Radiopacity of the modified Portland cement in comparison with MTA
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista odonto ciência (Online) |
Texto Completo: | https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2540 |
Resumo: | Purpose: This in vitro study used digital images to measure the radiopacity of the Portland cement (PC) containing or not radiopaque substances in relation to the radiopacity of the Mineral Trioxide Aggregate (MTA) cement. Methods: Three specimens were fabricated for each of the following five groups: 1) ProRoot MTA (Dentsply); 2) Portland cement – PC (Goiás); 3) PC + 2% uranyl acetate solution; 4) PC + 2% PTA solution; 5) PC + lead citrate solution. Specimens were stored in room temperature for 28 days and their radiopacity was measured by means of a direct digital radiography system (Sens-A-Ray), using the analytical functions line profile graph and histogram. Results: ProRoot MTA group showed the highest radiopacity; Portland cement radiopacity was approximately 60% of the MTA value. The tested solutions increased the radiopacity of Portland cement in the following rates: PTA=7%, uranyl acetate =12.5% and lead citrate =11%. Conclusion: The addition of radiopaque substances increased radiopacity of the original Portland cement, but it did not reach the level of ProRoot MTA radiopacity. Key words: Dental cements; MTA; Portland cement; radiopacity |
id |
PUC_RS-22_1c2ab0790c95e1f531b7799220c5f988 |
---|---|
oai_identifier_str |
oai:ojs.revistaseletronicas.pucrs.br:article/2540 |
network_acronym_str |
PUC_RS-22 |
network_name_str |
Revista odonto ciência (Online) |
repository_id_str |
|
spelling |
Radiopacity of the modified Portland cement in comparison with MTARadiopacidade do cimento Portland modificado em comparação com o MTADental cementsMTAPortland cementradiopacityEndodonticsPurpose: This in vitro study used digital images to measure the radiopacity of the Portland cement (PC) containing or not radiopaque substances in relation to the radiopacity of the Mineral Trioxide Aggregate (MTA) cement. Methods: Three specimens were fabricated for each of the following five groups: 1) ProRoot MTA (Dentsply); 2) Portland cement – PC (Goiás); 3) PC + 2% uranyl acetate solution; 4) PC + 2% PTA solution; 5) PC + lead citrate solution. Specimens were stored in room temperature for 28 days and their radiopacity was measured by means of a direct digital radiography system (Sens-A-Ray), using the analytical functions line profile graph and histogram. Results: ProRoot MTA group showed the highest radiopacity; Portland cement radiopacity was approximately 60% of the MTA value. The tested solutions increased the radiopacity of Portland cement in the following rates: PTA=7%, uranyl acetate =12.5% and lead citrate =11%. Conclusion: The addition of radiopaque substances increased radiopacity of the original Portland cement, but it did not reach the level of ProRoot MTA radiopacity. Key words: Dental cements; MTA; Portland cement; radiopacityObjetivo: Este estudo in vitro utilizou imagem digital para medir a radiopacidade do cimento Portland (CP), isoladamente ou associado a substâncias radiopatizantes, com referência à radiopacidade do Agregado do Trióxido Mineral (MTA). Metodologia: Três espécimes foram preparados para cada um dos seguintes grupos: 1) ProRoot MTA (Dentsply); 2) cimento Portland – CP (Goiás); 3) CP + solução de acetato de uranila a 2%; 4) CP + de solução de PTA a 2%; 5) CP + solução de citrato de chumbo. Os espécimes foram armazenados por 28 dias em temperatura ambiente e a radiopacidade foi medida com um sistema de radiografia digital direta (Sens-A-Ray), usando as funções gráfico de perfil de linha e histograma. Resultados: O grupo ProRoot MTA apresentou a maior radiopacidade; a radiopacidade do cimento Portland foi aproximadamente 60% a do MTA. As soluções testadas aumentaram a radiopacidade do cimento Portland nas seguintes taxas: PTA=7%, acetato de uranila=12,5% e citrato de chumbo=11%. Conclusão: A adição de soluções radiopatizantes aumentou a radiopacidade padrão do cimento Portland, mas sem atingir o grau de radiopacidade do cimento ProRoot MTA. Palavras-chave: Cimentos dentários; MTA; cimento Portland; radiopacidadeEDIPUCRS - Editora Universitária da PUCRS2008-06-22info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articlein vitro; descriptiveapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2540Revista Odonto Ciência; Vol. 23 No. 2 (2008); 145 - 149Revista Odonto Ciência; v. 23 n. 2 (2008); 145 - 1491980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2540/3046Leites, Antônio Césarde Figueiredo, José Antônio PoliDemarco, Flávio FernandoBasso, Ana PaulaPiva, Evandroinfo:eu-repo/semantics/openAccess2013-11-18T10:48:09Zoai:ojs.revistaseletronicas.pucrs.br:article/2540Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-18T10:48:09Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false |
dc.title.none.fl_str_mv |
Radiopacity of the modified Portland cement in comparison with MTA Radiopacidade do cimento Portland modificado em comparação com o MTA |
title |
Radiopacity of the modified Portland cement in comparison with MTA |
spellingShingle |
Radiopacity of the modified Portland cement in comparison with MTA Leites, Antônio César Dental cements MTA Portland cement radiopacity Endodontics |
title_short |
Radiopacity of the modified Portland cement in comparison with MTA |
title_full |
Radiopacity of the modified Portland cement in comparison with MTA |
title_fullStr |
Radiopacity of the modified Portland cement in comparison with MTA |
title_full_unstemmed |
Radiopacity of the modified Portland cement in comparison with MTA |
title_sort |
Radiopacity of the modified Portland cement in comparison with MTA |
author |
Leites, Antônio César |
author_facet |
Leites, Antônio César de Figueiredo, José Antônio Poli Demarco, Flávio Fernando Basso, Ana Paula Piva, Evandro |
author_role |
author |
author2 |
de Figueiredo, José Antônio Poli Demarco, Flávio Fernando Basso, Ana Paula Piva, Evandro |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Leites, Antônio César de Figueiredo, José Antônio Poli Demarco, Flávio Fernando Basso, Ana Paula Piva, Evandro |
dc.subject.por.fl_str_mv |
Dental cements MTA Portland cement radiopacity Endodontics |
topic |
Dental cements MTA Portland cement radiopacity Endodontics |
description |
Purpose: This in vitro study used digital images to measure the radiopacity of the Portland cement (PC) containing or not radiopaque substances in relation to the radiopacity of the Mineral Trioxide Aggregate (MTA) cement. Methods: Three specimens were fabricated for each of the following five groups: 1) ProRoot MTA (Dentsply); 2) Portland cement – PC (Goiás); 3) PC + 2% uranyl acetate solution; 4) PC + 2% PTA solution; 5) PC + lead citrate solution. Specimens were stored in room temperature for 28 days and their radiopacity was measured by means of a direct digital radiography system (Sens-A-Ray), using the analytical functions line profile graph and histogram. Results: ProRoot MTA group showed the highest radiopacity; Portland cement radiopacity was approximately 60% of the MTA value. The tested solutions increased the radiopacity of Portland cement in the following rates: PTA=7%, uranyl acetate =12.5% and lead citrate =11%. Conclusion: The addition of radiopaque substances increased radiopacity of the original Portland cement, but it did not reach the level of ProRoot MTA radiopacity. Key words: Dental cements; MTA; Portland cement; radiopacity |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-06-22 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Peer-reviewed Article in vitro; descriptive |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2540 |
url |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2540 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2540/3046 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
dc.source.none.fl_str_mv |
Revista Odonto Ciência; Vol. 23 No. 2 (2008); 145 - 149 Revista Odonto Ciência; v. 23 n. 2 (2008); 145 - 149 1980-6523 0102-9460 reponame:Revista odonto ciência (Online) instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) instacron:PUC_RS |
instname_str |
Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
instacron_str |
PUC_RS |
institution |
PUC_RS |
reponame_str |
Revista odonto ciência (Online) |
collection |
Revista odonto ciência (Online) |
repository.name.fl_str_mv |
Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
repository.mail.fl_str_mv |
||odontociencia@pucrs.br |
_version_ |
1754820874209329152 |