Análise comparativa in vitro da resistência friccional entre braquetes metálicos e estéticos

Detalhes bibliográficos
Autor(a) principal: Rodrigues, Kelly Regina Thomé Portugal
Data de Publicação: 2011
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da METODISTA
Texto Completo: http://tede.metodista.br/jspui/handle/tede/1200
Resumo: The aim of this in vitro study was to compare the friction resistance among conventional and aesthetic orthodontic brackets with metal and vitreous slot with round and rectangular wires of different sections, simulating some situations without wire displacement, 2 mm of displacement and binding of 3o. A group of 125 brackets from 5 brands (Roth Standard, Composite, Elation, Invu and Radiance) was tested, 25 brackets for each brand. Five brackets were set on a device in order to simulate a top right hemi-arch (lateral and central incisors, canine, first and second premolars) and after that, the device was coupled on an universal testing machine EMIC DL2000. The archwires 0.016 , 0.018 and 0.017 x 0.025 NiTi were used on the no displacement and 2 mm displacement tests, while the wires 0.017 x 0.025 , 0.019 x 0.025 and 0.021 x 0.025 stainless steel were used to simulate the binding effect. Variance analysis and Tukey tests (p<0,05) were run to compare brackets with different archwires sizes and angulation. The study demonstrated that the polycarbonate aesthetic bracket Composite had the least friction in all archwires sizes tested. On the other hand, the monocrystalline ceramic bracket Radiance showed the greatest frictional resistance on the tests without wire displacement. Studies with archwire displacement and binding showed a statistically significant difference between the five accessories, of which Composite, Roth Standard, Elation, Invu and Radiance produced the highest friction resistance, in increasing order. Moreover, the insertion of a metal slot in the polycarbonate bracket Elation significantly reduced the friction. However, these friction was greater than the one from a metal bracket. To sum up, the insertion of a vitreous slot in the polycrystalline ceramic bracket Invu offered a greater surface smoothness, reducing consequently the friction and favoring the displacement.
id METO_102e00955e2a18c7b4c55182d19eefd5
oai_identifier_str oai:tahbit.umesp.edu.dti:tede/1200
network_acronym_str METO
network_name_str Biblioteca Digital de Teses e Dissertações da METODISTA
repository_id_str
spelling Angelieri, FernandaCPF:23156432102http://lattes.cnpq.br/0452592229034595Scanavini, Marco AntonioCPF:35987462258http://lattes.cnpq.br/1633319072719185Miranda, André Luis Ribeiro deCPF:12345564565CPF:33068785880Rodrigues, Kelly Regina Thomé Portugal2016-08-03T16:30:57Z2011-11-212011-10-04RODRIGUES, Kelly Regina Thomé Portugal. Friction resistance among stainless steel brackets and aesthetic brackets: an in vitro study. 2011. 2 f. Dissertação (Mestrado em Ortodontia) - Universidade Metodista de São Paulo, São Bernardo do Campo, 2011.http://tede.metodista.br/jspui/handle/tede/1200The aim of this in vitro study was to compare the friction resistance among conventional and aesthetic orthodontic brackets with metal and vitreous slot with round and rectangular wires of different sections, simulating some situations without wire displacement, 2 mm of displacement and binding of 3o. A group of 125 brackets from 5 brands (Roth Standard, Composite, Elation, Invu and Radiance) was tested, 25 brackets for each brand. Five brackets were set on a device in order to simulate a top right hemi-arch (lateral and central incisors, canine, first and second premolars) and after that, the device was coupled on an universal testing machine EMIC DL2000. The archwires 0.016 , 0.018 and 0.017 x 0.025 NiTi were used on the no displacement and 2 mm displacement tests, while the wires 0.017 x 0.025 , 0.019 x 0.025 and 0.021 x 0.025 stainless steel were used to simulate the binding effect. Variance analysis and Tukey tests (p<0,05) were run to compare brackets with different archwires sizes and angulation. The study demonstrated that the polycarbonate aesthetic bracket Composite had the least friction in all archwires sizes tested. On the other hand, the monocrystalline ceramic bracket Radiance showed the greatest frictional resistance on the tests without wire displacement. Studies with archwire displacement and binding showed a statistically significant difference between the five accessories, of which Composite, Roth Standard, Elation, Invu and Radiance produced the highest friction resistance, in increasing order. Moreover, the insertion of a metal slot in the polycarbonate bracket Elation significantly reduced the friction. However, these friction was greater than the one from a metal bracket. To sum up, the insertion of a vitreous slot in the polycrystalline ceramic bracket Invu offered a greater surface smoothness, reducing consequently the friction and favoring the displacement.O presente estudo visou comparar in vitro o atrito produzido por braquetes convencionais metálicos e estéticos com canaleta metálica e vítrea quando inseridos fios de secções redonda e retangular de diferentes dimensões, simulando situações sem deslocamento, com deslocamento de 2 mm e com simulação do efeito binding 3º. Foram utilizados 125 braquetes de 5 marcas comerciais (Roth Standard, Composite, Elation, Invu e Radiance), sendo 25 braquetes para cada corpo de prova. Para os ensaios laboratoriais, foram colados 5 braquetes simulando uma hemi-arcada superior direita (incisivos central e lateral, canino, primeiro e segundo premolares) em um dispositivo para posicionamento dos braquetes, sendo este acoplado à máquina universal de ensaios EMIC DL2000. Foram empregados os fios 0,016 , 0,018 e 0,017 x 0,025 NiTi para realização dos ensaios sem deslocamento e com deslocamento de 2 mm e os fios de secção 0,017 x 0,025 , 0,019 x 0,025 e 0,021 x 0,025 CrNi para realização dos ensaios com angulação zero grau e 3º. Para a comparação entre os braquetes nos diferentes fios e angulações, foi utilizada a Análise de Variância e o teste de Tukey (p<0,05). Os resultados demonstraram que nos ensaios sem deslocamento o braquete estético de policarbonato Composite apresentou menor atrito em todos os fios avaliados, enquanto o maior atrito em todas as combinações realizadas foi observado no braquete estético cerâmico monocristalino Radiance em relação aos demais braquetes. Nos ensaios com deslocamento de 2 mm e simulação do efeito binding 3º, os resultados foram semelhantes aos observados nos ensaios sem deslocamento. Contudo, houve uma diferença estatisticamente significante entre os cinco corpos de prova, sendo o atrito verificado, respectivamente e de forma crescente, nos braquetes Composite, Roth Standard, Elation, Invu e Radiance. Pôde-se concluir que a resistência friccional teve influência da composição dos braquetes, diâmetro dos fios e tipo de ensaio realizado (deslocamento de 2 mm e angulação de 3º). Além disso, a inserção da canaleta metálica no braquete estético de policarbonato Elation reduziu de forma estatisticamente significante o atrito, porém esse foi maior do que o gerado por um braquete convencional metálico e, por fim, a incorporação da canaleta vítrea no braquete estético cerâmico policristalino Invu ofereceu uma maior lisura de superfície, reduzindo as irregularidades e imperfeições presentes na canaleta o que levou, consequentemente, a uma redução estatisticamente significante no atrito, o que demonstra que a modificação em sua canaleta favoreceu o deslocamento e reduziu de forma efetiva essa resistência à fricção.Made available in DSpace on 2016-08-03T16:30:57Z (GMT). No. of bitstreams: 1 RESUMO - Kelly Portugal Rodrigues.pdf: 90584 bytes, checksum: a9009d09309f76e094fc03b33ceabe30 (MD5) Previous issue date: 2011-10-04application/pdfhttp://tede.metodista.br/jspui/retrieve/1773/RESUMO%20-%20Kelly%20Portugal%20Rodrigues.pdf.jpgporUniversidade Metodista de São PauloPÓS GRADUAÇÃO EM ORTODONTIAUMESPBROrtodontiaFricçãoBraquetes OrtodônticosTécnica de Straight-wireFrictionOrthodontic bracketsSraight-wire techniqueCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIAAnálise comparativa in vitro da resistência friccional entre braquetes metálicos e estéticosFriction resistance among stainless steel brackets and aesthetic brackets: an in vitro studyinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da METODISTAinstname:Universidade Metodista de São Paulo (METODISTA)instacron:METODISTATHUMBNAILRESUMO - Kelly Portugal Rodrigues.pdf.jpgRESUMO - Kelly Portugal Rodrigues.pdf.jpgimage/jpeg7389http://tede.metodista.br/jspui/bitstream/tede/1200/2/RESUMO+-+Kelly+Portugal+Rodrigues.pdf.jpg40060a36ed11e31328d53c3f00b07400MD52ORIGINALRESUMO - Kelly Portugal Rodrigues.pdfapplication/pdf90584http://tede.metodista.br/jspui/bitstream/tede/1200/1/RESUMO+-+Kelly+Portugal+Rodrigues.pdfa9009d09309f76e094fc03b33ceabe30MD51tede/12002016-08-03 14:59:51.895oai:tahbit.umesp.edu.dti:tede/1200Biblioteca Digital de Teses e Dissertaçõeshttp://tede.metodista.br/jspui/http://tede.metodista.br/oai/requestbiblioteca@metodista.br||erick.roberto@metodista.bropendoar:2016-08-03T17:59:51Biblioteca Digital de Teses e Dissertações da METODISTA - Universidade Metodista de São Paulo (METODISTA)false
dc.title.por.fl_str_mv Análise comparativa in vitro da resistência friccional entre braquetes metálicos e estéticos
dc.title.alternative.eng.fl_str_mv Friction resistance among stainless steel brackets and aesthetic brackets: an in vitro study
title Análise comparativa in vitro da resistência friccional entre braquetes metálicos e estéticos
spellingShingle Análise comparativa in vitro da resistência friccional entre braquetes metálicos e estéticos
Rodrigues, Kelly Regina Thomé Portugal
Fricção
Braquetes Ortodônticos
Técnica de Straight-wire
Friction
Orthodontic brackets
Sraight-wire technique
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIA
title_short Análise comparativa in vitro da resistência friccional entre braquetes metálicos e estéticos
title_full Análise comparativa in vitro da resistência friccional entre braquetes metálicos e estéticos
title_fullStr Análise comparativa in vitro da resistência friccional entre braquetes metálicos e estéticos
title_full_unstemmed Análise comparativa in vitro da resistência friccional entre braquetes metálicos e estéticos
title_sort Análise comparativa in vitro da resistência friccional entre braquetes metálicos e estéticos
author Rodrigues, Kelly Regina Thomé Portugal
author_facet Rodrigues, Kelly Regina Thomé Portugal
author_role author
dc.contributor.advisor1.fl_str_mv Angelieri, Fernanda
dc.contributor.advisor1ID.fl_str_mv CPF:23156432102
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/0452592229034595
dc.contributor.referee1.fl_str_mv Scanavini, Marco Antonio
dc.contributor.referee1ID.fl_str_mv CPF:35987462258
dc.contributor.referee1Lattes.fl_str_mv http://lattes.cnpq.br/1633319072719185
dc.contributor.referee2.fl_str_mv Miranda, André Luis Ribeiro de
dc.contributor.referee2ID.fl_str_mv CPF:12345564565
dc.contributor.authorID.fl_str_mv CPF:33068785880
dc.contributor.author.fl_str_mv Rodrigues, Kelly Regina Thomé Portugal
contributor_str_mv Angelieri, Fernanda
Scanavini, Marco Antonio
Miranda, André Luis Ribeiro de
dc.subject.por.fl_str_mv Fricção
Braquetes Ortodônticos
Técnica de Straight-wire
topic Fricção
Braquetes Ortodônticos
Técnica de Straight-wire
Friction
Orthodontic brackets
Sraight-wire technique
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIA
dc.subject.eng.fl_str_mv Friction
Orthodontic brackets
Sraight-wire technique
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIA
description The aim of this in vitro study was to compare the friction resistance among conventional and aesthetic orthodontic brackets with metal and vitreous slot with round and rectangular wires of different sections, simulating some situations without wire displacement, 2 mm of displacement and binding of 3o. A group of 125 brackets from 5 brands (Roth Standard, Composite, Elation, Invu and Radiance) was tested, 25 brackets for each brand. Five brackets were set on a device in order to simulate a top right hemi-arch (lateral and central incisors, canine, first and second premolars) and after that, the device was coupled on an universal testing machine EMIC DL2000. The archwires 0.016 , 0.018 and 0.017 x 0.025 NiTi were used on the no displacement and 2 mm displacement tests, while the wires 0.017 x 0.025 , 0.019 x 0.025 and 0.021 x 0.025 stainless steel were used to simulate the binding effect. Variance analysis and Tukey tests (p<0,05) were run to compare brackets with different archwires sizes and angulation. The study demonstrated that the polycarbonate aesthetic bracket Composite had the least friction in all archwires sizes tested. On the other hand, the monocrystalline ceramic bracket Radiance showed the greatest frictional resistance on the tests without wire displacement. Studies with archwire displacement and binding showed a statistically significant difference between the five accessories, of which Composite, Roth Standard, Elation, Invu and Radiance produced the highest friction resistance, in increasing order. Moreover, the insertion of a metal slot in the polycarbonate bracket Elation significantly reduced the friction. However, these friction was greater than the one from a metal bracket. To sum up, the insertion of a vitreous slot in the polycrystalline ceramic bracket Invu offered a greater surface smoothness, reducing consequently the friction and favoring the displacement.
publishDate 2011
dc.date.available.fl_str_mv 2011-11-21
dc.date.issued.fl_str_mv 2011-10-04
dc.date.accessioned.fl_str_mv 2016-08-03T16:30:57Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv RODRIGUES, Kelly Regina Thomé Portugal. Friction resistance among stainless steel brackets and aesthetic brackets: an in vitro study. 2011. 2 f. Dissertação (Mestrado em Ortodontia) - Universidade Metodista de São Paulo, São Bernardo do Campo, 2011.
dc.identifier.uri.fl_str_mv http://tede.metodista.br/jspui/handle/tede/1200
identifier_str_mv RODRIGUES, Kelly Regina Thomé Portugal. Friction resistance among stainless steel brackets and aesthetic brackets: an in vitro study. 2011. 2 f. Dissertação (Mestrado em Ortodontia) - Universidade Metodista de São Paulo, São Bernardo do Campo, 2011.
url http://tede.metodista.br/jspui/handle/tede/1200
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Metodista de São Paulo
dc.publisher.program.fl_str_mv PÓS GRADUAÇÃO EM ORTODONTIA
dc.publisher.initials.fl_str_mv UMESP
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Ortodontia
publisher.none.fl_str_mv Universidade Metodista de São Paulo
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da METODISTA
instname:Universidade Metodista de São Paulo (METODISTA)
instacron:METODISTA
instname_str Universidade Metodista de São Paulo (METODISTA)
instacron_str METODISTA
institution METODISTA
reponame_str Biblioteca Digital de Teses e Dissertações da METODISTA
collection Biblioteca Digital de Teses e Dissertações da METODISTA
bitstream.url.fl_str_mv http://tede.metodista.br/jspui/bitstream/tede/1200/2/RESUMO+-+Kelly+Portugal+Rodrigues.pdf.jpg
http://tede.metodista.br/jspui/bitstream/tede/1200/1/RESUMO+-+Kelly+Portugal+Rodrigues.pdf
bitstream.checksum.fl_str_mv 40060a36ed11e31328d53c3f00b07400
a9009d09309f76e094fc03b33ceabe30
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da METODISTA - Universidade Metodista de São Paulo (METODISTA)
repository.mail.fl_str_mv biblioteca@metodista.br||erick.roberto@metodista.br
_version_ 1791079559069696000