In vitro evaluation of shear bond strength and fluoride release from two resin-reinforced glass ionomer cements
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista odonto ciência (Online) |
Texto Completo: | https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1281 |
Resumo: | The objective of this study was to evaluate two resin-reinforced glass ionomer cements, Fuji Ortho LC and Fuji Ortho Band (GC América Corporation, Tokyo, Japan) in terms of shear bond strength and fluoride release. Sixty bovine permanent lower incisors were divided into three groups (n = 15). In Groups 1, 2, and 3 the bonding procedures were performed with Transbond XT, Fuji Ortho LC, and Fuji Ortho Band materials respectively. Next, the samples were submitted to bond strength testing at crosshead speed of 0.5 mm/minute. Fluoride release from such materials was measured during 28 days (1h, 24 h, 3, 7, 14, 21, and 28 days) by means of selective ion electrodes connected to an ion analyser. With respect to the shear bond strength (MPa), the results demonstrated statistical differences between groups 1 and 3 as well as between groups 2 and 3. With respect to the fluoride release, the results showed statistically significant results between groups 1 and 3 as well as between groups 2 and 3 for all time periods (p = 0.00). Also, the 3-day evaluation showed statistical differences between groups 1 and 2 regarding fluoride release (p = 0.00). Based on the results obtained in the present study, one can conclude that Transbond XT and Fuji Ortho materials have a better shear bond strength than the Fuji Ortho Band one, although the latter releases less fluoride. UNITERMS: glass ionomer cements; composite; shear strength; fluoride release. |
id |
PUC_RS-22_3c04feadd00b21a870566cdac66e881d |
---|---|
oai_identifier_str |
oai:ojs.revistaseletronicas.pucrs.br:article/1281 |
network_acronym_str |
PUC_RS-22 |
network_name_str |
Revista odonto ciência (Online) |
repository_id_str |
|
spelling |
In vitro evaluation of shear bond strength and fluoride release from two resin-reinforced glass ionomer cementsAvaliação in vitro da resistência ao cisalhamento e liberação de flúor de dois cimentos de ionômero de vidro reforçado por resinaglass ionomer cementscompositeshear strengthfluoride releaseFluoride releaseThe objective of this study was to evaluate two resin-reinforced glass ionomer cements, Fuji Ortho LC and Fuji Ortho Band (GC América Corporation, Tokyo, Japan) in terms of shear bond strength and fluoride release. Sixty bovine permanent lower incisors were divided into three groups (n = 15). In Groups 1, 2, and 3 the bonding procedures were performed with Transbond XT, Fuji Ortho LC, and Fuji Ortho Band materials respectively. Next, the samples were submitted to bond strength testing at crosshead speed of 0.5 mm/minute. Fluoride release from such materials was measured during 28 days (1h, 24 h, 3, 7, 14, 21, and 28 days) by means of selective ion electrodes connected to an ion analyser. With respect to the shear bond strength (MPa), the results demonstrated statistical differences between groups 1 and 3 as well as between groups 2 and 3. With respect to the fluoride release, the results showed statistically significant results between groups 1 and 3 as well as between groups 2 and 3 for all time periods (p = 0.00). Also, the 3-day evaluation showed statistical differences between groups 1 and 2 regarding fluoride release (p = 0.00). Based on the results obtained in the present study, one can conclude that Transbond XT and Fuji Ortho materials have a better shear bond strength than the Fuji Ortho Band one, although the latter releases less fluoride. UNITERMS: glass ionomer cements; composite; shear strength; fluoride release.O objetivo deste estudo foi avaliar os cimentos de ionômero de vidro reforçados com resina Fuji Ortho LC e Fuji Ortho Band (GC América Corporation, Tokyo, Japan) quanto a resistência ao cisalhamento e liberação de flúor. Para avaliação da resistência ao cisalhamento utilizou-se 60 incisivos inferiores permanentes bovinos divididos em três grupos (n = 15). No Grupo 1, 2 e 3, as colagens foram realizadas com Transbond XT, Fuji Ortho LC e Fuji Ortho Band respectivamente. Após a colagem realizou-se o ensaio de cisalhamento de toda amostra à velocidade de 0,5 mm por minuto. A liberação de flúor dos materiais foram medidas durante 28 dias (1h, 24 h, 3, 7, 14, 21 e 28 dias) através de eletrodo íon seletivo conectado a um analisador de íons. Os resultados demonstraram que quanto a resistência ao cisalhamento (MPa) houve diferenças estatísticas entre os grupos 1 e 3, 2 e 3 (p > 0,05). Quanto a liberação de flúor os resultados evidenciaram diferença estatisticamente significante entre os grupos 1 e 3 e 2 e 3 em todos os tempos (p = 0.00) e entre os grupos 1 e 2 na avaliação de 3 dias de liberação de flúor (p = 0.00). Baseado nos resultados obtidos conclui-se que os materiais Transbond XT e Fuji Ortho possuem melhor resistência ao cisalhamento porém menor liberação de flúor quando comparado ao Fuji Ortho Band. UNITERMOS: cimento de ionômero de vidro; compósito; resistência ao cisalhamento; liberação de flúor.EDIPUCRS - Editora Universitária da PUCRS2007-12-27info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articlelaboratory; in vitro; experimentalapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1281Revista Odonto Ciência; Vol. 22 No. 58 (2007); 305 - 310Revista Odonto Ciência; v. 22 n. 58 (2007); 305 - 3101980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1281/1911Pithon, Matheus Melode Oliveira, Márlio Viníciusdos Santos, Rogério LacerdaBolognese, Ana MariaRuellas, Antônio Carlos de Oliveirainfo:eu-repo/semantics/openAccess2013-11-18T11:02:30Zoai:ojs.revistaseletronicas.pucrs.br:article/1281Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-18T11:02:30Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false |
dc.title.none.fl_str_mv |
In vitro evaluation of shear bond strength and fluoride release from two resin-reinforced glass ionomer cements Avaliação in vitro da resistência ao cisalhamento e liberação de flúor de dois cimentos de ionômero de vidro reforçado por resina |
title |
In vitro evaluation of shear bond strength and fluoride release from two resin-reinforced glass ionomer cements |
spellingShingle |
In vitro evaluation of shear bond strength and fluoride release from two resin-reinforced glass ionomer cements Pithon, Matheus Melo glass ionomer cements composite shear strength fluoride release Fluoride release |
title_short |
In vitro evaluation of shear bond strength and fluoride release from two resin-reinforced glass ionomer cements |
title_full |
In vitro evaluation of shear bond strength and fluoride release from two resin-reinforced glass ionomer cements |
title_fullStr |
In vitro evaluation of shear bond strength and fluoride release from two resin-reinforced glass ionomer cements |
title_full_unstemmed |
In vitro evaluation of shear bond strength and fluoride release from two resin-reinforced glass ionomer cements |
title_sort |
In vitro evaluation of shear bond strength and fluoride release from two resin-reinforced glass ionomer cements |
author |
Pithon, Matheus Melo |
author_facet |
Pithon, Matheus Melo de Oliveira, Márlio Vinícius dos Santos, Rogério Lacerda Bolognese, Ana Maria Ruellas, Antônio Carlos de Oliveira |
author_role |
author |
author2 |
de Oliveira, Márlio Vinícius dos Santos, Rogério Lacerda Bolognese, Ana Maria Ruellas, Antônio Carlos de Oliveira |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Pithon, Matheus Melo de Oliveira, Márlio Vinícius dos Santos, Rogério Lacerda Bolognese, Ana Maria Ruellas, Antônio Carlos de Oliveira |
dc.subject.por.fl_str_mv |
glass ionomer cements composite shear strength fluoride release Fluoride release |
topic |
glass ionomer cements composite shear strength fluoride release Fluoride release |
description |
The objective of this study was to evaluate two resin-reinforced glass ionomer cements, Fuji Ortho LC and Fuji Ortho Band (GC América Corporation, Tokyo, Japan) in terms of shear bond strength and fluoride release. Sixty bovine permanent lower incisors were divided into three groups (n = 15). In Groups 1, 2, and 3 the bonding procedures were performed with Transbond XT, Fuji Ortho LC, and Fuji Ortho Band materials respectively. Next, the samples were submitted to bond strength testing at crosshead speed of 0.5 mm/minute. Fluoride release from such materials was measured during 28 days (1h, 24 h, 3, 7, 14, 21, and 28 days) by means of selective ion electrodes connected to an ion analyser. With respect to the shear bond strength (MPa), the results demonstrated statistical differences between groups 1 and 3 as well as between groups 2 and 3. With respect to the fluoride release, the results showed statistically significant results between groups 1 and 3 as well as between groups 2 and 3 for all time periods (p = 0.00). Also, the 3-day evaluation showed statistical differences between groups 1 and 2 regarding fluoride release (p = 0.00). Based on the results obtained in the present study, one can conclude that Transbond XT and Fuji Ortho materials have a better shear bond strength than the Fuji Ortho Band one, although the latter releases less fluoride. UNITERMS: glass ionomer cements; composite; shear strength; fluoride release. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-12-27 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Peer-reviewed Article laboratory; in vitro; experimental |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1281 |
url |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1281 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1281/1911 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
dc.source.none.fl_str_mv |
Revista Odonto Ciência; Vol. 22 No. 58 (2007); 305 - 310 Revista Odonto Ciência; v. 22 n. 58 (2007); 305 - 310 1980-6523 0102-9460 reponame:Revista odonto ciência (Online) instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) instacron:PUC_RS |
instname_str |
Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
instacron_str |
PUC_RS |
institution |
PUC_RS |
reponame_str |
Revista odonto ciência (Online) |
collection |
Revista odonto ciência (Online) |
repository.name.fl_str_mv |
Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
repository.mail.fl_str_mv |
||odontociencia@pucrs.br |
_version_ |
1754820873754247168 |