Acute toxoplasmosis: evaluation of the thin-layer immunoassay for detecting IgM antibodies to Toxoplasma gondii
Autor(a) principal: | |
---|---|
Data de Publicação: | 1990 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Revista do Instituto de Medicina Tropical de São Paulo |
Texto Completo: | https://www.revistas.usp.br/rimtsp/article/view/28708 |
Resumo: | A solid phase method, thin-layer immunoassay (IgM-TIA) was standardized and evaluated for the immunodiagnosis of acute toxoplasmosis, through the detection of IgM antibodies to Toxoplasma gondii. A total of 300 serum samples from serologically defined acute toxoplasmosis and, from non-related infections, was investigated by IgM-TIA. Statistical analysis were carried out in comparison with conventional tests, the immunofluorescence test for the detection of IgM antibodies (IgM-IFI) and hemagglutination test which uses 2-mercaptoetanol serum treatment (2ME-HA). Also the correlation coefficients were calculated for various Toxoplasma gondii antigen concentrations, as well as, the influence of the antigenic concentration on the relative indices of sensitivity and specificity were verified. The intra and inter test reproducibilities were demonstrated statistically, as well as, the reutilization of T. gondii antigen was proven to be possible for at least 10 times. The data indicated that antigenic concentrations, from 70 to 100 Çmg/ml, were able to provide maximum sensitivity and specificity. IgM-TIA displayed similar diagnostic efficiency to those two conventional tests here utilized, and may be employed to make diagnosis of acute toxoplasmosis, mainly if laboratory animals are avaiable. |
id |
IMT-1_53ec3110786be149054974d5dffc006c |
---|---|
oai_identifier_str |
oai:revistas.usp.br:article/28708 |
network_acronym_str |
IMT-1 |
network_name_str |
Revista do Instituto de Medicina Tropical de São Paulo |
repository_id_str |
|
spelling |
Acute toxoplasmosis: evaluation of the thin-layer immunoassay for detecting IgM antibodies to Toxoplasma gondii Toxoplasmose aguda: avaliação da técnica de imunoensaio em camada delgada para a detecção de anticorpos IgM, anti-Toxoplasma gondii Toxoplasmose agudaImunodiagnósticoAnticorpos IgM anti-Toxoplasma gondii A solid phase method, thin-layer immunoassay (IgM-TIA) was standardized and evaluated for the immunodiagnosis of acute toxoplasmosis, through the detection of IgM antibodies to Toxoplasma gondii. A total of 300 serum samples from serologically defined acute toxoplasmosis and, from non-related infections, was investigated by IgM-TIA. Statistical analysis were carried out in comparison with conventional tests, the immunofluorescence test for the detection of IgM antibodies (IgM-IFI) and hemagglutination test which uses 2-mercaptoetanol serum treatment (2ME-HA). Also the correlation coefficients were calculated for various Toxoplasma gondii antigen concentrations, as well as, the influence of the antigenic concentration on the relative indices of sensitivity and specificity were verified. The intra and inter test reproducibilities were demonstrated statistically, as well as, the reutilization of T. gondii antigen was proven to be possible for at least 10 times. The data indicated that antigenic concentrations, from 70 to 100 Çmg/ml, were able to provide maximum sensitivity and specificity. IgM-TIA displayed similar diagnostic efficiency to those two conventional tests here utilized, and may be employed to make diagnosis of acute toxoplasmosis, mainly if laboratory animals are avaiable. Um método de reação antígeno-anticorpo denominado IMUNOENSAIO EM CAMADA DELGADA (ICD) foi padronizado e avaliado para o imunodiagnóstico da toxoplasmose aguda, através da detecção de anticorpos IgM, anti-Toxoplasma gondii (ICD-IgM). Um total de 300 amostras de soros, tendo ou não o perfil sorológico da toxoplasmose aguda, foi estudado pelo ICD-IgM e os resultados analisados quanto aos aspectos qualitativos e quantitativos em relação aos testes convencionais de imunofluorecência indireta para a detecção de IgM, (IFI-IgM) e de hemaglutinação pré e após tratamento com 2-mercaptoetanol (HA-2ME). Foram calculados os coeficientes de correlação entre os resultados fornecidos pelo ICD-IgM e as técnicas convencionais, de acordo com as concentrações do antígeno, assim como, foi verificada a influência dessas concentrações antigênicas nos índices relativos de sensibilidade e de especificidade. O estudo estatístico mostrou reprodutibilidades significativas dos resultados inter e intra testes, assim como no reaproveitamento do antígeno por 10 vezes. Os resultados de ICD-IgM mostraram que as concentrações antigênicas ideais foram de 70 a 100µg/ml, para o ensaio em questão, para se obter máximas sensibilidade e especificidade. Portanto, ICD-IgM, por fornecer resultados tão sensíveis e específicos quanto aqueles dos testes convencionais referidos, poderá ser empregado para fins diagnósticos. Universidade de São Paulo. Instituto de Medicina Tropical de São Paulo1990-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/rimtsp/article/view/28708Revista do Instituto de Medicina Tropical de São Paulo; Vol. 32 No. 1 (1990); 51-57 Revista do Instituto de Medicina Tropical de São Paulo; Vol. 32 Núm. 1 (1990); 51-57 Revista do Instituto de Medicina Tropical de São Paulo; v. 32 n. 1 (1990); 51-57 1678-99460036-4665reponame:Revista do Instituto de Medicina Tropical de São Pauloinstname:Instituto de Medicina Tropical (IMT)instacron:IMTporhttps://www.revistas.usp.br/rimtsp/article/view/28708/30561Copyright (c) 2018 Revista do Instituto de Medicina Tropical de São Pauloinfo:eu-repo/semantics/openAccessRequejo, Henry Inácio ZanevanMatsumoto, Tokiko KyomenKawarabayashi, MassamiNakamura, Paulo MutukoEbner Filho, WaldemarNunes, José de Jesus Chaves2012-07-02T01:27:24Zoai:revistas.usp.br:article/28708Revistahttp://www.revistas.usp.br/rimtsp/indexPUBhttps://www.revistas.usp.br/rimtsp/oai||revimtsp@usp.br1678-99460036-4665opendoar:2022-12-13T16:50:27.600920Revista do Instituto de Medicina Tropical de São Paulo - Instituto de Medicina Tropical (IMT)true |
dc.title.none.fl_str_mv |
Acute toxoplasmosis: evaluation of the thin-layer immunoassay for detecting IgM antibodies to Toxoplasma gondii Toxoplasmose aguda: avaliação da técnica de imunoensaio em camada delgada para a detecção de anticorpos IgM, anti-Toxoplasma gondii |
title |
Acute toxoplasmosis: evaluation of the thin-layer immunoassay for detecting IgM antibodies to Toxoplasma gondii |
spellingShingle |
Acute toxoplasmosis: evaluation of the thin-layer immunoassay for detecting IgM antibodies to Toxoplasma gondii Requejo, Henry Inácio Zanevan Toxoplasmose aguda Imunodiagnóstico Anticorpos IgM anti-Toxoplasma gondii |
title_short |
Acute toxoplasmosis: evaluation of the thin-layer immunoassay for detecting IgM antibodies to Toxoplasma gondii |
title_full |
Acute toxoplasmosis: evaluation of the thin-layer immunoassay for detecting IgM antibodies to Toxoplasma gondii |
title_fullStr |
Acute toxoplasmosis: evaluation of the thin-layer immunoassay for detecting IgM antibodies to Toxoplasma gondii |
title_full_unstemmed |
Acute toxoplasmosis: evaluation of the thin-layer immunoassay for detecting IgM antibodies to Toxoplasma gondii |
title_sort |
Acute toxoplasmosis: evaluation of the thin-layer immunoassay for detecting IgM antibodies to Toxoplasma gondii |
author |
Requejo, Henry Inácio Zanevan |
author_facet |
Requejo, Henry Inácio Zanevan Matsumoto, Tokiko Kyomen Kawarabayashi, Massami Nakamura, Paulo Mutuko Ebner Filho, Waldemar Nunes, José de Jesus Chaves |
author_role |
author |
author2 |
Matsumoto, Tokiko Kyomen Kawarabayashi, Massami Nakamura, Paulo Mutuko Ebner Filho, Waldemar Nunes, José de Jesus Chaves |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Requejo, Henry Inácio Zanevan Matsumoto, Tokiko Kyomen Kawarabayashi, Massami Nakamura, Paulo Mutuko Ebner Filho, Waldemar Nunes, José de Jesus Chaves |
dc.subject.por.fl_str_mv |
Toxoplasmose aguda Imunodiagnóstico Anticorpos IgM anti-Toxoplasma gondii |
topic |
Toxoplasmose aguda Imunodiagnóstico Anticorpos IgM anti-Toxoplasma gondii |
description |
A solid phase method, thin-layer immunoassay (IgM-TIA) was standardized and evaluated for the immunodiagnosis of acute toxoplasmosis, through the detection of IgM antibodies to Toxoplasma gondii. A total of 300 serum samples from serologically defined acute toxoplasmosis and, from non-related infections, was investigated by IgM-TIA. Statistical analysis were carried out in comparison with conventional tests, the immunofluorescence test for the detection of IgM antibodies (IgM-IFI) and hemagglutination test which uses 2-mercaptoetanol serum treatment (2ME-HA). Also the correlation coefficients were calculated for various Toxoplasma gondii antigen concentrations, as well as, the influence of the antigenic concentration on the relative indices of sensitivity and specificity were verified. The intra and inter test reproducibilities were demonstrated statistically, as well as, the reutilization of T. gondii antigen was proven to be possible for at least 10 times. The data indicated that antigenic concentrations, from 70 to 100 Çmg/ml, were able to provide maximum sensitivity and specificity. IgM-TIA displayed similar diagnostic efficiency to those two conventional tests here utilized, and may be employed to make diagnosis of acute toxoplasmosis, mainly if laboratory animals are avaiable. |
publishDate |
1990 |
dc.date.none.fl_str_mv |
1990-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.revistas.usp.br/rimtsp/article/view/28708 |
url |
https://www.revistas.usp.br/rimtsp/article/view/28708 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://www.revistas.usp.br/rimtsp/article/view/28708/30561 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2018 Revista do Instituto de Medicina Tropical de São Paulo info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2018 Revista do Instituto de Medicina Tropical de São Paulo |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade de São Paulo. Instituto de Medicina Tropical de São Paulo |
publisher.none.fl_str_mv |
Universidade de São Paulo. Instituto de Medicina Tropical de São Paulo |
dc.source.none.fl_str_mv |
Revista do Instituto de Medicina Tropical de São Paulo; Vol. 32 No. 1 (1990); 51-57 Revista do Instituto de Medicina Tropical de São Paulo; Vol. 32 Núm. 1 (1990); 51-57 Revista do Instituto de Medicina Tropical de São Paulo; v. 32 n. 1 (1990); 51-57 1678-9946 0036-4665 reponame:Revista do Instituto de Medicina Tropical de São Paulo instname:Instituto de Medicina Tropical (IMT) instacron:IMT |
instname_str |
Instituto de Medicina Tropical (IMT) |
instacron_str |
IMT |
institution |
IMT |
reponame_str |
Revista do Instituto de Medicina Tropical de São Paulo |
collection |
Revista do Instituto de Medicina Tropical de São Paulo |
repository.name.fl_str_mv |
Revista do Instituto de Medicina Tropical de São Paulo - Instituto de Medicina Tropical (IMT) |
repository.mail.fl_str_mv |
||revimtsp@usp.br |
_version_ |
1798951638287777792 |