DEPLOYMENT OF METHOD FOR ANALYSIS OF STABLE CARBON ISOTOPES (N-ALKANES C1-C5) IN GAS SAMPLES AT LOW CONCENTRATIONS

Detalhes bibliográficos
Autor(a) principal: LAURA JULIANA ROZO MORALES
Data de Publicação: 2011
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da PUC-RIO (Projeto Maxwell)
Texto Completo: https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=19631@1
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=19631@2
Resumo: A concentração e composição isotópica Delta13C dos n-alcanos C1-C5, tem-se mostrado como uma ferramenta poderosa na interpretação de processos de interesse nas áreas de exploração de hidrocarbonetos, estudo de mudanças climáticas, biodegradação de óleos e elucidação do ciclo global de carbono. Neste contexto, os estudos sobre análise de metano (C1) tem-se destacado e multiplicado devido à importância do C1 na indústria energética e ao potencial do C1 como gás de efeito estufa. A análise de amostras atmosféricas e de origem geológica é um desafio, já que a baixa concentração limita o uso da técnica CG-EMRI (Cromatografía Gasosa acoplada à Espectrometria de Massas de Razão Isotópica) e obriga à utilização de elevado volume de amostra. Técnicas criogênicas de pré-concentração acopladas ao sistema CG-EMRI tem sido testadas com sucesso na análise de gases como dióxido de carbono (CO2), óxido nitroso (N2O), metano (CH4) e monóxido de carbono (CO). Neste estudo foi testado o uso de um dispositivo de concentração criogênica de gases (PreCon da Thermo Scientific), desenvolvido para análise de CH4 e N2O atmosféricos, na determinação da composição isotópica Delta13C dos n-alcanos C1-C5 (metano, etano, propano, iso-butano, n-butano, iso-pentano e n-pentano) em amostras gasosas. O dispositivo pré-concentrador permite, usando-se somente alguns mililitros de amostra, a coleta dos gases condensáveis (C2mais, CO2, Ar, N2, O2, N2O, H2O) em nitrogênio líquido (N2(l)), enquanto o metano (C1) é oxidado, crio-focalizado (como CO2) e injetado no sistema de CG-EMRI acoplado. Já que o dispositivo não oxida seletivamente os compostos introduzidos, é necessário realizar a combustão dos analitos fora do pré-concentrador após a separação cromatográfica. Esta limitante do equipamento representou o maior desafio no desenvolvimento da metodologia analítica. A pré-concentração e liberação dos gases analitos foram testadas mediante a avaliação da razão isotópica de padrões diluídos (no PreCon) e concentrados no sistema de CG-EMRI. Inicialmente, foi ajustada a análise dos n-alcanos C1-C5 usando a técnica convencional CG-EMRI (precisão analítica menor que 0.2 por cento) e posteriormente verificou-se a ausência de fracionamento durante a análise feita no dispositivo de pré-concentração criogênica (precisão analítica menor que 0.5 por cento). A liberação e determinação dos C2mais foram feitas via oxidação no sistema de CG-EMRI, confirmando a presença de uma interferência na análise do n-C4. Para garantir a oxidação seletiva do C1, foram testadas diferentes modificações nas armadilhas e na programação analítica. A introdução de coluna tipo PLOT (Porous Layer Open Tubular) nas armadilhas do equipamento e o uso de diferentes temperaturas criogênicas permitiram verificar a coleta quantitativa dos gases, a separação do metano dos C2mais e a diminuição de algumas interferências que podem ser coletadas em nitrogênio líquido (N2 e O2). Igualmente, as interferências da água, CO2, N2 e O2 e olefinas foram minimizadas pela introdução de uma armadilha de limpeza do gás de arraste. A metodologia desenvolvida foi testada mediante a análise do headspace de sete sedimentos que apresentaram baixas concentrações de C2-C4 na determinação por CG-DIC-DCT (Cromatografia Gasosa com Detector de Ionização de Chama e Detector de Condutividade Térmica). Igualmente foi analisada uma amostra de gás confinado em um amostrador especial tipo Isotube. A determinação da composição isotópica destas amostras confirmou a aplicabilidade da metodologia e do sistema. Nas amostras de menor concentração, o metano foi oxidado no PreCon e os C2-C4 foram coletados no dispositivo de pré-concentração para posterior oxidação no sistema de CG-EMRI. Devido ao uso de dois fornos de combustão, a análise de metano apresentou maior variabilidade ( mais ou menos 2 por cento) e as tentativas de focalizar e oxidar o metano no forno do sistema de CG-EMRI foram pouco satisfatórias devido à co-eluição. Mediante a coluna PLOT inserida no dispositivo de pré-concentração foi possível coletar o metano, no entanto, a focalização foi pouco eficiente e o sinal do CO2 (do metano oxidado) apresentou interferentes não identificados. Assim, para facilitar e garantir a análise simultânea dos C1-C5, ainda é necessária a instalação de uma válvula que isole o reator do PreCon e permita a passagem direta dos C2mais até o sistema de focalização.
id PUC_RIO-1_11704916aa22f6ada84a548c9876abd3
oai_identifier_str oai:MAXWELL.puc-rio.br:19631
network_acronym_str PUC_RIO-1
network_name_str Repositório Institucional da PUC-RIO (Projeto Maxwell)
repository_id_str 534
spelling info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisDEPLOYMENT OF METHOD FOR ANALYSIS OF STABLE CARBON ISOTOPES (N-ALKANES C1-C5) IN GAS SAMPLES AT LOW CONCENTRATIONS IMPLANTAÇÃO DE MÉTODO PARA ANÁLISE DE ISÓTOPOS ESTÁVEIS DE CARBONO (N-ALCANOS C1-C5) EM GASES A BAIXAS CONCENTRAÇÕES 2011-10-06ANGELA DE LUCA REBELLO WAGENER21860530710lattes.cnpq.br/9452001683934684ANGELA DE LUCA REBELLO WAGENERARTHUR DE LEMOS SCOFIELDARTHUR DE LEMOS SCOFIELDAIDA PEREIRA BAETAAIDA PEREIRA BAETA06061368780LAURA JULIANA ROZO MORALESPONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIROPPG EM QUÍMICAPUC-RioBRA concentração e composição isotópica Delta13C dos n-alcanos C1-C5, tem-se mostrado como uma ferramenta poderosa na interpretação de processos de interesse nas áreas de exploração de hidrocarbonetos, estudo de mudanças climáticas, biodegradação de óleos e elucidação do ciclo global de carbono. Neste contexto, os estudos sobre análise de metano (C1) tem-se destacado e multiplicado devido à importância do C1 na indústria energética e ao potencial do C1 como gás de efeito estufa. A análise de amostras atmosféricas e de origem geológica é um desafio, já que a baixa concentração limita o uso da técnica CG-EMRI (Cromatografía Gasosa acoplada à Espectrometria de Massas de Razão Isotópica) e obriga à utilização de elevado volume de amostra. Técnicas criogênicas de pré-concentração acopladas ao sistema CG-EMRI tem sido testadas com sucesso na análise de gases como dióxido de carbono (CO2), óxido nitroso (N2O), metano (CH4) e monóxido de carbono (CO). Neste estudo foi testado o uso de um dispositivo de concentração criogênica de gases (PreCon da Thermo Scientific), desenvolvido para análise de CH4 e N2O atmosféricos, na determinação da composição isotópica Delta13C dos n-alcanos C1-C5 (metano, etano, propano, iso-butano, n-butano, iso-pentano e n-pentano) em amostras gasosas. O dispositivo pré-concentrador permite, usando-se somente alguns mililitros de amostra, a coleta dos gases condensáveis (C2mais, CO2, Ar, N2, O2, N2O, H2O) em nitrogênio líquido (N2(l)), enquanto o metano (C1) é oxidado, crio-focalizado (como CO2) e injetado no sistema de CG-EMRI acoplado. Já que o dispositivo não oxida seletivamente os compostos introduzidos, é necessário realizar a combustão dos analitos fora do pré-concentrador após a separação cromatográfica. Esta limitante do equipamento representou o maior desafio no desenvolvimento da metodologia analítica. A pré-concentração e liberação dos gases analitos foram testadas mediante a avaliação da razão isotópica de padrões diluídos (no PreCon) e concentrados no sistema de CG-EMRI. Inicialmente, foi ajustada a análise dos n-alcanos C1-C5 usando a técnica convencional CG-EMRI (precisão analítica menor que 0.2 por cento) e posteriormente verificou-se a ausência de fracionamento durante a análise feita no dispositivo de pré-concentração criogênica (precisão analítica menor que 0.5 por cento). A liberação e determinação dos C2mais foram feitas via oxidação no sistema de CG-EMRI, confirmando a presença de uma interferência na análise do n-C4. Para garantir a oxidação seletiva do C1, foram testadas diferentes modificações nas armadilhas e na programação analítica. A introdução de coluna tipo PLOT (Porous Layer Open Tubular) nas armadilhas do equipamento e o uso de diferentes temperaturas criogênicas permitiram verificar a coleta quantitativa dos gases, a separação do metano dos C2mais e a diminuição de algumas interferências que podem ser coletadas em nitrogênio líquido (N2 e O2). Igualmente, as interferências da água, CO2, N2 e O2 e olefinas foram minimizadas pela introdução de uma armadilha de limpeza do gás de arraste. A metodologia desenvolvida foi testada mediante a análise do headspace de sete sedimentos que apresentaram baixas concentrações de C2-C4 na determinação por CG-DIC-DCT (Cromatografia Gasosa com Detector de Ionização de Chama e Detector de Condutividade Térmica). Igualmente foi analisada uma amostra de gás confinado em um amostrador especial tipo Isotube. A determinação da composição isotópica destas amostras confirmou a aplicabilidade da metodologia e do sistema. Nas amostras de menor concentração, o metano foi oxidado no PreCon e os C2-C4 foram coletados no dispositivo de pré-concentração para posterior oxidação no sistema de CG-EMRI. Devido ao uso de dois fornos de combustão, a análise de metano apresentou maior variabilidade ( mais ou menos 2 por cento) e as tentativas de focalizar e oxidar o metano no forno do sistema de CG-EMRI foram pouco satisfatórias devido à co-eluição. Mediante a coluna PLOT inserida no dispositivo de pré-concentração foi possível coletar o metano, no entanto, a focalização foi pouco eficiente e o sinal do CO2 (do metano oxidado) apresentou interferentes não identificados. Assim, para facilitar e garantir a análise simultânea dos C1-C5, ainda é necessária a instalação de uma válvula que isole o reator do PreCon e permita a passagem direta dos C2mais até o sistema de focalização.The concentration and isotopic composition of n-alkanes C1-C5 has revealed as a powerful tool for interpretation of interesting processes in the oil exploration industry, studies of global climate change, oil biodegradation and carbon cycle elucidation. In this context, studies about methane analysis have been distinguished and multiplied due to the important role of C1 in the energy industry and its contribution for the greenhouse effect. The analysis of atmospheric and geological samples is a challenge, since the low concentration limits the use of the conventional GC-IRMS technique (Gas Chromatography coupled online with Isotopic Ratio Mass Spectrometry) and requires the use a large sample volume. Preconcentration techniques coupled to GC-IRMS systems have been successfully tested in gas analysis such as carbon dioxide (CO2), nitrous oxide (N2O), methane (CH4), and carbon monoxide (CO). In this study was tested the use of a gas preconcentration device (PreCon, Thermo Scientific), developed to determinate methane and nitrous oxide at atmospheric concentrations, in the determination of carbon isotope ratio of n-alkanes C1-C5 (methane, ethane, propane, iso-butane, n-butane, iso-pentane e n-pentane) in gas samples. The preconcentration device allows, using a few milliliters of sample, the trapping of condensable gases (C2plus, CO2, Ar, N2, O2, N2O, H2O) at low temperature (in liquid N2), while methane is oxidized, cryo-focused (as CO2) and injected in the GC-IRMS system coupled. However the equipment does not oxidize selectively the introduced compounds, it is necessary to carry out the combustion outside of preconcentrator after a chromatographic separation. This limiting represented the biggest challenge in the development of analytical methodology. The preconcentration and release of analytes were tested by evaluation of diluted standards (in PreCon) and concentrated standards in GC-IRMS system. Initially, the analyses of C1-C5 at high concentration was adjusted in the GC-IRMS system (analytical precision less than 0.2 per cent) and later was verified no fractionation due to PreCon device (analytical precision less than 0.5 per cent). The release and determination of C2plus were made by oxidation in the GC-IRMS system and was confirmed a presence of some interference in the analyses of n-butane. To ensure the selective oxidation of C1, there were tested a few modifications in the cryogenic traps and in the analytical method. The introduction of PLOT column in the traps, and the use of others cryogenic temperatures allowed to verify the quantitative collection of gas, the separation of non methane hydrocarbons and the decrease of interferences collected in liquid nitrogen (N2 and O2). Also, interferences like water, CO2, N2, O2 and olefins were minimized by introduction of a cleaning trap for the carrier gas. The developed methodology was tested analyzing the headspace of sediments that had low concentration of C2-C5 by GC-FID-TCD (Gas Chromatography with Flame ionization detector and thermal conductivity detector). Also, it was analyzed a sample of confined gas in a Isotube device. The determination of isotopic composition in these samples confirmed the applicability of methodology and system proposed. In samples with low concentration of n-alcanes, the methane was oxidized using the PreCon reator and the C2plus were concentrated using the PreCon but the oxidation was done in the GC-IRMS system. Because the reason of use two combustion reactors, the methane analysis showed high variability (more or less 2 per cent) and attempts to cryo-focus and oxidize methane in the GC-IRMS system were unsatisfactory due to co-elution. Through a PLOT column added in the preconcentration device was possible to collect the methane, however, the cryo-focusing was ineffective and the CO2 signal (product of methane oxidized) showed no identified interferences. Thus, to facilitate and ensure the simultaneous analysis of n-alcanes C1-C5, it is still necessary to install a valve to isolate the PreCon reactor allowing the direct pass of C2plus to cryo-focusing system.COORDENAÇÃO DE APERFEIÇOAMENTO DO PESSOAL DE ENSINO SUPERIORPROGRAMA DE SUPORTE À PÓS-GRADUAÇÃO DE INSTS. DE ENSINOhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=19631@1https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=19631@2porreponame:Repositório Institucional da PUC-RIO (Projeto Maxwell)instname:Pontifícia Universidade Católica do Rio de Janeiro (PUC-RIO)instacron:PUC_RIOinfo:eu-repo/semantics/openAccess2022-11-01T13:16:01Zoai:MAXWELL.puc-rio.br:19631Repositório InstitucionalPRIhttps://www.maxwell.vrac.puc-rio.br/ibict.phpopendoar:5342018-08-10T00:00Repositório Institucional da PUC-RIO (Projeto Maxwell) - Pontifícia Universidade Católica do Rio de Janeiro (PUC-RIO)false
dc.title.en.fl_str_mv DEPLOYMENT OF METHOD FOR ANALYSIS OF STABLE CARBON ISOTOPES (N-ALKANES C1-C5) IN GAS SAMPLES AT LOW CONCENTRATIONS
dc.title.alternative.pt.fl_str_mv IMPLANTAÇÃO DE MÉTODO PARA ANÁLISE DE ISÓTOPOS ESTÁVEIS DE CARBONO (N-ALCANOS C1-C5) EM GASES A BAIXAS CONCENTRAÇÕES
title DEPLOYMENT OF METHOD FOR ANALYSIS OF STABLE CARBON ISOTOPES (N-ALKANES C1-C5) IN GAS SAMPLES AT LOW CONCENTRATIONS
spellingShingle DEPLOYMENT OF METHOD FOR ANALYSIS OF STABLE CARBON ISOTOPES (N-ALKANES C1-C5) IN GAS SAMPLES AT LOW CONCENTRATIONS
LAURA JULIANA ROZO MORALES
title_short DEPLOYMENT OF METHOD FOR ANALYSIS OF STABLE CARBON ISOTOPES (N-ALKANES C1-C5) IN GAS SAMPLES AT LOW CONCENTRATIONS
title_full DEPLOYMENT OF METHOD FOR ANALYSIS OF STABLE CARBON ISOTOPES (N-ALKANES C1-C5) IN GAS SAMPLES AT LOW CONCENTRATIONS
title_fullStr DEPLOYMENT OF METHOD FOR ANALYSIS OF STABLE CARBON ISOTOPES (N-ALKANES C1-C5) IN GAS SAMPLES AT LOW CONCENTRATIONS
title_full_unstemmed DEPLOYMENT OF METHOD FOR ANALYSIS OF STABLE CARBON ISOTOPES (N-ALKANES C1-C5) IN GAS SAMPLES AT LOW CONCENTRATIONS
title_sort DEPLOYMENT OF METHOD FOR ANALYSIS OF STABLE CARBON ISOTOPES (N-ALKANES C1-C5) IN GAS SAMPLES AT LOW CONCENTRATIONS
dc.creator.Lattes.none.fl_str_mv
author LAURA JULIANA ROZO MORALES
author_facet LAURA JULIANA ROZO MORALES
author_role author
dc.contributor.advisor1.fl_str_mv ANGELA DE LUCA REBELLO WAGENER
dc.contributor.advisor1ID.fl_str_mv 21860530710
dc.contributor.advisor1Lattes.fl_str_mv lattes.cnpq.br/9452001683934684
dc.contributor.referee1.fl_str_mv ANGELA DE LUCA REBELLO WAGENER
dc.contributor.referee2.fl_str_mv ARTHUR DE LEMOS SCOFIELD
dc.contributor.referee3.fl_str_mv ARTHUR DE LEMOS SCOFIELD
dc.contributor.referee4.fl_str_mv AIDA PEREIRA BAETA
dc.contributor.referee5.fl_str_mv AIDA PEREIRA BAETA
dc.contributor.authorID.fl_str_mv 06061368780
dc.contributor.author.fl_str_mv LAURA JULIANA ROZO MORALES
contributor_str_mv ANGELA DE LUCA REBELLO WAGENER
ANGELA DE LUCA REBELLO WAGENER
ARTHUR DE LEMOS SCOFIELD
ARTHUR DE LEMOS SCOFIELD
AIDA PEREIRA BAETA
AIDA PEREIRA BAETA
description A concentração e composição isotópica Delta13C dos n-alcanos C1-C5, tem-se mostrado como uma ferramenta poderosa na interpretação de processos de interesse nas áreas de exploração de hidrocarbonetos, estudo de mudanças climáticas, biodegradação de óleos e elucidação do ciclo global de carbono. Neste contexto, os estudos sobre análise de metano (C1) tem-se destacado e multiplicado devido à importância do C1 na indústria energética e ao potencial do C1 como gás de efeito estufa. A análise de amostras atmosféricas e de origem geológica é um desafio, já que a baixa concentração limita o uso da técnica CG-EMRI (Cromatografía Gasosa acoplada à Espectrometria de Massas de Razão Isotópica) e obriga à utilização de elevado volume de amostra. Técnicas criogênicas de pré-concentração acopladas ao sistema CG-EMRI tem sido testadas com sucesso na análise de gases como dióxido de carbono (CO2), óxido nitroso (N2O), metano (CH4) e monóxido de carbono (CO). Neste estudo foi testado o uso de um dispositivo de concentração criogênica de gases (PreCon da Thermo Scientific), desenvolvido para análise de CH4 e N2O atmosféricos, na determinação da composição isotópica Delta13C dos n-alcanos C1-C5 (metano, etano, propano, iso-butano, n-butano, iso-pentano e n-pentano) em amostras gasosas. O dispositivo pré-concentrador permite, usando-se somente alguns mililitros de amostra, a coleta dos gases condensáveis (C2mais, CO2, Ar, N2, O2, N2O, H2O) em nitrogênio líquido (N2(l)), enquanto o metano (C1) é oxidado, crio-focalizado (como CO2) e injetado no sistema de CG-EMRI acoplado. Já que o dispositivo não oxida seletivamente os compostos introduzidos, é necessário realizar a combustão dos analitos fora do pré-concentrador após a separação cromatográfica. Esta limitante do equipamento representou o maior desafio no desenvolvimento da metodologia analítica. A pré-concentração e liberação dos gases analitos foram testadas mediante a avaliação da razão isotópica de padrões diluídos (no PreCon) e concentrados no sistema de CG-EMRI. Inicialmente, foi ajustada a análise dos n-alcanos C1-C5 usando a técnica convencional CG-EMRI (precisão analítica menor que 0.2 por cento) e posteriormente verificou-se a ausência de fracionamento durante a análise feita no dispositivo de pré-concentração criogênica (precisão analítica menor que 0.5 por cento). A liberação e determinação dos C2mais foram feitas via oxidação no sistema de CG-EMRI, confirmando a presença de uma interferência na análise do n-C4. Para garantir a oxidação seletiva do C1, foram testadas diferentes modificações nas armadilhas e na programação analítica. A introdução de coluna tipo PLOT (Porous Layer Open Tubular) nas armadilhas do equipamento e o uso de diferentes temperaturas criogênicas permitiram verificar a coleta quantitativa dos gases, a separação do metano dos C2mais e a diminuição de algumas interferências que podem ser coletadas em nitrogênio líquido (N2 e O2). Igualmente, as interferências da água, CO2, N2 e O2 e olefinas foram minimizadas pela introdução de uma armadilha de limpeza do gás de arraste. A metodologia desenvolvida foi testada mediante a análise do headspace de sete sedimentos que apresentaram baixas concentrações de C2-C4 na determinação por CG-DIC-DCT (Cromatografia Gasosa com Detector de Ionização de Chama e Detector de Condutividade Térmica). Igualmente foi analisada uma amostra de gás confinado em um amostrador especial tipo Isotube. A determinação da composição isotópica destas amostras confirmou a aplicabilidade da metodologia e do sistema. Nas amostras de menor concentração, o metano foi oxidado no PreCon e os C2-C4 foram coletados no dispositivo de pré-concentração para posterior oxidação no sistema de CG-EMRI. Devido ao uso de dois fornos de combustão, a análise de metano apresentou maior variabilidade ( mais ou menos 2 por cento) e as tentativas de focalizar e oxidar o metano no forno do sistema de CG-EMRI foram pouco satisfatórias devido à co-eluição. Mediante a coluna PLOT inserida no dispositivo de pré-concentração foi possível coletar o metano, no entanto, a focalização foi pouco eficiente e o sinal do CO2 (do metano oxidado) apresentou interferentes não identificados. Assim, para facilitar e garantir a análise simultânea dos C1-C5, ainda é necessária a instalação de uma válvula que isole o reator do PreCon e permita a passagem direta dos C2mais até o sistema de focalização.
publishDate 2011
dc.date.issued.fl_str_mv 2011-10-06
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=19631@1
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=19631@2
url https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=19631@1
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=19631@2
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO
dc.publisher.program.fl_str_mv PPG EM QUÍMICA
dc.publisher.initials.fl_str_mv PUC-Rio
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO
dc.source.none.fl_str_mv reponame:Repositório Institucional da PUC-RIO (Projeto Maxwell)
instname:Pontifícia Universidade Católica do Rio de Janeiro (PUC-RIO)
instacron:PUC_RIO
instname_str Pontifícia Universidade Católica do Rio de Janeiro (PUC-RIO)
instacron_str PUC_RIO
institution PUC_RIO
reponame_str Repositório Institucional da PUC-RIO (Projeto Maxwell)
collection Repositório Institucional da PUC-RIO (Projeto Maxwell)
repository.name.fl_str_mv Repositório Institucional da PUC-RIO (Projeto Maxwell) - Pontifícia Universidade Católica do Rio de Janeiro (PUC-RIO)
repository.mail.fl_str_mv
_version_ 1748324912428220416