Low-cost flow photoreactor for degradation of Reactive Black 5 dye by UV/H2O2, Fenton and photo-Fenton processes: a performance comparison

Detalhes bibliográficos
Autor(a) principal: Silva,Andrea Maria da
Data de Publicação: 2021
Outros Autores: Santos,Tainá Natália dos, Santos,Raiane dos, Pessoa,Thiago Sabino, Anjos,Luiz Carlos Araújo dos, Silva Sobrinho,Nelson Alves da, Sales,Paula Barone da Paz
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Ambiente & Água
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1980-993X2021000300301
Resumo: Abstract In this work, a flow photoreactor was designed and set up using low-cost and recyclable parts to develop chemical treatments based on advanced oxidation processes (AOP) of highly colored textile wastewater. To evaluate this sustainable system´s efficiency, we investigated and compared the performance of three types of destructive methods (UV/H2O2, Fenton, and photo-Fenton) on the decolorization of aqueous solutions of Reactive Black 5 dye (RB5). We also analyzed the effect of the oxidant and dye concentrations on the rate of color removal in each one of the three methods. The results showed that, regardless of the initial operating conditions, the photo-Fenton process achieved the highest degradation rates, particularly when the highest ratio between the oxidant and dye concentrations was used ([H2O2]: [RB5] = 24.5 mg L-1: 25 mg L-1), leading to complete color removal within only 10 minutes of reaction. With the same initial condition, the Fenton and UV/H2O2 processes were also capable of removing the color entirely, even though they demanded more extended runs of 25 min. and 45 min., respectively. The effect of pH on the decolorization by the photo-Fenton process was also investigated, showing the same high performance at pHs 3 and 4. The degradation profile achieved by the photo-Fenton treatment was appropriately fitted by a pseudo-first-order kinetic. The non-expensive photoreactor proved to be quite useful for the degradation of the RB5, mainly when this azo dye underwent the photo-Fenton process.
id IPABHI-1_5f2673d735af25c40b19aec35e6ada96
oai_identifier_str oai:scielo:S1980-993X2021000300301
network_acronym_str IPABHI-1
network_name_str Revista Ambiente & Água
repository_id_str
spelling Low-cost flow photoreactor for degradation of Reactive Black 5 dye by UV/H2O2, Fenton and photo-Fenton processes: a performance comparisonadvanced oxidation processcolor removalReactive Black 5 dyetextile pollutantsAbstract In this work, a flow photoreactor was designed and set up using low-cost and recyclable parts to develop chemical treatments based on advanced oxidation processes (AOP) of highly colored textile wastewater. To evaluate this sustainable system´s efficiency, we investigated and compared the performance of three types of destructive methods (UV/H2O2, Fenton, and photo-Fenton) on the decolorization of aqueous solutions of Reactive Black 5 dye (RB5). We also analyzed the effect of the oxidant and dye concentrations on the rate of color removal in each one of the three methods. The results showed that, regardless of the initial operating conditions, the photo-Fenton process achieved the highest degradation rates, particularly when the highest ratio between the oxidant and dye concentrations was used ([H2O2]: [RB5] = 24.5 mg L-1: 25 mg L-1), leading to complete color removal within only 10 minutes of reaction. With the same initial condition, the Fenton and UV/H2O2 processes were also capable of removing the color entirely, even though they demanded more extended runs of 25 min. and 45 min., respectively. The effect of pH on the decolorization by the photo-Fenton process was also investigated, showing the same high performance at pHs 3 and 4. The degradation profile achieved by the photo-Fenton treatment was appropriately fitted by a pseudo-first-order kinetic. The non-expensive photoreactor proved to be quite useful for the degradation of the RB5, mainly when this azo dye underwent the photo-Fenton process.Instituto de Pesquisas Ambientais em Bacias Hidrográficas2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1980-993X2021000300301Revista Ambiente & Água v.16 n.3 2021reponame:Revista Ambiente & Águainstname:Instituto de Pesquisas Ambientais em Bacias Hidrográficas (IPABHI)instacron:IPABHI10.4136/ambi-agua.2687info:eu-repo/semantics/openAccessSilva,Andrea Maria daSantos,Tainá Natália dosSantos,Raiane dosPessoa,Thiago SabinoAnjos,Luiz Carlos Araújo dosSilva Sobrinho,Nelson Alves daSales,Paula Barone da Pazeng2021-05-27T00:00:00Zoai:scielo:S1980-993X2021000300301Revistahttp://www.ambi-agua.net/PUBhttps://old.scielo.br/oai/scielo-oai.php||ambi.agua@gmail.com1980-993X1980-993Xopendoar:2021-05-27T00:00Revista Ambiente & Água - Instituto de Pesquisas Ambientais em Bacias Hidrográficas (IPABHI)false
dc.title.none.fl_str_mv Low-cost flow photoreactor for degradation of Reactive Black 5 dye by UV/H2O2, Fenton and photo-Fenton processes: a performance comparison
title Low-cost flow photoreactor for degradation of Reactive Black 5 dye by UV/H2O2, Fenton and photo-Fenton processes: a performance comparison
spellingShingle Low-cost flow photoreactor for degradation of Reactive Black 5 dye by UV/H2O2, Fenton and photo-Fenton processes: a performance comparison
Silva,Andrea Maria da
advanced oxidation process
color removal
Reactive Black 5 dye
textile pollutants
title_short Low-cost flow photoreactor for degradation of Reactive Black 5 dye by UV/H2O2, Fenton and photo-Fenton processes: a performance comparison
title_full Low-cost flow photoreactor for degradation of Reactive Black 5 dye by UV/H2O2, Fenton and photo-Fenton processes: a performance comparison
title_fullStr Low-cost flow photoreactor for degradation of Reactive Black 5 dye by UV/H2O2, Fenton and photo-Fenton processes: a performance comparison
title_full_unstemmed Low-cost flow photoreactor for degradation of Reactive Black 5 dye by UV/H2O2, Fenton and photo-Fenton processes: a performance comparison
title_sort Low-cost flow photoreactor for degradation of Reactive Black 5 dye by UV/H2O2, Fenton and photo-Fenton processes: a performance comparison
author Silva,Andrea Maria da
author_facet Silva,Andrea Maria da
Santos,Tainá Natália dos
Santos,Raiane dos
Pessoa,Thiago Sabino
Anjos,Luiz Carlos Araújo dos
Silva Sobrinho,Nelson Alves da
Sales,Paula Barone da Paz
author_role author
author2 Santos,Tainá Natália dos
Santos,Raiane dos
Pessoa,Thiago Sabino
Anjos,Luiz Carlos Araújo dos
Silva Sobrinho,Nelson Alves da
Sales,Paula Barone da Paz
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Silva,Andrea Maria da
Santos,Tainá Natália dos
Santos,Raiane dos
Pessoa,Thiago Sabino
Anjos,Luiz Carlos Araújo dos
Silva Sobrinho,Nelson Alves da
Sales,Paula Barone da Paz
dc.subject.por.fl_str_mv advanced oxidation process
color removal
Reactive Black 5 dye
textile pollutants
topic advanced oxidation process
color removal
Reactive Black 5 dye
textile pollutants
description Abstract In this work, a flow photoreactor was designed and set up using low-cost and recyclable parts to develop chemical treatments based on advanced oxidation processes (AOP) of highly colored textile wastewater. To evaluate this sustainable system´s efficiency, we investigated and compared the performance of three types of destructive methods (UV/H2O2, Fenton, and photo-Fenton) on the decolorization of aqueous solutions of Reactive Black 5 dye (RB5). We also analyzed the effect of the oxidant and dye concentrations on the rate of color removal in each one of the three methods. The results showed that, regardless of the initial operating conditions, the photo-Fenton process achieved the highest degradation rates, particularly when the highest ratio between the oxidant and dye concentrations was used ([H2O2]: [RB5] = 24.5 mg L-1: 25 mg L-1), leading to complete color removal within only 10 minutes of reaction. With the same initial condition, the Fenton and UV/H2O2 processes were also capable of removing the color entirely, even though they demanded more extended runs of 25 min. and 45 min., respectively. The effect of pH on the decolorization by the photo-Fenton process was also investigated, showing the same high performance at pHs 3 and 4. The degradation profile achieved by the photo-Fenton treatment was appropriately fitted by a pseudo-first-order kinetic. The non-expensive photoreactor proved to be quite useful for the degradation of the RB5, mainly when this azo dye underwent the photo-Fenton process.
publishDate 2021
dc.date.none.fl_str_mv 2021-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1980-993X2021000300301
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1980-993X2021000300301
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.4136/ambi-agua.2687
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto de Pesquisas Ambientais em Bacias Hidrográficas
publisher.none.fl_str_mv Instituto de Pesquisas Ambientais em Bacias Hidrográficas
dc.source.none.fl_str_mv Revista Ambiente & Água v.16 n.3 2021
reponame:Revista Ambiente & Água
instname:Instituto de Pesquisas Ambientais em Bacias Hidrográficas (IPABHI)
instacron:IPABHI
instname_str Instituto de Pesquisas Ambientais em Bacias Hidrográficas (IPABHI)
instacron_str IPABHI
institution IPABHI
reponame_str Revista Ambiente & Água
collection Revista Ambiente & Água
repository.name.fl_str_mv Revista Ambiente & Água - Instituto de Pesquisas Ambientais em Bacias Hidrográficas (IPABHI)
repository.mail.fl_str_mv ||ambi.agua@gmail.com
_version_ 1752129751648043008