Lower plenum holes for research reactor core flooding

Detalhes bibliográficos
Autor(a) principal: MAPRELIAN, EDUARDO
Data de Publicação: 2020
Outros Autores: BELCHIOR JUNIOR, ANTONIO, TORRES, WALMIR M., INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE
Tipo de documento: Artigo de conferência
Título da fonte: Repositório Institucional do IPEN
Texto Completo: http://repositorio.ipen.br/handle/123456789/30700
Resumo: Modern and high power pool type research reactors generally operate with upward flow in the core. They have a chimney above the core, where the heated fluid is suctioned by the pumps. It passes through the decay tank and is sent to the heat exchangers for the cooling and returns to the core. The pipes inside the reactor pool have passive valves (natural circulation valves) that allow the establishment of natural circulation between the core and the pool for the decay heat removal, when the pumps are inoperative. These valves also have the siphon-breaker function in case of Loss of Coolant Accidents (LOCA), avoiding the pool emptying. In some reactors, these valves are located above the core chimney to facilitate the maintenance. When a LOCA causes a water level below these valves, they loose the natural circulation function. If the water level is the same of the chimney top, the available fluid for the core cooling is only that contained in the chimney and core, and a significant quantity of water in the pool is unavailable for core cooling. To bypass this problem during the reactor design phase, the inclusion of small holes of 10 mm of diameter on the lower plenum lateral side is proposed. These holes will allow a flow path between the pool and the core. Theoretical calculations were performed and analyzed for different drilling configurations: 4, 6 8, and 10 holes. A theoretical analysis of the estimated leakage rate during normal operation and evaporation and replacement rates during a hypothetical LOCA were performed. The calculation results showed that the four configurations analyzed are able to supply the water evaporated from chimney. An experiment is being proposed to validate the theoretical calculations and the considered hypotheses.
id IPEN_b37714b018fa3769d9c093ebacce3f4c
oai_identifier_str oai:repositorio.ipen.br:123456789/30700
network_acronym_str IPEN
network_name_str Repositório Institucional do IPEN
repository_id_str 4510
spelling 2020-01-15T13:39:56Z2020-01-15T13:39:56ZOctober 21-25, 2019http://repositorio.ipen.br/handle/123456789/30700Modern and high power pool type research reactors generally operate with upward flow in the core. They have a chimney above the core, where the heated fluid is suctioned by the pumps. It passes through the decay tank and is sent to the heat exchangers for the cooling and returns to the core. The pipes inside the reactor pool have passive valves (natural circulation valves) that allow the establishment of natural circulation between the core and the pool for the decay heat removal, when the pumps are inoperative. These valves also have the siphon-breaker function in case of Loss of Coolant Accidents (LOCA), avoiding the pool emptying. In some reactors, these valves are located above the core chimney to facilitate the maintenance. When a LOCA causes a water level below these valves, they loose the natural circulation function. If the water level is the same of the chimney top, the available fluid for the core cooling is only that contained in the chimney and core, and a significant quantity of water in the pool is unavailable for core cooling. To bypass this problem during the reactor design phase, the inclusion of small holes of 10 mm of diameter on the lower plenum lateral side is proposed. These holes will allow a flow path between the pool and the core. Theoretical calculations were performed and analyzed for different drilling configurations: 4, 6 8, and 10 holes. A theoretical analysis of the estimated leakage rate during normal operation and evaporation and replacement rates during a hypothetical LOCA were performed. The calculation results showed that the four configurations analyzed are able to supply the water evaporated from chimney. An experiment is being proposed to validate the theoretical calculations and the considered hypotheses.Submitted by Celia Satomi Uehara (celia.u-topservice@ipen.br) on 2020-01-15T13:39:56Z No. of bitstreams: 1 26349.pdf: 619196 bytes, checksum: 55c03f1f895b8ba5350c3cafb2fc9cef (MD5)Made available in DSpace on 2020-01-15T13:39:56Z (GMT). No. of bitstreams: 1 26349.pdf: 619196 bytes, checksum: 55c03f1f895b8ba5350c3cafb2fc9cef (MD5)4631-4639Associa????o Brasileira de Energia Nuclearcore flooding systemsexperimental dataflow rateholesleaksloss of coolantnatural convectionpool type reactorsprimary coolant circuitsreactor coresreactor safetyresearch reactorstheoretical datavalvesLower plenum holes for research reactor core floodinginfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObjectINACIRio de JaneiroSantos, SP7366367188600600600MAPRELIAN, EDUARDOBELCHIOR JUNIOR, ANTONIOTORRES, WALMIR M.INTERNATIONAL NUCLEAR ATLANTIC CONFERENCEinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional do IPENinstname:Instituto de Pesquisas Energéticas e Nucleares (IPEN)instacron:IPEN263492019TORRES, WALMIR M.BELCHIOR JUNIOR, ANTONIOMAPRELIAN, EDUARDO20-01Proceedings1886367736a proposal to improve the safety in designTORRES, WALMIR M.:188:450:NBELCHIOR JUNIOR, ANTONIO:6367:450:NMAPRELIAN, EDUARDO:736:420:SORIGINAL26349.pdf26349.pdfapplication/pdf619196http://repositorio.ipen.br/bitstream/123456789/30700/1/26349.pdf55c03f1f895b8ba5350c3cafb2fc9cefMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://repositorio.ipen.br/bitstream/123456789/30700/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52123456789/307002020-04-10 00:07:18.425oai:repositorio.ipen.br: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Repositório InstitucionalPUBhttp://repositorio.ipen.br/oai/requestbibl@ipen.bropendoar:45102020-04-10T00:07:18Repositório Institucional do IPEN - Instituto de Pesquisas Energéticas e Nucleares (IPEN)false
dc.title.pt_BR.fl_str_mv Lower plenum holes for research reactor core flooding
title Lower plenum holes for research reactor core flooding
spellingShingle Lower plenum holes for research reactor core flooding
MAPRELIAN, EDUARDO
core flooding systems
experimental data
flow rate
holes
leaks
loss of coolant
natural convection
pool type reactors
primary coolant circuits
reactor cores
reactor safety
research reactors
theoretical data
valves
title_short Lower plenum holes for research reactor core flooding
title_full Lower plenum holes for research reactor core flooding
title_fullStr Lower plenum holes for research reactor core flooding
title_full_unstemmed Lower plenum holes for research reactor core flooding
title_sort Lower plenum holes for research reactor core flooding
author MAPRELIAN, EDUARDO
author_facet MAPRELIAN, EDUARDO
BELCHIOR JUNIOR, ANTONIO
TORRES, WALMIR M.
INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE
author_role author
author2 BELCHIOR JUNIOR, ANTONIO
TORRES, WALMIR M.
INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE
author2_role author
author
author
dc.contributor.author.fl_str_mv MAPRELIAN, EDUARDO
BELCHIOR JUNIOR, ANTONIO
TORRES, WALMIR M.
INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE
dc.subject.por.fl_str_mv core flooding systems
experimental data
flow rate
holes
leaks
loss of coolant
natural convection
pool type reactors
primary coolant circuits
reactor cores
reactor safety
research reactors
theoretical data
valves
topic core flooding systems
experimental data
flow rate
holes
leaks
loss of coolant
natural convection
pool type reactors
primary coolant circuits
reactor cores
reactor safety
research reactors
theoretical data
valves
description Modern and high power pool type research reactors generally operate with upward flow in the core. They have a chimney above the core, where the heated fluid is suctioned by the pumps. It passes through the decay tank and is sent to the heat exchangers for the cooling and returns to the core. The pipes inside the reactor pool have passive valves (natural circulation valves) that allow the establishment of natural circulation between the core and the pool for the decay heat removal, when the pumps are inoperative. These valves also have the siphon-breaker function in case of Loss of Coolant Accidents (LOCA), avoiding the pool emptying. In some reactors, these valves are located above the core chimney to facilitate the maintenance. When a LOCA causes a water level below these valves, they loose the natural circulation function. If the water level is the same of the chimney top, the available fluid for the core cooling is only that contained in the chimney and core, and a significant quantity of water in the pool is unavailable for core cooling. To bypass this problem during the reactor design phase, the inclusion of small holes of 10 mm of diameter on the lower plenum lateral side is proposed. These holes will allow a flow path between the pool and the core. Theoretical calculations were performed and analyzed for different drilling configurations: 4, 6 8, and 10 holes. A theoretical analysis of the estimated leakage rate during normal operation and evaporation and replacement rates during a hypothetical LOCA were performed. The calculation results showed that the four configurations analyzed are able to supply the water evaporated from chimney. An experiment is being proposed to validate the theoretical calculations and the considered hypotheses.
publishDate 2020
dc.date.evento.pt_BR.fl_str_mv October 21-25, 2019
dc.date.accessioned.fl_str_mv 2020-01-15T13:39:56Z
dc.date.available.fl_str_mv 2020-01-15T13:39:56Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/conferenceObject
format conferenceObject
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ipen.br/handle/123456789/30700
url http://repositorio.ipen.br/handle/123456789/30700
dc.relation.authority.fl_str_mv 736
6367
188
dc.relation.confidence.fl_str_mv 600
600
600
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 4631-4639
dc.coverage.pt_BR.fl_str_mv I
dc.publisher.none.fl_str_mv Associa????o Brasileira de Energia Nuclear
publisher.none.fl_str_mv Associa????o Brasileira de Energia Nuclear
dc.source.none.fl_str_mv reponame:Repositório Institucional do IPEN
instname:Instituto de Pesquisas Energéticas e Nucleares (IPEN)
instacron:IPEN
instname_str Instituto de Pesquisas Energéticas e Nucleares (IPEN)
instacron_str IPEN
institution IPEN
reponame_str Repositório Institucional do IPEN
collection Repositório Institucional do IPEN
bitstream.url.fl_str_mv http://repositorio.ipen.br/bitstream/123456789/30700/1/26349.pdf
http://repositorio.ipen.br/bitstream/123456789/30700/2/license.txt
bitstream.checksum.fl_str_mv 55c03f1f895b8ba5350c3cafb2fc9cef
8a4605be74aa9ea9d79846c1fba20a33
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositório Institucional do IPEN - Instituto de Pesquisas Energéticas e Nucleares (IPEN)
repository.mail.fl_str_mv bibl@ipen.br
_version_ 1767254250540236800