Design and evaluation of a Physical Protection System for a radioactive waste intermediary storage
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da Produção Científica da Marinha do Brasil (RI-MB) |
Texto Completo: | https://www.repositorio.mar.mil.br/handle/ripcmb/846005 https://doi.org/10.15392/2319-0612.2022.2097 |
Resumo: | The present work aimed to describe, present, and evaluate a Physical Protection System (PPS) for a hypothetical facility of an intermediate radioactive waste deposit, following international and national security criteria. Therefore, it carried out an evaluation of the Physical Protection System (PPS) applying the DEPO (Design and Evaluation Process Outline) methodology with a sequence of three phases of the protection system design and assessment of its vulnerabilities. The overall assessment of PPS was performed from the calculation of the overall probability of system effectiveness (PE) through the methods of adversary sequence diagrams, path analysis, and neutralization analysis. PPS presented a PE value of only 6.5%, three improvements were proposed and their impacts were analyzed. The reduction of the response time of the security forces led to a value of 78% of the PE and the increase of the time delay (TD) in the barriers closer to the target made the PPS efficiency reach 92%, higher than the acceptable value of 85%. The results showed that the evaluation of the proposed hypothetical project allowed adaptations so that the ideal level of PPS effectiveness could be reached with few interventions. The initial project was prepared in accordance with current regulations (traditional prescriptive approach) and, even so, presented a low probability of overall effectiveness, leading to the need for adjustments that were only possible by applying the DEPO methodology (performance-based approach). |
id |
MB_e44325ba545eb955946a1d4298b93e10 |
---|---|
oai_identifier_str |
oai:www.repositorio.mar.mil.br:ripcmb/846005 |
network_acronym_str |
MB |
network_name_str |
Repositório Institucional da Produção Científica da Marinha do Brasil (RI-MB) |
repository_id_str |
|
spelling |
Vasconcelos, Victor de CastroFontes, Gladson SilvaTavares, Renato Luiz2023-03-21T14:07:21Z2023-03-21T14:07:21Z2022VASCONCELOS, V. de C.; FONTES, G. S.; TAVARES, R. L. Design and Evaluation of a Physical Protection System for a Radioactive Waste Intermediary Storage. Brazilian Journal of Radiation Sciences, [S. l.], v. 10, n. 4, p. 1–17, 2022. DOI: 10.15392/2319-0612.2022.2097.2319-0612https://www.repositorio.mar.mil.br/handle/ripcmb/846005https://doi.org/10.15392/2319-0612.2022.2097The present work aimed to describe, present, and evaluate a Physical Protection System (PPS) for a hypothetical facility of an intermediate radioactive waste deposit, following international and national security criteria. Therefore, it carried out an evaluation of the Physical Protection System (PPS) applying the DEPO (Design and Evaluation Process Outline) methodology with a sequence of three phases of the protection system design and assessment of its vulnerabilities. The overall assessment of PPS was performed from the calculation of the overall probability of system effectiveness (PE) through the methods of adversary sequence diagrams, path analysis, and neutralization analysis. PPS presented a PE value of only 6.5%, three improvements were proposed and their impacts were analyzed. The reduction of the response time of the security forces led to a value of 78% of the PE and the increase of the time delay (TD) in the barriers closer to the target made the PPS efficiency reach 92%, higher than the acceptable value of 85%. The results showed that the evaluation of the proposed hypothetical project allowed adaptations so that the ideal level of PPS effectiveness could be reached with few interventions. The initial project was prepared in accordance with current regulations (traditional prescriptive approach) and, even so, presented a low probability of overall effectiveness, leading to the need for adjustments that were only possible by applying the DEPO methodology (performance-based approach).Brazilian Journal of Radiation Sciences (BJRS)Engenharia nuclearNuclear securityNuclear waste storagePhysical Protection SystemDesign and evaluation of a Physical Protection System for a radioactive waste intermediary storageinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleinfo:eu-repo/semantics/openAccessengreponame:Repositório Institucional da Produção Científica da Marinha do Brasil (RI-MB)instname:Marinha do Brasil (MB)instacron:MBORIGINALArtigo_Victor_Vasconcelos.pdfArtigo_Victor_Vasconcelos.pdfapplication/pdf630597https://www.repositorio.mar.mil.br/bitstream/ripcmb/846005/1/Artigo_Victor_Vasconcelos.pdf6b93a5ebf97945bffb280291d39eb406MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-83272https://www.repositorio.mar.mil.br/bitstream/ripcmb/846005/2/license.txt8ff7ce654d5215cee2106f3e3b7eb37fMD52TEXTArtigo_Victor_Vasconcelos.pdf.txtArtigo_Victor_Vasconcelos.pdf.txtExtracted texttext/plain32021https://www.repositorio.mar.mil.br/bitstream/ripcmb/846005/3/Artigo_Victor_Vasconcelos.pdf.txtaea0d210c2cf2359475c9180e55434c0MD53THUMBNAILArtigo_Victor_Vasconcelos.pdf.jpgArtigo_Victor_Vasconcelos.pdf.jpgGenerated Thumbnailimage/jpeg1696https://www.repositorio.mar.mil.br/bitstream/ripcmb/846005/4/Artigo_Victor_Vasconcelos.pdf.jpg195609083b7dd76c00e2d2cf86d9868bMD54ripcmb/8460052023-05-12 10:27:32.848oai:www.repositorio.mar.mil.br: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Repositório InstitucionalPUBhttps://www.repositorio.mar.mil.br/oai/requestdphdm.repositorio@marinha.mil.bropendoar:2023-05-12T13:27:32Repositório Institucional da Produção Científica da Marinha do Brasil (RI-MB) - Marinha do Brasil (MB)false |
dc.title.pt_BR.fl_str_mv |
Design and evaluation of a Physical Protection System for a radioactive waste intermediary storage |
title |
Design and evaluation of a Physical Protection System for a radioactive waste intermediary storage |
spellingShingle |
Design and evaluation of a Physical Protection System for a radioactive waste intermediary storage Vasconcelos, Victor de Castro Nuclear security Nuclear waste storage Physical Protection System Engenharia nuclear |
title_short |
Design and evaluation of a Physical Protection System for a radioactive waste intermediary storage |
title_full |
Design and evaluation of a Physical Protection System for a radioactive waste intermediary storage |
title_fullStr |
Design and evaluation of a Physical Protection System for a radioactive waste intermediary storage |
title_full_unstemmed |
Design and evaluation of a Physical Protection System for a radioactive waste intermediary storage |
title_sort |
Design and evaluation of a Physical Protection System for a radioactive waste intermediary storage |
author |
Vasconcelos, Victor de Castro |
author_facet |
Vasconcelos, Victor de Castro Fontes, Gladson Silva Tavares, Renato Luiz |
author_role |
author |
author2 |
Fontes, Gladson Silva Tavares, Renato Luiz |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Vasconcelos, Victor de Castro Fontes, Gladson Silva Tavares, Renato Luiz |
dc.subject.por.fl_str_mv |
Nuclear security Nuclear waste storage Physical Protection System |
topic |
Nuclear security Nuclear waste storage Physical Protection System Engenharia nuclear |
dc.subject.dgpm.pt_BR.fl_str_mv |
Engenharia nuclear |
description |
The present work aimed to describe, present, and evaluate a Physical Protection System (PPS) for a hypothetical facility of an intermediate radioactive waste deposit, following international and national security criteria. Therefore, it carried out an evaluation of the Physical Protection System (PPS) applying the DEPO (Design and Evaluation Process Outline) methodology with a sequence of three phases of the protection system design and assessment of its vulnerabilities. The overall assessment of PPS was performed from the calculation of the overall probability of system effectiveness (PE) through the methods of adversary sequence diagrams, path analysis, and neutralization analysis. PPS presented a PE value of only 6.5%, three improvements were proposed and their impacts were analyzed. The reduction of the response time of the security forces led to a value of 78% of the PE and the increase of the time delay (TD) in the barriers closer to the target made the PPS efficiency reach 92%, higher than the acceptable value of 85%. The results showed that the evaluation of the proposed hypothetical project allowed adaptations so that the ideal level of PPS effectiveness could be reached with few interventions. The initial project was prepared in accordance with current regulations (traditional prescriptive approach) and, even so, presented a low probability of overall effectiveness, leading to the need for adjustments that were only possible by applying the DEPO methodology (performance-based approach). |
publishDate |
2022 |
dc.date.issued.fl_str_mv |
2022 |
dc.date.accessioned.fl_str_mv |
2023-03-21T14:07:21Z |
dc.date.available.fl_str_mv |
2023-03-21T14:07:21Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
VASCONCELOS, V. de C.; FONTES, G. S.; TAVARES, R. L. Design and Evaluation of a Physical Protection System for a Radioactive Waste Intermediary Storage. Brazilian Journal of Radiation Sciences, [S. l.], v. 10, n. 4, p. 1–17, 2022. DOI: 10.15392/2319-0612.2022.2097. |
dc.identifier.uri.fl_str_mv |
https://www.repositorio.mar.mil.br/handle/ripcmb/846005 |
dc.identifier.issn.none.fl_str_mv |
2319-0612 |
dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.15392/2319-0612.2022.2097 |
identifier_str_mv |
VASCONCELOS, V. de C.; FONTES, G. S.; TAVARES, R. L. Design and Evaluation of a Physical Protection System for a Radioactive Waste Intermediary Storage. Brazilian Journal of Radiation Sciences, [S. l.], v. 10, n. 4, p. 1–17, 2022. DOI: 10.15392/2319-0612.2022.2097. 2319-0612 |
url |
https://www.repositorio.mar.mil.br/handle/ripcmb/846005 https://doi.org/10.15392/2319-0612.2022.2097 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Brazilian Journal of Radiation Sciences (BJRS) |
publisher.none.fl_str_mv |
Brazilian Journal of Radiation Sciences (BJRS) |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da Produção Científica da Marinha do Brasil (RI-MB) instname:Marinha do Brasil (MB) instacron:MB |
instname_str |
Marinha do Brasil (MB) |
instacron_str |
MB |
institution |
MB |
reponame_str |
Repositório Institucional da Produção Científica da Marinha do Brasil (RI-MB) |
collection |
Repositório Institucional da Produção Científica da Marinha do Brasil (RI-MB) |
bitstream.url.fl_str_mv |
https://www.repositorio.mar.mil.br/bitstream/ripcmb/846005/1/Artigo_Victor_Vasconcelos.pdf https://www.repositorio.mar.mil.br/bitstream/ripcmb/846005/2/license.txt https://www.repositorio.mar.mil.br/bitstream/ripcmb/846005/3/Artigo_Victor_Vasconcelos.pdf.txt https://www.repositorio.mar.mil.br/bitstream/ripcmb/846005/4/Artigo_Victor_Vasconcelos.pdf.jpg |
bitstream.checksum.fl_str_mv |
6b93a5ebf97945bffb280291d39eb406 8ff7ce654d5215cee2106f3e3b7eb37f aea0d210c2cf2359475c9180e55434c0 195609083b7dd76c00e2d2cf86d9868b |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da Produção Científica da Marinha do Brasil (RI-MB) - Marinha do Brasil (MB) |
repository.mail.fl_str_mv |
dphdm.repositorio@marinha.mil.br |
_version_ |
1813189023666012160 |