Positive correlation of postural balance evaluation by two different devices in community dwelling women
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | MedicalExpress (São Paulo. Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2358-04292016000200003 |
Resumo: | OBJECTIVE: To establish the convergent validity or relationship of the Balance Master® as balance assessment device by comparing its performance results with those obtained from the AccuSway Plus® force plate. METHOD: Cross-sectional observational study, without intervention, of 126 postmenopausal women (60.3 ± 3.2 years; body mass index = 27.6 ± 4.7 kg/m2). Two devices were used for the independent assessments of static balance: (a) Static postural balance assessment (posturography) was performed on a force platform (AccuSway Plus); (b) static evaluation was performed on the Balance Master®System. The variables studied in the two devices, were: (i) the Mean Velocity of the Center of Pressure Displacement in all directions (Vavg or Mean Firm), (ii) the Anteroposterior (Mean-Y) and (iii) the Mediolateral (Mean-X) Centers of Pressure Displacement. The Spearman correlation coefficient was calculated to measure the correlation of the variables of balance obtained with the two different devices. RESULTS: Significant correlations were obtained when the relationships between both variables were described by fitting multiple linear regression models. There was an association between the mean velocity of center of pressure displacement in both devices, with eyes open (r = 0.21) and eyes closed (r = 0.47). In the eyes open condition, Vavg increased, on average, 0.26 units, while Mean Firm increased 1.0 unit; in the Mean-Firm; in eyes closed condition, Vavg increased, on average, 1.27 units, while Mean-Firm increased by 1,0 unit. CONCLUSION: The devices investigated presented a significant correlation for the mean velocity calculated from the total displacement of the center of pressure in all directions. |
id |
METC-1_a2e72991bae0447bdaded78c326b3d8f |
---|---|
oai_identifier_str |
oai:scielo:S2358-04292016000200003 |
network_acronym_str |
METC-1 |
network_name_str |
MedicalExpress (São Paulo. Online) |
repository_id_str |
|
spelling |
Positive correlation of postural balance evaluation by two different devices in community dwelling womenPostural balanceCenter of pressureDeviceForce platePostmenopausal OBJECTIVE: To establish the convergent validity or relationship of the Balance Master® as balance assessment device by comparing its performance results with those obtained from the AccuSway Plus® force plate. METHOD: Cross-sectional observational study, without intervention, of 126 postmenopausal women (60.3 ± 3.2 years; body mass index = 27.6 ± 4.7 kg/m2). Two devices were used for the independent assessments of static balance: (a) Static postural balance assessment (posturography) was performed on a force platform (AccuSway Plus); (b) static evaluation was performed on the Balance Master®System. The variables studied in the two devices, were: (i) the Mean Velocity of the Center of Pressure Displacement in all directions (Vavg or Mean Firm), (ii) the Anteroposterior (Mean-Y) and (iii) the Mediolateral (Mean-X) Centers of Pressure Displacement. The Spearman correlation coefficient was calculated to measure the correlation of the variables of balance obtained with the two different devices. RESULTS: Significant correlations were obtained when the relationships between both variables were described by fitting multiple linear regression models. There was an association between the mean velocity of center of pressure displacement in both devices, with eyes open (r = 0.21) and eyes closed (r = 0.47). In the eyes open condition, Vavg increased, on average, 0.26 units, while Mean Firm increased 1.0 unit; in the Mean-Firm; in eyes closed condition, Vavg increased, on average, 1.27 units, while Mean-Firm increased by 1,0 unit. CONCLUSION: The devices investigated presented a significant correlation for the mean velocity calculated from the total displacement of the center of pressure in all directions.Mavera Edições Técnicas e Científicas Ltda2016-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2358-04292016000200003MedicalExpress v.3 n.2 2016reponame:MedicalExpress (São Paulo. Online)instname:Mavera Edições Científicas e Técnicas Ltda-MEinstacron:METC10.5935/MedicalExpress.2016.02.03info:eu-repo/semantics/openAccessBrech,Guilherme CarlosLuna,Natália Mariana SilvaAlonso,Angélica CastilhoGreve,Júlia María D'Andréaeng2016-04-07T00:00:00Zoai:scielo:S2358-04292016000200003Revistahttp://www.medicalexpress.net.brhttps://old.scielo.br/oai/scielo-oai.php||medicalexpress@me.net.br2358-04292318-8111opendoar:2016-04-07T00:00MedicalExpress (São Paulo. Online) - Mavera Edições Científicas e Técnicas Ltda-MEfalse |
dc.title.none.fl_str_mv |
Positive correlation of postural balance evaluation by two different devices in community dwelling women |
title |
Positive correlation of postural balance evaluation by two different devices in community dwelling women |
spellingShingle |
Positive correlation of postural balance evaluation by two different devices in community dwelling women Brech,Guilherme Carlos Postural balance Center of pressure Device Force plate Postmenopausal |
title_short |
Positive correlation of postural balance evaluation by two different devices in community dwelling women |
title_full |
Positive correlation of postural balance evaluation by two different devices in community dwelling women |
title_fullStr |
Positive correlation of postural balance evaluation by two different devices in community dwelling women |
title_full_unstemmed |
Positive correlation of postural balance evaluation by two different devices in community dwelling women |
title_sort |
Positive correlation of postural balance evaluation by two different devices in community dwelling women |
author |
Brech,Guilherme Carlos |
author_facet |
Brech,Guilherme Carlos Luna,Natália Mariana Silva Alonso,Angélica Castilho Greve,Júlia María D'Andréa |
author_role |
author |
author2 |
Luna,Natália Mariana Silva Alonso,Angélica Castilho Greve,Júlia María D'Andréa |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Brech,Guilherme Carlos Luna,Natália Mariana Silva Alonso,Angélica Castilho Greve,Júlia María D'Andréa |
dc.subject.por.fl_str_mv |
Postural balance Center of pressure Device Force plate Postmenopausal |
topic |
Postural balance Center of pressure Device Force plate Postmenopausal |
description |
OBJECTIVE: To establish the convergent validity or relationship of the Balance Master® as balance assessment device by comparing its performance results with those obtained from the AccuSway Plus® force plate. METHOD: Cross-sectional observational study, without intervention, of 126 postmenopausal women (60.3 ± 3.2 years; body mass index = 27.6 ± 4.7 kg/m2). Two devices were used for the independent assessments of static balance: (a) Static postural balance assessment (posturography) was performed on a force platform (AccuSway Plus); (b) static evaluation was performed on the Balance Master®System. The variables studied in the two devices, were: (i) the Mean Velocity of the Center of Pressure Displacement in all directions (Vavg or Mean Firm), (ii) the Anteroposterior (Mean-Y) and (iii) the Mediolateral (Mean-X) Centers of Pressure Displacement. The Spearman correlation coefficient was calculated to measure the correlation of the variables of balance obtained with the two different devices. RESULTS: Significant correlations were obtained when the relationships between both variables were described by fitting multiple linear regression models. There was an association between the mean velocity of center of pressure displacement in both devices, with eyes open (r = 0.21) and eyes closed (r = 0.47). In the eyes open condition, Vavg increased, on average, 0.26 units, while Mean Firm increased 1.0 unit; in the Mean-Firm; in eyes closed condition, Vavg increased, on average, 1.27 units, while Mean-Firm increased by 1,0 unit. CONCLUSION: The devices investigated presented a significant correlation for the mean velocity calculated from the total displacement of the center of pressure in all directions. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2358-04292016000200003 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2358-04292016000200003 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/MedicalExpress.2016.02.03 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Mavera Edições Técnicas e Científicas Ltda |
publisher.none.fl_str_mv |
Mavera Edições Técnicas e Científicas Ltda |
dc.source.none.fl_str_mv |
MedicalExpress v.3 n.2 2016 reponame:MedicalExpress (São Paulo. Online) instname:Mavera Edições Científicas e Técnicas Ltda-ME instacron:METC |
instname_str |
Mavera Edições Científicas e Técnicas Ltda-ME |
instacron_str |
METC |
institution |
METC |
reponame_str |
MedicalExpress (São Paulo. Online) |
collection |
MedicalExpress (São Paulo. Online) |
repository.name.fl_str_mv |
MedicalExpress (São Paulo. Online) - Mavera Edições Científicas e Técnicas Ltda-ME |
repository.mail.fl_str_mv |
||medicalexpress@me.net.br |
_version_ |
1754734597027921920 |