Sequential hemodynamic assessment in aortic valve insufficiency in rats

Detalhes bibliográficos
Autor(a) principal: Koike,Marcia Kiyomi
Data de Publicação: 2014
Outros Autores: Matsubara,Beatriz Bojikian, Matsubara,Luiz Shiguero, Frimm,Clovis de Carvalho
Tipo de documento: Artigo
Idioma: eng
Título da fonte: MedicalExpress (São Paulo. Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2358-04292014000400214
Resumo: OBJECTIVE: In animal models of aortic insufficiency, the right common carotid artery is typically used to damage valve leaflets; this strategy impedes subsequent assessments of left ventricular hemodynamics. The present study aimed to establish an alternative technique that would allow subsequent left ventricular catheterization to monitor sequential hemodynamics in rats with aortic insufficiency. METHOD: The right internal and external carotid artery branches were dissected. The internal branch was temporarily occluded. The external branch was also occluded, and the proximal, patent segment was catheterized. Via the catheter, ventricular hemodynamic evaluations were performed before and after incurring leaflet damage. The catheter was removed, and the right external branch was permanently ligated. The temporary right internal carotid occlusion was released, and blood flow was re-established. After four weeks, left ventricular hemodynamic measurements were performed from the right common carotid artery. RESULTS: Four weeks after the establishment of aortic insufficiency, left ventricular hemodynamic parameters showed a classic chronic hemodynamic pattern, similar to that observed in patients with chronic or compensated aortic insufficiency. Systolic blood pressure was elevated and pulse pressure was increased. CONCLUSION: This new method of carotid artery catheterization permitted two sequential, distinct hemodynamic measurements, in experimental model of aortic valve insufficiency.
id METC-1_c629513a220094bc76533767c396e42b
oai_identifier_str oai:scielo:S2358-04292014000400214
network_acronym_str METC-1
network_name_str MedicalExpress (São Paulo. Online)
repository_id_str
spelling Sequential hemodynamic assessment in aortic valve insufficiency in ratsaortic insufficiencyhemodynamiccardiac remodelling OBJECTIVE: In animal models of aortic insufficiency, the right common carotid artery is typically used to damage valve leaflets; this strategy impedes subsequent assessments of left ventricular hemodynamics. The present study aimed to establish an alternative technique that would allow subsequent left ventricular catheterization to monitor sequential hemodynamics in rats with aortic insufficiency. METHOD: The right internal and external carotid artery branches were dissected. The internal branch was temporarily occluded. The external branch was also occluded, and the proximal, patent segment was catheterized. Via the catheter, ventricular hemodynamic evaluations were performed before and after incurring leaflet damage. The catheter was removed, and the right external branch was permanently ligated. The temporary right internal carotid occlusion was released, and blood flow was re-established. After four weeks, left ventricular hemodynamic measurements were performed from the right common carotid artery. RESULTS: Four weeks after the establishment of aortic insufficiency, left ventricular hemodynamic parameters showed a classic chronic hemodynamic pattern, similar to that observed in patients with chronic or compensated aortic insufficiency. Systolic blood pressure was elevated and pulse pressure was increased. CONCLUSION: This new method of carotid artery catheterization permitted two sequential, distinct hemodynamic measurements, in experimental model of aortic valve insufficiency.Mavera Edições Técnicas e Científicas Ltda2014-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2358-04292014000400214MedicalExpress v.1 n.4 2014reponame:MedicalExpress (São Paulo. Online)instname:Mavera Edições Científicas e Técnicas Ltda-MEinstacron:METC10.5935/MedicalExpress.2014.04.11info:eu-repo/semantics/openAccessKoike,Marcia KiyomiMatsubara,Beatriz BojikianMatsubara,Luiz ShigueroFrimm,Clovis de Carvalhoeng2016-05-16T00:00:00Zoai:scielo:S2358-04292014000400214Revistahttp://www.medicalexpress.net.brhttps://old.scielo.br/oai/scielo-oai.php||medicalexpress@me.net.br2358-04292318-8111opendoar:2016-05-16T00:00MedicalExpress (São Paulo. Online) - Mavera Edições Científicas e Técnicas Ltda-MEfalse
dc.title.none.fl_str_mv Sequential hemodynamic assessment in aortic valve insufficiency in rats
title Sequential hemodynamic assessment in aortic valve insufficiency in rats
spellingShingle Sequential hemodynamic assessment in aortic valve insufficiency in rats
Koike,Marcia Kiyomi
aortic insufficiency
hemodynamic
cardiac remodelling
title_short Sequential hemodynamic assessment in aortic valve insufficiency in rats
title_full Sequential hemodynamic assessment in aortic valve insufficiency in rats
title_fullStr Sequential hemodynamic assessment in aortic valve insufficiency in rats
title_full_unstemmed Sequential hemodynamic assessment in aortic valve insufficiency in rats
title_sort Sequential hemodynamic assessment in aortic valve insufficiency in rats
author Koike,Marcia Kiyomi
author_facet Koike,Marcia Kiyomi
Matsubara,Beatriz Bojikian
Matsubara,Luiz Shiguero
Frimm,Clovis de Carvalho
author_role author
author2 Matsubara,Beatriz Bojikian
Matsubara,Luiz Shiguero
Frimm,Clovis de Carvalho
author2_role author
author
author
dc.contributor.author.fl_str_mv Koike,Marcia Kiyomi
Matsubara,Beatriz Bojikian
Matsubara,Luiz Shiguero
Frimm,Clovis de Carvalho
dc.subject.por.fl_str_mv aortic insufficiency
hemodynamic
cardiac remodelling
topic aortic insufficiency
hemodynamic
cardiac remodelling
description OBJECTIVE: In animal models of aortic insufficiency, the right common carotid artery is typically used to damage valve leaflets; this strategy impedes subsequent assessments of left ventricular hemodynamics. The present study aimed to establish an alternative technique that would allow subsequent left ventricular catheterization to monitor sequential hemodynamics in rats with aortic insufficiency. METHOD: The right internal and external carotid artery branches were dissected. The internal branch was temporarily occluded. The external branch was also occluded, and the proximal, patent segment was catheterized. Via the catheter, ventricular hemodynamic evaluations were performed before and after incurring leaflet damage. The catheter was removed, and the right external branch was permanently ligated. The temporary right internal carotid occlusion was released, and blood flow was re-established. After four weeks, left ventricular hemodynamic measurements were performed from the right common carotid artery. RESULTS: Four weeks after the establishment of aortic insufficiency, left ventricular hemodynamic parameters showed a classic chronic hemodynamic pattern, similar to that observed in patients with chronic or compensated aortic insufficiency. Systolic blood pressure was elevated and pulse pressure was increased. CONCLUSION: This new method of carotid artery catheterization permitted two sequential, distinct hemodynamic measurements, in experimental model of aortic valve insufficiency.
publishDate 2014
dc.date.none.fl_str_mv 2014-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2358-04292014000400214
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2358-04292014000400214
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/MedicalExpress.2014.04.11
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Mavera Edições Técnicas e Científicas Ltda
publisher.none.fl_str_mv Mavera Edições Técnicas e Científicas Ltda
dc.source.none.fl_str_mv MedicalExpress v.1 n.4 2014
reponame:MedicalExpress (São Paulo. Online)
instname:Mavera Edições Científicas e Técnicas Ltda-ME
instacron:METC
instname_str Mavera Edições Científicas e Técnicas Ltda-ME
instacron_str METC
institution METC
reponame_str MedicalExpress (São Paulo. Online)
collection MedicalExpress (São Paulo. Online)
repository.name.fl_str_mv MedicalExpress (São Paulo. Online) - Mavera Edições Científicas e Técnicas Ltda-ME
repository.mail.fl_str_mv ||medicalexpress@me.net.br
_version_ 1754734596594860032