Análise de tensões em prótese fixa total implantossuportada em função da aplicação de resina acrílica termopolimerizável e do número de pilares

Detalhes bibliográficos
Autor(a) principal: Lobato, Marina Rechden
Data de Publicação: 2009
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional PUCRS
Texto Completo: http://hdl.handle.net/10923/455
Resumo: The achievement of passive fit of the metal framework results from a meticulous process including clinical and laboratorial procedures. One of the main causes of laboratory distortions is the application of the aesthetic veneering material. The purpose of this study was to evaluate the distribution of tensions on abutments of implant-supported fixed total prosthesis. The effect of the veneering material (acrylic resin) and number of abutments (five or four) was investigated. Four metallic bars cast in Palladium-Silver alloy were fabricated to simulate implant-supported fixed total prosthesis on five dental implants. Strain gauges were fixed on the abutments to measure the tension before and after the application of the veneering material (n=4). The values of tension were measured in two situations: over five or four abutments in the master model. The tension data had a normal distribution and were analyzed by using Two-Way Analysis of Variance. No statistically significant difference was found as a function of the main factors (veneering material P=0.172; number of abutments P=0.523) or the interaction of main factors (P=0.604). The results of this study suggest that the application of acrylic resin veneering do not increase the tension in abutments. In this in vitro study, there was no significant difference between the values of tension in the model with five and four abutments.
id PUCR_68c269aa688d81063ec48a9cbc42d2a5
oai_identifier_str oai:repositorio.pucrs.br:10923/455
network_acronym_str PUCR
network_name_str Repositório Institucional PUCRS
repository_id_str
spelling Lobato, Marina RechdenShinkai, Rosemary Sadami Arai2011-12-27T14:14:17Z2011-12-27T14:14:17Z2009http://hdl.handle.net/10923/455The achievement of passive fit of the metal framework results from a meticulous process including clinical and laboratorial procedures. One of the main causes of laboratory distortions is the application of the aesthetic veneering material. The purpose of this study was to evaluate the distribution of tensions on abutments of implant-supported fixed total prosthesis. The effect of the veneering material (acrylic resin) and number of abutments (five or four) was investigated. Four metallic bars cast in Palladium-Silver alloy were fabricated to simulate implant-supported fixed total prosthesis on five dental implants. Strain gauges were fixed on the abutments to measure the tension before and after the application of the veneering material (n=4). The values of tension were measured in two situations: over five or four abutments in the master model. The tension data had a normal distribution and were analyzed by using Two-Way Analysis of Variance. No statistically significant difference was found as a function of the main factors (veneering material P=0.172; number of abutments P=0.523) or the interaction of main factors (P=0.604). The results of this study suggest that the application of acrylic resin veneering do not increase the tension in abutments. In this in vitro study, there was no significant difference between the values of tension in the model with five and four abutments.A obtenção da passividade da estrutura metálica é resultado de um processo meticuloso que inclui procedimentos clínicos e laboratoriais. Um dos principais procedimentos laboratoriais causadores de distorções é a aplicação do revestimento estético. Este estudo teve como objetivo avaliar, com utilização de extensômetros, a distribuição das tensões geradas nos pilares protéticos de próteses totais fixas implantossuportadas, em função do tipo de revestimento estético (resina acrílica termopolimerizável) e do número de pilares (cinco e quatro pilares). Quatro barras metálicas em liga Prata-Paládio simularam próteses fixas tipo Protocolo Bränemark sobre cinco implantes. Extensômetros foram colados nos pilares protéticos do modelo-mestre para medir a deformação antes (n=4 barras sem revestimento) e após a aplicação da resina acrílica termopolimerizável (Artigos Odontológicos Clássico, São Paulo, Brasil) (n=4 barras com resina). Os valores de tensão foram medidos com arranjo de cinco e de quatro pilares protéticos no modelo-mestre. Os dados de tensão seguiram uma distribuição normal. As médias de tensão foram submetidas à Análise de Variância de Dois Fatores. Não foi encontrada diferença estatisticamente significativa entre os fatores de variação (aplicação do revestimento P=0,172; e número de pilar P=0,523) e a interação entre os fatores (P=0,604).Os resultados deste estudo sugerem que, nesta simulação de próteses do tipo protocolo Bränemark, a aplicação do revestimento de resina acrílica termopolimerizável não gerou variação significativa de tensão nos pilares. Neste modelo experimental, o número de pilares (quatro ou cinco) não afetou a tensão no sistema, com ou sem revestimento de resina acrílica.Made available in DSpace on 2011-12-27T14:14:17Z (GMT). No. of bitstreams: 2 000423388-0.pdf: 875648 bytes, checksum: 6fa78c7588ba9b868b083818569e93a7 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5)Pontifícia Universidade Católica do Rio Grande do SulPorto AlegreODONTOLOGIAPRÓTESE DENTÁRIAIMPLANTODONTIARESINAS ACRÍLICASBIOMECÂNICAAnálise de tensões em prótese fixa total implantossuportada em função da aplicação de resina acrílica termopolimerizável e do número de pilaresinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisPontifícia Universidade Católica do Rio Grande do SulFaculdade de OdontologiaPrograma de Pós-Graduação em OdontologiaMestrado2009porreponame:Repositório Institucional PUCRSinstname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSinfo:eu-repo/semantics/openAccessORIGINAL000423388-0.pdfTexto Completoapplication/pdf875648repositorio.pucrs.br/jspui/bitstream/10923/455/1/000423388-0.pdf6fa78c7588ba9b868b083818569e93a7MD51LICENSElicense.txttext/plain581repositorio.pucrs.br/jspui/bitstream/10923/455/2/license.txt44ea52f0b7567232681c6e3d72285adcMD52TEXT000423388-0.pdf.txt000423388-0.pdf.txtExtracted texttext/plain74172repositorio.pucrs.br/jspui/bitstream/10923/455/3/000423388-0.pdf.txtaa7e6e6a3290e963431c03aaf71f9f95MD5310923/4552017-09-28 11:05:34.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ório InstitucionalPRI
dc.title.pt_BR.fl_str_mv Análise de tensões em prótese fixa total implantossuportada em função da aplicação de resina acrílica termopolimerizável e do número de pilares
title Análise de tensões em prótese fixa total implantossuportada em função da aplicação de resina acrílica termopolimerizável e do número de pilares
spellingShingle Análise de tensões em prótese fixa total implantossuportada em função da aplicação de resina acrílica termopolimerizável e do número de pilares
Lobato, Marina Rechden
ODONTOLOGIA
PRÓTESE DENTÁRIA
IMPLANTODONTIA
RESINAS ACRÍLICAS
BIOMECÂNICA
title_short Análise de tensões em prótese fixa total implantossuportada em função da aplicação de resina acrílica termopolimerizável e do número de pilares
title_full Análise de tensões em prótese fixa total implantossuportada em função da aplicação de resina acrílica termopolimerizável e do número de pilares
title_fullStr Análise de tensões em prótese fixa total implantossuportada em função da aplicação de resina acrílica termopolimerizável e do número de pilares
title_full_unstemmed Análise de tensões em prótese fixa total implantossuportada em função da aplicação de resina acrílica termopolimerizável e do número de pilares
title_sort Análise de tensões em prótese fixa total implantossuportada em função da aplicação de resina acrílica termopolimerizável e do número de pilares
author Lobato, Marina Rechden
author_facet Lobato, Marina Rechden
author_role author
dc.contributor.author.fl_str_mv Lobato, Marina Rechden
dc.contributor.advisor1.fl_str_mv Shinkai, Rosemary Sadami Arai
contributor_str_mv Shinkai, Rosemary Sadami Arai
dc.subject.por.fl_str_mv ODONTOLOGIA
PRÓTESE DENTÁRIA
IMPLANTODONTIA
RESINAS ACRÍLICAS
BIOMECÂNICA
topic ODONTOLOGIA
PRÓTESE DENTÁRIA
IMPLANTODONTIA
RESINAS ACRÍLICAS
BIOMECÂNICA
description The achievement of passive fit of the metal framework results from a meticulous process including clinical and laboratorial procedures. One of the main causes of laboratory distortions is the application of the aesthetic veneering material. The purpose of this study was to evaluate the distribution of tensions on abutments of implant-supported fixed total prosthesis. The effect of the veneering material (acrylic resin) and number of abutments (five or four) was investigated. Four metallic bars cast in Palladium-Silver alloy were fabricated to simulate implant-supported fixed total prosthesis on five dental implants. Strain gauges were fixed on the abutments to measure the tension before and after the application of the veneering material (n=4). The values of tension were measured in two situations: over five or four abutments in the master model. The tension data had a normal distribution and were analyzed by using Two-Way Analysis of Variance. No statistically significant difference was found as a function of the main factors (veneering material P=0.172; number of abutments P=0.523) or the interaction of main factors (P=0.604). The results of this study suggest that the application of acrylic resin veneering do not increase the tension in abutments. In this in vitro study, there was no significant difference between the values of tension in the model with five and four abutments.
publishDate 2009
dc.date.issued.fl_str_mv 2009
dc.date.accessioned.fl_str_mv 2011-12-27T14:14:17Z
dc.date.available.fl_str_mv 2011-12-27T14:14:17Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10923/455
url http://hdl.handle.net/10923/455
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
Porto Alegre
publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
Porto Alegre
dc.source.none.fl_str_mv reponame:Repositório Institucional PUCRS
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Repositório Institucional PUCRS
collection Repositório Institucional PUCRS
bitstream.url.fl_str_mv repositorio.pucrs.br/jspui/bitstream/10923/455/1/000423388-0.pdf
repositorio.pucrs.br/jspui/bitstream/10923/455/2/license.txt
repositorio.pucrs.br/jspui/bitstream/10923/455/3/000423388-0.pdf.txt
bitstream.checksum.fl_str_mv 6fa78c7588ba9b868b083818569e93a7
44ea52f0b7567232681c6e3d72285adc
aa7e6e6a3290e963431c03aaf71f9f95
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1731736511874859008