Efeito de diferentes potências de saída de um dispositivo de fototerapia na hiperalgesia de pacientes com tendinite de calcâneo
Autor(a) principal: | |
---|---|
Data de Publicação: | 2023 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Biblioteca Digital de Teses e Dissertações da Uninove |
Texto Completo: | http://bibliotecatede.uninove.br/handle/tede/3271 |
Resumo: | The use of phototherapy has been proving to be favorable in the tendon repair process. Although several studies attest to the beneficial effect of phototherapy on tendinopathies, few study the effect of different potencies on hyperalgesia in patients with Achilles tendonitis. Therefore, this study aims to compare the effect of a single irradiation of four different powers on pain, functional capacity and inflammation in patients with Achilles tendonitis. For this purpose, a randomized, crossover, controlled and triple-blind clinical trial (therapist, patient and evaluators) was carried out, in which 7 male patients with Achilles tendinitis were recruited, randomly distributed according to the protocol order received, A, B, C or D. In all protocols, patients had the tendon in a relaxed condition, and phototherapy applications were performed with the patient lying down. Prior to the applications, the affected Achilles tendon (right or left) was marked at its midpoint and ultrasound images were acquired to measure the thickness of the tendon and the skin, tendon, and skin set. Functional capacity was assessed using the single hop test, pain was assessed using the Visual Analogue Scale (VAS) and also by algometry. Then, the patients received phototherapy with the application of the following protocols: A (657 J for 225 seconds), B (657 J for 135 seconds), C (657 J for 90 seconds) and D (18 J for 90 seconds). Application was by sweeping with continuous movement of the emitter along the tendon. The functional evaluations, through the single hop test, of pain through VAS and algometry, were performed previously, immediately, 30 minutes and 2 hours after the four phototherapy applications. Regarding pain assessment through VAS, protocol A showed a significant difference (p<0.05) when compared to protocol D, 2 hours after irradiation. The results obtained from algometry do not demonstrate statistically significant differences in the pain threshold between the tested protocols. In the assessment of tendon function using the Single Leg Hop Test, the data did not show statistical difference when comparing the different evaluation times and between the different protocols. Our results show that in a single application, protocol A with lower power and longer irradiation time proved to be effective in reducing pain in patients with Achilles tendonitis compared to the other protocols studied. |
id |
NOVE_2da15d034f903b3bd854ed21a50997f3 |
---|---|
oai_identifier_str |
oai:localhost:tede/3271 |
network_acronym_str |
NOVE |
network_name_str |
Biblioteca Digital de Teses e Dissertações da Uninove |
repository_id_str |
|
spelling |
Leal Junior, Ernesto Cesar Pintohttp://lattes.cnpq.br/8166626486201116Casalechi, Heliodora Leãohttp://lattes.cnpq.br/1635884678698403Leal Junior, Ernesto Cesar Pintohttp://lattes.cnpq.br/8166626486201116Miranda, Eduardo Foschinihttp://lattes.cnpq.br/9856878845634971Marchi, Thiago dehttp://lattes.cnpq.br/3095644960423791http://lattes.cnpq.br/7075925926909790Lino, Matheus Marinho Aguiar2023-12-06T17:08:48Z2023-06-28Lino, Matheus Marinho Aguiar. Efeito de diferentes potências de saída de um dispositivo de fototerapia na hiperalgesia de pacientes com tendinite de calcâneo. 2023. 47 f. Dissertação( Programa de Pós-Graduação em Ciências da Reabilitação) - Universidade Nove de Julho, São Paulo.http://bibliotecatede.uninove.br/handle/tede/3271The use of phototherapy has been proving to be favorable in the tendon repair process. Although several studies attest to the beneficial effect of phototherapy on tendinopathies, few study the effect of different potencies on hyperalgesia in patients with Achilles tendonitis. Therefore, this study aims to compare the effect of a single irradiation of four different powers on pain, functional capacity and inflammation in patients with Achilles tendonitis. For this purpose, a randomized, crossover, controlled and triple-blind clinical trial (therapist, patient and evaluators) was carried out, in which 7 male patients with Achilles tendinitis were recruited, randomly distributed according to the protocol order received, A, B, C or D. In all protocols, patients had the tendon in a relaxed condition, and phototherapy applications were performed with the patient lying down. Prior to the applications, the affected Achilles tendon (right or left) was marked at its midpoint and ultrasound images were acquired to measure the thickness of the tendon and the skin, tendon, and skin set. Functional capacity was assessed using the single hop test, pain was assessed using the Visual Analogue Scale (VAS) and also by algometry. Then, the patients received phototherapy with the application of the following protocols: A (657 J for 225 seconds), B (657 J for 135 seconds), C (657 J for 90 seconds) and D (18 J for 90 seconds). Application was by sweeping with continuous movement of the emitter along the tendon. The functional evaluations, through the single hop test, of pain through VAS and algometry, were performed previously, immediately, 30 minutes and 2 hours after the four phototherapy applications. Regarding pain assessment through VAS, protocol A showed a significant difference (p<0.05) when compared to protocol D, 2 hours after irradiation. The results obtained from algometry do not demonstrate statistically significant differences in the pain threshold between the tested protocols. In the assessment of tendon function using the Single Leg Hop Test, the data did not show statistical difference when comparing the different evaluation times and between the different protocols. Our results show that in a single application, protocol A with lower power and longer irradiation time proved to be effective in reducing pain in patients with Achilles tendonitis compared to the other protocols studied.A utilização da fototerapia vem se mostrando favorável no processo de reparação tendínea. Embora vários estudos atestem o efeito benéfico da fototerapia nas tendinopatias, poucos estudam o efeito de diferentes potências na hiperalgesia em pacientes com tendinite de calcâneo. Portanto, este estudo visa comparar o efeito da irradiação única de quatro diferentes potências na dor, capacidade funcional e inflamação de pacientes com tendinite de calcâneo. Para tanto, foi realizado um ensaio clínico randomizado, cruzado, controlado e triplo-cego (terapeuta, paciente e avaliadores), no qual foram recrutados 7 pacientes do sexo masculino com tendinite do calcâneo, distribuídos aleatoriamente de acordo com a ordem de protocolo recebidas, A, B C ou D. Em todos os protocolos os pacientes estavam com o tendão em condição relaxada, e as aplicações da fototerapia foram realizadas com o paciente deitado. Previamente as aplicações, o tendão calcâneo acometido (direito ou esquerdo) foi marcado em seu ponto médio e realizado a aquisição de imagens ultrassonográficas para medida da espessura do tendão e do conjunto pele, tendão, pele. A capacidade funcional foi avaliada por meio do single hop test, a dor avaliada por meio da Escala Visual Analógica (EVA) e também por algometria. Na sequência os pacientes receberam a fototerapia com a aplicação dos seguintes protocolos: A (657 J por 225 segundos), B (657 J por 135 segundos), C (657 J por 90 segundos) e D (18 J por 90 segundos). A aplicação foi por varredura com movimento contínuo do emissor ao longo do tendão. As avaliações, funcional por meio do single hop test, da dor por EVA e algometria, foram realizadas previamente, imediatamente, 30 minutos e 2 horas após as quatro aplicações da fototerapia. Em relação a avaliação da dor por meio da EVA, o protocolo A demonstrou diferença significante (p<0,05) quando comparado ao protocolo D, 2 horas após a irradiação. Os resultados obtidos a partir da algometria não demonstram diferenças estatisticamente significantes no limiar de dor entre os protocolos testados. Na avaliação da função do tendão por meio do Single Leg Hop Test, os dados não demonstraram diferença estatística na comparação dos diferentes tempos de avaliações e entre os diferentes protocolos. Nossos resultados mostram que em uma única aplicação o protocolo A de menor potência e maior tempo de irradiação se mostrou eficaz para diminuição da dor em pacientes com tendinite calcânea em comparação com os demais protocolos estudados.Submitted by Nadir Basilio (nadirsb@uninove.br) on 2023-12-06T17:08:48Z No. of bitstreams: 1 Matheus Marinho Aguiar Lino.pdf: 913681 bytes, checksum: 1faf7eb6cd08e76c06422248ca620e35 (MD5)Made available in DSpace on 2023-12-06T17:08:48Z (GMT). No. of bitstreams: 1 Matheus Marinho Aguiar Lino.pdf: 913681 bytes, checksum: 1faf7eb6cd08e76c06422248ca620e35 (MD5) Previous issue date: 2023-06-28application/pdfporUniversidade Nove de JulhoPrograma de Pós-Graduação em Ciências da ReabilitaçãoUNINOVEBrasilSaúdelaserLED (Light Emitting Diode)fototerapiatendão calcâneotendinopatialow-level laser therapyLED (Light Emitting Diode)phototherapyachilles tendontendinopathyCIENCIAS DA SAUDEEfeito de diferentes potências de saída de um dispositivo de fototerapia na hiperalgesia de pacientes com tendinite de calcâneoEffect of different output powers of a phototherapy device on hyperalgesia in patients with calcaneal tendinitis.info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis8765449414823306929600info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da Uninoveinstname:Universidade Nove de Julho (UNINOVE)instacron:UNINOVEORIGINALMatheus Marinho Aguiar Lino.pdfMatheus Marinho Aguiar Lino.pdfapplication/pdf913681http://localhost:8080/tede/bitstream/tede/3271/2/Matheus+Marinho+Aguiar+Lino.pdf1faf7eb6cd08e76c06422248ca620e35MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82165http://localhost:8080/tede/bitstream/tede/3271/1/license.txtbd3efa91386c1718a7f26a329fdcb468MD51tede/32712023-12-06 14:08:48.721oai:localhost: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Biblioteca Digital de Teses e Dissertaçõeshttp://bibliotecatede.uninove.br/PRIhttp://bibliotecatede.uninove.br/oai/requestbibliotecatede@uninove.br||bibliotecatede@uninove.bropendoar:2023-12-06T17:08:48Biblioteca Digital de Teses e Dissertações da Uninove - Universidade Nove de Julho (UNINOVE)false |
dc.title.por.fl_str_mv |
Efeito de diferentes potências de saída de um dispositivo de fototerapia na hiperalgesia de pacientes com tendinite de calcâneo |
dc.title.alternative.eng.fl_str_mv |
Effect of different output powers of a phototherapy device on hyperalgesia in patients with calcaneal tendinitis. |
title |
Efeito de diferentes potências de saída de um dispositivo de fototerapia na hiperalgesia de pacientes com tendinite de calcâneo |
spellingShingle |
Efeito de diferentes potências de saída de um dispositivo de fototerapia na hiperalgesia de pacientes com tendinite de calcâneo Lino, Matheus Marinho Aguiar laser LED (Light Emitting Diode) fototerapia tendão calcâneo tendinopatia low-level laser therapy LED (Light Emitting Diode) phototherapy achilles tendon tendinopathy CIENCIAS DA SAUDE |
title_short |
Efeito de diferentes potências de saída de um dispositivo de fototerapia na hiperalgesia de pacientes com tendinite de calcâneo |
title_full |
Efeito de diferentes potências de saída de um dispositivo de fototerapia na hiperalgesia de pacientes com tendinite de calcâneo |
title_fullStr |
Efeito de diferentes potências de saída de um dispositivo de fototerapia na hiperalgesia de pacientes com tendinite de calcâneo |
title_full_unstemmed |
Efeito de diferentes potências de saída de um dispositivo de fototerapia na hiperalgesia de pacientes com tendinite de calcâneo |
title_sort |
Efeito de diferentes potências de saída de um dispositivo de fototerapia na hiperalgesia de pacientes com tendinite de calcâneo |
author |
Lino, Matheus Marinho Aguiar |
author_facet |
Lino, Matheus Marinho Aguiar |
author_role |
author |
dc.contributor.advisor1.fl_str_mv |
Leal Junior, Ernesto Cesar Pinto |
dc.contributor.advisor1Lattes.fl_str_mv |
http://lattes.cnpq.br/8166626486201116 |
dc.contributor.advisor-co1.fl_str_mv |
Casalechi, Heliodora Leão |
dc.contributor.advisor-co1Lattes.fl_str_mv |
http://lattes.cnpq.br/1635884678698403 |
dc.contributor.referee1.fl_str_mv |
Leal Junior, Ernesto Cesar Pinto |
dc.contributor.referee1Lattes.fl_str_mv |
http://lattes.cnpq.br/8166626486201116 |
dc.contributor.referee2.fl_str_mv |
Miranda, Eduardo Foschini |
dc.contributor.referee2Lattes.fl_str_mv |
http://lattes.cnpq.br/9856878845634971 |
dc.contributor.referee3.fl_str_mv |
Marchi, Thiago de |
dc.contributor.referee3Lattes.fl_str_mv |
http://lattes.cnpq.br/3095644960423791 |
dc.contributor.authorLattes.fl_str_mv |
http://lattes.cnpq.br/7075925926909790 |
dc.contributor.author.fl_str_mv |
Lino, Matheus Marinho Aguiar |
contributor_str_mv |
Leal Junior, Ernesto Cesar Pinto Casalechi, Heliodora Leão Leal Junior, Ernesto Cesar Pinto Miranda, Eduardo Foschini Marchi, Thiago de |
dc.subject.por.fl_str_mv |
laser LED (Light Emitting Diode) fototerapia tendão calcâneo tendinopatia |
topic |
laser LED (Light Emitting Diode) fototerapia tendão calcâneo tendinopatia low-level laser therapy LED (Light Emitting Diode) phototherapy achilles tendon tendinopathy CIENCIAS DA SAUDE |
dc.subject.eng.fl_str_mv |
low-level laser therapy LED (Light Emitting Diode) phototherapy achilles tendon tendinopathy |
dc.subject.cnpq.fl_str_mv |
CIENCIAS DA SAUDE |
description |
The use of phototherapy has been proving to be favorable in the tendon repair process. Although several studies attest to the beneficial effect of phototherapy on tendinopathies, few study the effect of different potencies on hyperalgesia in patients with Achilles tendonitis. Therefore, this study aims to compare the effect of a single irradiation of four different powers on pain, functional capacity and inflammation in patients with Achilles tendonitis. For this purpose, a randomized, crossover, controlled and triple-blind clinical trial (therapist, patient and evaluators) was carried out, in which 7 male patients with Achilles tendinitis were recruited, randomly distributed according to the protocol order received, A, B, C or D. In all protocols, patients had the tendon in a relaxed condition, and phototherapy applications were performed with the patient lying down. Prior to the applications, the affected Achilles tendon (right or left) was marked at its midpoint and ultrasound images were acquired to measure the thickness of the tendon and the skin, tendon, and skin set. Functional capacity was assessed using the single hop test, pain was assessed using the Visual Analogue Scale (VAS) and also by algometry. Then, the patients received phototherapy with the application of the following protocols: A (657 J for 225 seconds), B (657 J for 135 seconds), C (657 J for 90 seconds) and D (18 J for 90 seconds). Application was by sweeping with continuous movement of the emitter along the tendon. The functional evaluations, through the single hop test, of pain through VAS and algometry, were performed previously, immediately, 30 minutes and 2 hours after the four phototherapy applications. Regarding pain assessment through VAS, protocol A showed a significant difference (p<0.05) when compared to protocol D, 2 hours after irradiation. The results obtained from algometry do not demonstrate statistically significant differences in the pain threshold between the tested protocols. In the assessment of tendon function using the Single Leg Hop Test, the data did not show statistical difference when comparing the different evaluation times and between the different protocols. Our results show that in a single application, protocol A with lower power and longer irradiation time proved to be effective in reducing pain in patients with Achilles tendonitis compared to the other protocols studied. |
publishDate |
2023 |
dc.date.accessioned.fl_str_mv |
2023-12-06T17:08:48Z |
dc.date.issued.fl_str_mv |
2023-06-28 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
Lino, Matheus Marinho Aguiar. Efeito de diferentes potências de saída de um dispositivo de fototerapia na hiperalgesia de pacientes com tendinite de calcâneo. 2023. 47 f. Dissertação( Programa de Pós-Graduação em Ciências da Reabilitação) - Universidade Nove de Julho, São Paulo. |
dc.identifier.uri.fl_str_mv |
http://bibliotecatede.uninove.br/handle/tede/3271 |
identifier_str_mv |
Lino, Matheus Marinho Aguiar. Efeito de diferentes potências de saída de um dispositivo de fototerapia na hiperalgesia de pacientes com tendinite de calcâneo. 2023. 47 f. Dissertação( Programa de Pós-Graduação em Ciências da Reabilitação) - Universidade Nove de Julho, São Paulo. |
url |
http://bibliotecatede.uninove.br/handle/tede/3271 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.cnpq.fl_str_mv |
8765449414823306929 |
dc.relation.confidence.fl_str_mv |
600 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Nove de Julho |
dc.publisher.program.fl_str_mv |
Programa de Pós-Graduação em Ciências da Reabilitação |
dc.publisher.initials.fl_str_mv |
UNINOVE |
dc.publisher.country.fl_str_mv |
Brasil |
dc.publisher.department.fl_str_mv |
Saúde |
publisher.none.fl_str_mv |
Universidade Nove de Julho |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da Uninove instname:Universidade Nove de Julho (UNINOVE) instacron:UNINOVE |
instname_str |
Universidade Nove de Julho (UNINOVE) |
instacron_str |
UNINOVE |
institution |
UNINOVE |
reponame_str |
Biblioteca Digital de Teses e Dissertações da Uninove |
collection |
Biblioteca Digital de Teses e Dissertações da Uninove |
bitstream.url.fl_str_mv |
http://localhost:8080/tede/bitstream/tede/3271/2/Matheus+Marinho+Aguiar+Lino.pdf http://localhost:8080/tede/bitstream/tede/3271/1/license.txt |
bitstream.checksum.fl_str_mv |
1faf7eb6cd08e76c06422248ca620e35 bd3efa91386c1718a7f26a329fdcb468 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações da Uninove - Universidade Nove de Julho (UNINOVE) |
repository.mail.fl_str_mv |
bibliotecatede@uninove.br||bibliotecatede@uninove.br |
_version_ |
1811016891054948352 |