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)false |
dc.title.none.fl_str_mv |
Influence of assessment site in measuring transcutaneous bilirubin |
title |
Influence of assessment site in measuring transcutaneous bilirubin |
spellingShingle |
Influence of assessment site in measuring transcutaneous bilirubin Conceição,Cristiane Maria da Bilirubin Jaundice, neonatal/diagnosis Infant, newborn |
title_short |
Influence of assessment site in measuring transcutaneous bilirubin |
title_full |
Influence of assessment site in measuring transcutaneous bilirubin |
title_fullStr |
Influence of assessment site in measuring transcutaneous bilirubin |
title_full_unstemmed |
Influence of assessment site in measuring transcutaneous bilirubin |
title_sort |
Influence of assessment site in measuring transcutaneous bilirubin |
author |
Conceição,Cristiane Maria da |
author_facet |
Conceição,Cristiane Maria da Dornaus,Maria Fernanda Pellegrino da Silva Portella,Maria Aparecida Deutsch,Alice D’Agostini Rebello,Celso Moura |
author_role |
author |
author2 |
Dornaus,Maria Fernanda Pellegrino da Silva Portella,Maria Aparecida Deutsch,Alice D’Agostini Rebello,Celso Moura |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Conceição,Cristiane Maria da Dornaus,Maria Fernanda Pellegrino da Silva Portella,Maria Aparecida Deutsch,Alice D’Agostini Rebello,Celso Moura |
dc.subject.por.fl_str_mv |
Bilirubin Jaundice, neonatal/diagnosis Infant, newborn |
topic |
Bilirubin Jaundice, neonatal/diagnosis Infant, newborn |
description |
Objective : To investigate the influence of the site of measurement of transcutaneous bilirubin (forehead or sternum) in reproducibility of results as compared to plasma bilirubin. Methods : A cohort study including 58 term newborns with no hemolytic disease. Transcutaneous measurements were performed on the forehead (halfway between the headline and the glabella, from the left toward the right side, making consecutive determinations, one-centimeter apart) and the sternum (five measurements, from the suprasternal notch to the xiphoid process with consecutive determinations, one-centimeter apart) using Bilicheck® (SpectRx Inc, Norcross, Georgia, USA). The correlation and agreement between both methods and plasma bilirubin were calculated. Results : There was a strong linear correlation between both determinations of serum bilirubin at the forehead and sternum (r=0.704; p<0.01 and r=0.653; p<0.01, respectively). There was correspondence of the mean values of transcutaneous bilirubin measured on the sternum (9.9±2.2mg/dL) compared to plasma levels (10.2±1.7mg/dL), but both differ from the values measured on the forehead (8.6±2.0mg/dL), p<0.05. Conclusion : In newborn term infants with no hemolytic disease, measuring of transcutaneous bilirubin on the sternum had higher accuracy as compared to serum bilirubin measurement on the forehead. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-03-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082014000100004 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082014000100004 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1679-45082014AO2711 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto Israelita de Ensino e Pesquisa Albert Einstein |
publisher.none.fl_str_mv |
Instituto Israelita de Ensino e Pesquisa Albert Einstein |
dc.source.none.fl_str_mv |
einstein (São Paulo) v.12 n.1 2014 reponame:Einstein (São Paulo) instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE) instacron:IIEPAE |
instname_str |
Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE) |
instacron_str |
IIEPAE |
institution |
IIEPAE |
reponame_str |
Einstein (São Paulo) |
collection |
Einstein (São Paulo) |
repository.name.fl_str_mv |
Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE) |
repository.mail.fl_str_mv |
||revista@einstein.br |
_version_ |
1752129907132989440 |