[pt] DESENVOLVIMENTO E APLICAÇÃO DE MÉTODOS ANALÍTICOS PARA DETERMINAÇÃO DE PICOXISTROBINA E PIRACLOSTROBINA POR CROMATOGRAFIA ELETROCINÉTICA CAPILAR MICELAR E DE ENROFLOXACINA POR FOSFORIMETRIA EM TEMPERATURA AMBIENTE

Detalhes bibliográficos
Autor(a) principal: CABRINI FERRAZ DE SOUZA
Data de Publicação: 2009
Tipo de documento: Outros
Idioma: por
Título da fonte: Repositório Institucional da PUC-RIO (Projeto Maxwell)
Texto Completo: https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=13068@1
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=13068@2
http://doi.org/10.17771/PUCRio.acad.13068
Resumo: [pt] No presente trabalho, a cromatografia eletrocinética capilar micelar (MECC) e a fosforimetria em temperatura ambiente em substrato sólido (SSRTP) foram utilizadas como técnicas analíticas para a determinação de duas estrobilurinas (picoxistrobina e piraclostrobina) e de uma fluoroquinolona (enrofloxacina), respectivamente. As condições ótimas de analise por MECC foram determinadas a partir de um estudo univariado dos seguintes parâmetros experimentais e instrumentais: pH do eletrólito de corrida, concentração do tampão, concentração de surfactante (dodecil-sulfato de sódio - SDS), tipo e quantidade de modificador orgânico, temperatura de trabalho e diferença de potencial aplicada. Depois de definidas as condições ótimas (tampão borato 40 mmol L-1, pH igual a 8,5; SDS 30 mmol L-1; acetonitrila 15 por cento em volume, 25 gruas Celsius e 25 kV) foi realizado um estudo para diminuir o limite de detecção (LD) e o limite de quantificação (LQ) do método. Para tal, foi usado o modo de pré-concentração no capilar denominado modo de empilhamento normal (NSM). Nessa abordagem, as soluções de padrões e amostras foram dissolvidas em uma solução de maior impedância (água: borato 40 mmol L-1 pH igual a 8,5 50:50 por cento v/v). Uma cela de caminho óptico alongado também foi utilizada para a tentativa de aumentar a sensibilidade do método. As curvas analíticas foram construídas com o uso de padrão interno (azoxistrobina) e apresentaram comportamento linear e homocedástico com valores de R2 próximos a 0,999. Com o modo NSM, os valores de LD (xb mais 3sb) e de LQ (xb mais 10sb) para a picoxistrobina e para a piraclostrobina ficaram na ordem de 10-7 mol L-1. A precisão do método (repetitividade e reprodutibilidade interna) apresentaram valores entre 5 e 8 por cento para tempo de migração e área dos picos. O método foi aplicado na análise de urina e água de riacho, ambas fortificadas com as estrobilurinas. As amostras de urina foram previamente passadas em coluna de extração em fase sólida (C-18). As recuperações obtidas para a piraclostrobina foram 75 mais ou menos 4 por cento para as amostras de urina e 94 ou menos 10 por cento para as amostras de água de riacho. Para a picoxistrobina os valores de recuperação foram de 109 mais ou menos 9 por cento e 102 mais ou menos 9 por cento para as amostras de urina e água do riacho respectivamente. As características fosforescentes da enrofloxacina foram estudadas de modo univariado em função de vários parâmetros experimentais tais como o tipo e quantidade de sal de átomo pesado indutor de fosforescência, presença de surfactante modificador de superfície de celulose, influência de concentração hidrogeniônica na solução do analito e estudo do tempo de exposição ao UV para a formação de fotoproduto de sinal mais estável. As melhores condições para o método fosforescente para enrofloxacina foram obtidas em solução básica (solução acetona: NaOH 0,05 mol L-1 50:50 por cento v/v) irradiada com UV por 30 min e substrato contendo 80 Vg de TlNO3. O método foi aplicado em formulações farmacêuticas contendo enrofloxacina e que são utilizadas na medicina veterinária (solução e comprimidos). Um método com a técnica de cromatografia líquida de alta eficiência (HPLC) adaptado da literatura foi utilizado para análise das amostras de enrofloxacina, sendo os resultados comparáveis àqueles obtidos por SSRTP. A curva analítica apresentou resposta linear e homoscedástica na faixa de trabalho escolhida com R2 maior que 0,99. Os valores de LD (xb mais 3sb) e de LQ (xb mais 10sb) foram respectivamente 2,1 and 4,8 ng respectivamente. A precisão (repetitividade e reprodutibilidade interna com troca de analista) do método apresentaram valores entre 2 e 19 por cento. A incerteza de medição do sinal fosforescente foi calculada usando o método sistemático indicado no ISO GUM e valores entre 18 e 26 por cento foram alcançados, com valores de repetitividade com troca de substrato a fonte mais importante de incerteza. No procedimento de validação, os valores de concentração de enrofloxacina encontrados nas amostras de medicamento analisadas por SSRTP e por HPLC foram estatisticamente semelhantes (valor de texperimental iguais a 0,48 e 1,04 sendo menor que o valor de tcrítico igual a 2,23).
id PUC_RIO-1_136aee369c91a9863ee171dcfa783161
oai_identifier_str oai:MAXWELL.puc-rio.br:13068
network_acronym_str PUC_RIO-1
network_name_str Repositório Institucional da PUC-RIO (Projeto Maxwell)
repository_id_str 534
spelling [pt] DESENVOLVIMENTO E APLICAÇÃO DE MÉTODOS ANALÍTICOS PARA DETERMINAÇÃO DE PICOXISTROBINA E PIRACLOSTROBINA POR CROMATOGRAFIA ELETROCINÉTICA CAPILAR MICELAR E DE ENROFLOXACINA POR FOSFORIMETRIA EM TEMPERATURA AMBIENTE[en] DEVELOPMENT AND APPLICATION OF ANALYTICAL METHODOS FOR THE DETERMINATION PICOXYSTROBIN AND PYRACLOSTROBIN BY MICELLAR ELECTROKINECTIC CAPILLARY CHROMATOGRAPHY AND ENROFLOXACIN BY ROOM-TEMPERATURE PHOSPHORIMETRY[pt] FOSFORIMETRIA NA TEMPERATURA AMBIENTE[pt] PIRACLOSTROBINA[pt] SUBSTRATO DE CELULOSE[en] ROOM-TEMPERATURE PHOSPHORIMETRY[en] PYRACLOSTROBIN[en] CELLULOSE SUBSTRATE[pt] No presente trabalho, a cromatografia eletrocinética capilar micelar (MECC) e a fosforimetria em temperatura ambiente em substrato sólido (SSRTP) foram utilizadas como técnicas analíticas para a determinação de duas estrobilurinas (picoxistrobina e piraclostrobina) e de uma fluoroquinolona (enrofloxacina), respectivamente. As condições ótimas de analise por MECC foram determinadas a partir de um estudo univariado dos seguintes parâmetros experimentais e instrumentais: pH do eletrólito de corrida, concentração do tampão, concentração de surfactante (dodecil-sulfato de sódio - SDS), tipo e quantidade de modificador orgânico, temperatura de trabalho e diferença de potencial aplicada. Depois de definidas as condições ótimas (tampão borato 40 mmol L-1, pH igual a 8,5; SDS 30 mmol L-1; acetonitrila 15 por cento em volume, 25 gruas Celsius e 25 kV) foi realizado um estudo para diminuir o limite de detecção (LD) e o limite de quantificação (LQ) do método. Para tal, foi usado o modo de pré-concentração no capilar denominado modo de empilhamento normal (NSM). Nessa abordagem, as soluções de padrões e amostras foram dissolvidas em uma solução de maior impedância (água: borato 40 mmol L-1 pH igual a 8,5 50:50 por cento v/v). Uma cela de caminho óptico alongado também foi utilizada para a tentativa de aumentar a sensibilidade do método. As curvas analíticas foram construídas com o uso de padrão interno (azoxistrobina) e apresentaram comportamento linear e homocedástico com valores de R2 próximos a 0,999. Com o modo NSM, os valores de LD (xb mais 3sb) e de LQ (xb mais 10sb) para a picoxistrobina e para a piraclostrobina ficaram na ordem de 10-7 mol L-1. A precisão do método (repetitividade e reprodutibilidade interna) apresentaram valores entre 5 e 8 por cento para tempo de migração e área dos picos. O método foi aplicado na análise de urina e água de riacho, ambas fortificadas com as estrobilurinas. As amostras de urina foram previamente passadas em coluna de extração em fase sólida (C-18). As recuperações obtidas para a piraclostrobina foram 75 mais ou menos 4 por cento para as amostras de urina e 94 ou menos 10 por cento para as amostras de água de riacho. Para a picoxistrobina os valores de recuperação foram de 109 mais ou menos 9 por cento e 102 mais ou menos 9 por cento para as amostras de urina e água do riacho respectivamente. As características fosforescentes da enrofloxacina foram estudadas de modo univariado em função de vários parâmetros experimentais tais como o tipo e quantidade de sal de átomo pesado indutor de fosforescência, presença de surfactante modificador de superfície de celulose, influência de concentração hidrogeniônica na solução do analito e estudo do tempo de exposição ao UV para a formação de fotoproduto de sinal mais estável. As melhores condições para o método fosforescente para enrofloxacina foram obtidas em solução básica (solução acetona: NaOH 0,05 mol L-1 50:50 por cento v/v) irradiada com UV por 30 min e substrato contendo 80 Vg de TlNO3. O método foi aplicado em formulações farmacêuticas contendo enrofloxacina e que são utilizadas na medicina veterinária (solução e comprimidos). Um método com a técnica de cromatografia líquida de alta eficiência (HPLC) adaptado da literatura foi utilizado para análise das amostras de enrofloxacina, sendo os resultados comparáveis àqueles obtidos por SSRTP. A curva analítica apresentou resposta linear e homoscedástica na faixa de trabalho escolhida com R2 maior que 0,99. Os valores de LD (xb mais 3sb) e de LQ (xb mais 10sb) foram respectivamente 2,1 and 4,8 ng respectivamente. A precisão (repetitividade e reprodutibilidade interna com troca de analista) do método apresentaram valores entre 2 e 19 por cento. A incerteza de medição do sinal fosforescente foi calculada usando o método sistemático indicado no ISO GUM e valores entre 18 e 26 por cento foram alcançados, com valores de repetitividade com troca de substrato a fonte mais importante de incerteza. No procedimento de validação, os valores de concentração de enrofloxacina encontrados nas amostras de medicamento analisadas por SSRTP e por HPLC foram estatisticamente semelhantes (valor de texperimental iguais a 0,48 e 1,04 sendo menor que o valor de tcrítico igual a 2,23).[en] In the present work, micellar electrokinectic capillary chromatography (MECC) and solid surface room-temperature phosphorimetry (SSRTP) were used as analytical techniques for the determination of two strobilurins (picoxystrobin and pyraclostrobin) and of one fluoroquinolones (enrofloxacin), respectively. The experimental conditions for MECC have been optimized using an univariate approach for the following experimental and instrumental parameters: pH of the working electrolyte, concentration of the buffer, concentration of surfactant (sodium dodecyl-sulphate - SDS), type and amount of organic modifier, working temperature and applied potential. After defined the best conditions (borate buffer 40 mmol L(-1) pH=8.5; 30 SDS mmol L(-1); acetonitrile 15% in volume, 25 ºC and 25 kV), a study was carried through to improve the limit of detention (LD) and the limit of quantification (LQ) of the method. In order to do that, an on-line analyte pre-concentration called normal stacking mode (NSM) was used. In such approach, the standards and samples have been dissolved in a solution of higher impedance (water: borate 40 mmol L(-1) pH=8.5 50:50% v/v). A high sensitivity detection cell also was used to attempt the increasing of the sensitivity of the method. The analytical curves have been constructed with the use of an internal standard (azoxystrobin) and a linear response and homocedastic behavior were observed with R2 values of at least 0.999. The NSM mode allowed the values of LD (x(b) + 3(sb)) and of LQ (x(b) + 10(sb)) in the order of 10(-7) mol L(-1) for picoxystrobina and pyraclostrobina. The precision of the method (repeatability and intermediate precision) was characterized by values between 5 and 8%. The method was applied in the analysis urine and stream water, both type of samples fortified with the strobilurins. The urine sample was previously passed through a solid phase extraction column (C-18). The recoveries achieved for pyraclostrobina were 75  +- 4% for urine and 94  +- 10% for stream water samples. For picoxystrobin, the recovery values were 109  +- 9% and 102  +- 9% respectively for urine and stream water samples. The phosphorimetric characteristics of enrofloxacin have been studied in an unvaried way for experimental parameters such as the type and quantity of phosphorescence inducer (heavy atom salt), surfactant used as cellulose surface modifier, influence of the hidrogenionic concentration in the analyte solution and study of the UV exposition time for the formation of a more signal stable photoproduct. The best conditions for the phosphorimetric method for enrofloxacin were the use of basic solution (solution acetone: NaOH 0.05 mol L-1 50:50% v/v) irradiated with UV for 30 min and cellulose substrates containing 80 Vg of TlNO3. The method was applied in pharmaceutical formulations containing enrofloxacin employed in veterinary medicine (solution and pills). A method based on high efficiency liquid chromatography (HPLC), adapted from literature, was used as a reference method and the the results obtained for enrofloxacin was comparable to the ones achieved by SSRTP. The analytical curve presented linear and homocedastic behavior with R2 values higher than 0.99. The LD (x(b) + 3(sb)) and the LQ (x(b) + 10(sb)) values were 2.1 and 4.8 ng respectively. The precision (repeatability and intermediate precision with change of analyst) of the method presented values between 2 and 19%. The uncertainty of the phosphorescence measurement was calculated using the systematic method indicated in the ISO GUM. Values between 18 and 26% had been achieved, with the repeatability with substrate change the most important source uncertainty. In the validation procedure, enrofloxacin concentration values found in the medicine samples analyzed by SSRTP and HPLC were statistically similar ( t(experimental) value of 0.48 and 1.04 smaller than the t(critic) value of 2.23).MAXWELLRICARDO QUEIROZ AUCELIOCABRINI FERRAZ DE SOUZA2009-03-02info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/otherhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=13068@1https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=13068@2http://doi.org/10.17771/PUCRio.acad.13068porreponame:Repositório Institucional da PUC-RIO (Projeto Maxwell)instname:Pontifícia Universidade Católica do Rio de Janeiro (PUC-RIO)instacron:PUC_RIOinfo:eu-repo/semantics/openAccess2024-01-04T00:00:00Zoai:MAXWELL.puc-rio.br:13068Repositório InstitucionalPRIhttps://www.maxwell.vrac.puc-rio.br/ibict.phpopendoar:5342024-01-04T00:00Repositório Institucional da PUC-RIO (Projeto Maxwell) - Pontifícia Universidade Católica do Rio de Janeiro (PUC-RIO)false
dc.title.none.fl_str_mv [pt] DESENVOLVIMENTO E APLICAÇÃO DE MÉTODOS ANALÍTICOS PARA DETERMINAÇÃO DE PICOXISTROBINA E PIRACLOSTROBINA POR CROMATOGRAFIA ELETROCINÉTICA CAPILAR MICELAR E DE ENROFLOXACINA POR FOSFORIMETRIA EM TEMPERATURA AMBIENTE
[en] DEVELOPMENT AND APPLICATION OF ANALYTICAL METHODOS FOR THE DETERMINATION PICOXYSTROBIN AND PYRACLOSTROBIN BY MICELLAR ELECTROKINECTIC CAPILLARY CHROMATOGRAPHY AND ENROFLOXACIN BY ROOM-TEMPERATURE PHOSPHORIMETRY
title [pt] DESENVOLVIMENTO E APLICAÇÃO DE MÉTODOS ANALÍTICOS PARA DETERMINAÇÃO DE PICOXISTROBINA E PIRACLOSTROBINA POR CROMATOGRAFIA ELETROCINÉTICA CAPILAR MICELAR E DE ENROFLOXACINA POR FOSFORIMETRIA EM TEMPERATURA AMBIENTE
spellingShingle [pt] DESENVOLVIMENTO E APLICAÇÃO DE MÉTODOS ANALÍTICOS PARA DETERMINAÇÃO DE PICOXISTROBINA E PIRACLOSTROBINA POR CROMATOGRAFIA ELETROCINÉTICA CAPILAR MICELAR E DE ENROFLOXACINA POR FOSFORIMETRIA EM TEMPERATURA AMBIENTE
CABRINI FERRAZ DE SOUZA
[pt] FOSFORIMETRIA NA TEMPERATURA AMBIENTE
[pt] PIRACLOSTROBINA
[pt] SUBSTRATO DE CELULOSE
[en] ROOM-TEMPERATURE PHOSPHORIMETRY
[en] PYRACLOSTROBIN
[en] CELLULOSE SUBSTRATE
title_short [pt] DESENVOLVIMENTO E APLICAÇÃO DE MÉTODOS ANALÍTICOS PARA DETERMINAÇÃO DE PICOXISTROBINA E PIRACLOSTROBINA POR CROMATOGRAFIA ELETROCINÉTICA CAPILAR MICELAR E DE ENROFLOXACINA POR FOSFORIMETRIA EM TEMPERATURA AMBIENTE
title_full [pt] DESENVOLVIMENTO E APLICAÇÃO DE MÉTODOS ANALÍTICOS PARA DETERMINAÇÃO DE PICOXISTROBINA E PIRACLOSTROBINA POR CROMATOGRAFIA ELETROCINÉTICA CAPILAR MICELAR E DE ENROFLOXACINA POR FOSFORIMETRIA EM TEMPERATURA AMBIENTE
title_fullStr [pt] DESENVOLVIMENTO E APLICAÇÃO DE MÉTODOS ANALÍTICOS PARA DETERMINAÇÃO DE PICOXISTROBINA E PIRACLOSTROBINA POR CROMATOGRAFIA ELETROCINÉTICA CAPILAR MICELAR E DE ENROFLOXACINA POR FOSFORIMETRIA EM TEMPERATURA AMBIENTE
title_full_unstemmed [pt] DESENVOLVIMENTO E APLICAÇÃO DE MÉTODOS ANALÍTICOS PARA DETERMINAÇÃO DE PICOXISTROBINA E PIRACLOSTROBINA POR CROMATOGRAFIA ELETROCINÉTICA CAPILAR MICELAR E DE ENROFLOXACINA POR FOSFORIMETRIA EM TEMPERATURA AMBIENTE
title_sort [pt] DESENVOLVIMENTO E APLICAÇÃO DE MÉTODOS ANALÍTICOS PARA DETERMINAÇÃO DE PICOXISTROBINA E PIRACLOSTROBINA POR CROMATOGRAFIA ELETROCINÉTICA CAPILAR MICELAR E DE ENROFLOXACINA POR FOSFORIMETRIA EM TEMPERATURA AMBIENTE
author CABRINI FERRAZ DE SOUZA
author_facet CABRINI FERRAZ DE SOUZA
author_role author
dc.contributor.none.fl_str_mv RICARDO QUEIROZ AUCELIO
dc.contributor.author.fl_str_mv CABRINI FERRAZ DE SOUZA
dc.subject.por.fl_str_mv [pt] FOSFORIMETRIA NA TEMPERATURA AMBIENTE
[pt] PIRACLOSTROBINA
[pt] SUBSTRATO DE CELULOSE
[en] ROOM-TEMPERATURE PHOSPHORIMETRY
[en] PYRACLOSTROBIN
[en] CELLULOSE SUBSTRATE
topic [pt] FOSFORIMETRIA NA TEMPERATURA AMBIENTE
[pt] PIRACLOSTROBINA
[pt] SUBSTRATO DE CELULOSE
[en] ROOM-TEMPERATURE PHOSPHORIMETRY
[en] PYRACLOSTROBIN
[en] CELLULOSE SUBSTRATE
description [pt] No presente trabalho, a cromatografia eletrocinética capilar micelar (MECC) e a fosforimetria em temperatura ambiente em substrato sólido (SSRTP) foram utilizadas como técnicas analíticas para a determinação de duas estrobilurinas (picoxistrobina e piraclostrobina) e de uma fluoroquinolona (enrofloxacina), respectivamente. As condições ótimas de analise por MECC foram determinadas a partir de um estudo univariado dos seguintes parâmetros experimentais e instrumentais: pH do eletrólito de corrida, concentração do tampão, concentração de surfactante (dodecil-sulfato de sódio - SDS), tipo e quantidade de modificador orgânico, temperatura de trabalho e diferença de potencial aplicada. Depois de definidas as condições ótimas (tampão borato 40 mmol L-1, pH igual a 8,5; SDS 30 mmol L-1; acetonitrila 15 por cento em volume, 25 gruas Celsius e 25 kV) foi realizado um estudo para diminuir o limite de detecção (LD) e o limite de quantificação (LQ) do método. Para tal, foi usado o modo de pré-concentração no capilar denominado modo de empilhamento normal (NSM). Nessa abordagem, as soluções de padrões e amostras foram dissolvidas em uma solução de maior impedância (água: borato 40 mmol L-1 pH igual a 8,5 50:50 por cento v/v). Uma cela de caminho óptico alongado também foi utilizada para a tentativa de aumentar a sensibilidade do método. As curvas analíticas foram construídas com o uso de padrão interno (azoxistrobina) e apresentaram comportamento linear e homocedástico com valores de R2 próximos a 0,999. Com o modo NSM, os valores de LD (xb mais 3sb) e de LQ (xb mais 10sb) para a picoxistrobina e para a piraclostrobina ficaram na ordem de 10-7 mol L-1. A precisão do método (repetitividade e reprodutibilidade interna) apresentaram valores entre 5 e 8 por cento para tempo de migração e área dos picos. O método foi aplicado na análise de urina e água de riacho, ambas fortificadas com as estrobilurinas. As amostras de urina foram previamente passadas em coluna de extração em fase sólida (C-18). As recuperações obtidas para a piraclostrobina foram 75 mais ou menos 4 por cento para as amostras de urina e 94 ou menos 10 por cento para as amostras de água de riacho. Para a picoxistrobina os valores de recuperação foram de 109 mais ou menos 9 por cento e 102 mais ou menos 9 por cento para as amostras de urina e água do riacho respectivamente. As características fosforescentes da enrofloxacina foram estudadas de modo univariado em função de vários parâmetros experimentais tais como o tipo e quantidade de sal de átomo pesado indutor de fosforescência, presença de surfactante modificador de superfície de celulose, influência de concentração hidrogeniônica na solução do analito e estudo do tempo de exposição ao UV para a formação de fotoproduto de sinal mais estável. As melhores condições para o método fosforescente para enrofloxacina foram obtidas em solução básica (solução acetona: NaOH 0,05 mol L-1 50:50 por cento v/v) irradiada com UV por 30 min e substrato contendo 80 Vg de TlNO3. O método foi aplicado em formulações farmacêuticas contendo enrofloxacina e que são utilizadas na medicina veterinária (solução e comprimidos). Um método com a técnica de cromatografia líquida de alta eficiência (HPLC) adaptado da literatura foi utilizado para análise das amostras de enrofloxacina, sendo os resultados comparáveis àqueles obtidos por SSRTP. A curva analítica apresentou resposta linear e homoscedástica na faixa de trabalho escolhida com R2 maior que 0,99. Os valores de LD (xb mais 3sb) e de LQ (xb mais 10sb) foram respectivamente 2,1 and 4,8 ng respectivamente. A precisão (repetitividade e reprodutibilidade interna com troca de analista) do método apresentaram valores entre 2 e 19 por cento. A incerteza de medição do sinal fosforescente foi calculada usando o método sistemático indicado no ISO GUM e valores entre 18 e 26 por cento foram alcançados, com valores de repetitividade com troca de substrato a fonte mais importante de incerteza. No procedimento de validação, os valores de concentração de enrofloxacina encontrados nas amostras de medicamento analisadas por SSRTP e por HPLC foram estatisticamente semelhantes (valor de texperimental iguais a 0,48 e 1,04 sendo menor que o valor de tcrítico igual a 2,23).
publishDate 2009
dc.date.none.fl_str_mv 2009-03-02
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/other
format other
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=13068@1
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=13068@2
http://doi.org/10.17771/PUCRio.acad.13068
url https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=13068@1
https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=13068@2
http://doi.org/10.17771/PUCRio.acad.13068
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv MAXWELL
publisher.none.fl_str_mv MAXWELL
dc.source.none.fl_str_mv reponame:Repositório Institucional da PUC-RIO (Projeto Maxwell)
instname:Pontifícia Universidade Católica do Rio de Janeiro (PUC-RIO)
instacron:PUC_RIO
instname_str Pontifícia Universidade Católica do Rio de Janeiro (PUC-RIO)
instacron_str PUC_RIO
institution PUC_RIO
reponame_str Repositório Institucional da PUC-RIO (Projeto Maxwell)
collection Repositório Institucional da PUC-RIO (Projeto Maxwell)
repository.name.fl_str_mv Repositório Institucional da PUC-RIO (Projeto Maxwell) - Pontifícia Universidade Católica do Rio de Janeiro (PUC-RIO)
repository.mail.fl_str_mv
_version_ 1814822571068096512