Radiopacity of impression materials using an indirect digital system
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista odonto ciência (Online) |
Texto Completo: | https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/3973 |
Resumo: | Purpose: This in vitro study evaluated the radiopacity of impression materials using an indirect digital system. Methods: Samples of four polyvinyl siloxanes, one polyether, one polysulfide, and one irreversible hydrocolloid were fabricated with 1.0, 1.5, and 3.5mm-thickness. Three samples of different thickness were placed on the Digora optical plate and exposed. The optical density (pixels) was recorded in three areas resulting in a total of 360 measurements. Data were analyzed by 2-way ANOVA and Tukey tests (α=0.05). Results: Significant differences were observed among all materials and thicknesses tested (P<0.001). Irreversible hydrocolloid and polyether showed the lowest optical density. Polysulfide showed the highest optical density under all evaluated conditions. Conclusion: There was a significant difference in optical density for all impression materials tested. Composition changes are suggested to allow radiographic detection and improve safety during clinical use of impression materials. Key words: Optical density; digital dental radiography; dental impression materials |
id |
PUC_RS-22_86bc6749f24a2c347bbf0e237c8a2485 |
---|---|
oai_identifier_str |
oai:ojs.revistaseletronicas.pucrs.br:article/3973 |
network_acronym_str |
PUC_RS-22 |
network_name_str |
Revista odonto ciência (Online) |
repository_id_str |
|
spelling |
Radiopacity of impression materials using an indirect digital systemRadiopacidade de materiais de moldagem usando um sistema digital indiretoOptical densitydigital dental radiographydental impression materialsradiopacitydental impression materialsPurpose: This in vitro study evaluated the radiopacity of impression materials using an indirect digital system. Methods: Samples of four polyvinyl siloxanes, one polyether, one polysulfide, and one irreversible hydrocolloid were fabricated with 1.0, 1.5, and 3.5mm-thickness. Three samples of different thickness were placed on the Digora optical plate and exposed. The optical density (pixels) was recorded in three areas resulting in a total of 360 measurements. Data were analyzed by 2-way ANOVA and Tukey tests (α=0.05). Results: Significant differences were observed among all materials and thicknesses tested (P<0.001). Irreversible hydrocolloid and polyether showed the lowest optical density. Polysulfide showed the highest optical density under all evaluated conditions. Conclusion: There was a significant difference in optical density for all impression materials tested. Composition changes are suggested to allow radiographic detection and improve safety during clinical use of impression materials. Key words: Optical density; digital dental radiography; dental impression materialsObjetivo: Este estudo in vitro comparou a radiopacidade de materiais de moldagem usando um método radiográfico digital indireto. Metodologia: Amostras de quatro polivinil-siloxanos, um poliéter, um polissulfeto e um hidrocolóide irreversível foram confeccionadas com alturas de 1, 1,5 e 3,5mm. Três amostras das diferentes espessuras foram dispostas sobre uma placa óptica Digora e exposta. A densidade óptica (pixels) foi registrada em três diferentes áreas de cada amostra. Os dados foram analisados pelo teste de análise de variância de dois fatores e teste de Tukey (α=0,05). Resultados: Diferenças significantes foram observadas entre todos os materiais e espessuras testadas (P<0,001). O hidrocolóide irreversível e o poliéter apresentaram a menor densidade óptica. O polissulfeto apresentou a maior densidade óptica em todas as condições avaliadas. Conclusão: Há diferença significativa na densidade óptica dos materiais de moldagem avaliados. Alterações na composição são necessárias para facilitar a detecção destes materiais a fim de aumentar a segurança no uso clínico. Palavras-chave: Densidade óptica; radiografia dentária digital; materiais para moldagem odontológicaEDIPUCRS - Editora Universitária da PUCRS2008-09-26info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articlelaboratoryapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/3973Revista Odonto Ciência; Vol. 23 No. 4 (2008); 333 - 337Revista Odonto Ciência; v. 23 n. 4 (2008); 333 - 3371980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/3973/3430Mota, Eduardo GonçalvesRockenbach, Maria Ivete Bolzanda Costa, Nilza PereiraRigo, AngelaCoelho, Carla Renata Radaelliinfo:eu-repo/semantics/openAccess2013-11-18T10:32:04Zoai:ojs.revistaseletronicas.pucrs.br:article/3973Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-18T10:32:04Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false |
dc.title.none.fl_str_mv |
Radiopacity of impression materials using an indirect digital system Radiopacidade de materiais de moldagem usando um sistema digital indireto |
title |
Radiopacity of impression materials using an indirect digital system |
spellingShingle |
Radiopacity of impression materials using an indirect digital system Mota, Eduardo Gonçalves Optical density digital dental radiography dental impression materials radiopacity dental impression materials |
title_short |
Radiopacity of impression materials using an indirect digital system |
title_full |
Radiopacity of impression materials using an indirect digital system |
title_fullStr |
Radiopacity of impression materials using an indirect digital system |
title_full_unstemmed |
Radiopacity of impression materials using an indirect digital system |
title_sort |
Radiopacity of impression materials using an indirect digital system |
author |
Mota, Eduardo Gonçalves |
author_facet |
Mota, Eduardo Gonçalves Rockenbach, Maria Ivete Bolzan da Costa, Nilza Pereira Rigo, Angela Coelho, Carla Renata Radaelli |
author_role |
author |
author2 |
Rockenbach, Maria Ivete Bolzan da Costa, Nilza Pereira Rigo, Angela Coelho, Carla Renata Radaelli |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Mota, Eduardo Gonçalves Rockenbach, Maria Ivete Bolzan da Costa, Nilza Pereira Rigo, Angela Coelho, Carla Renata Radaelli |
dc.subject.por.fl_str_mv |
Optical density digital dental radiography dental impression materials radiopacity dental impression materials |
topic |
Optical density digital dental radiography dental impression materials radiopacity dental impression materials |
description |
Purpose: This in vitro study evaluated the radiopacity of impression materials using an indirect digital system. Methods: Samples of four polyvinyl siloxanes, one polyether, one polysulfide, and one irreversible hydrocolloid were fabricated with 1.0, 1.5, and 3.5mm-thickness. Three samples of different thickness were placed on the Digora optical plate and exposed. The optical density (pixels) was recorded in three areas resulting in a total of 360 measurements. Data were analyzed by 2-way ANOVA and Tukey tests (α=0.05). Results: Significant differences were observed among all materials and thicknesses tested (P<0.001). Irreversible hydrocolloid and polyether showed the lowest optical density. Polysulfide showed the highest optical density under all evaluated conditions. Conclusion: There was a significant difference in optical density for all impression materials tested. Composition changes are suggested to allow radiographic detection and improve safety during clinical use of impression materials. Key words: Optical density; digital dental radiography; dental impression materials |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-09-26 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Peer-reviewed Article laboratory |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/3973 |
url |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/3973 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/3973/3430 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
dc.source.none.fl_str_mv |
Revista Odonto Ciência; Vol. 23 No. 4 (2008); 333 - 337 Revista Odonto Ciência; v. 23 n. 4 (2008); 333 - 337 1980-6523 0102-9460 reponame:Revista odonto ciência (Online) instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) instacron:PUC_RS |
instname_str |
Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
instacron_str |
PUC_RS |
institution |
PUC_RS |
reponame_str |
Revista odonto ciência (Online) |
collection |
Revista odonto ciência (Online) |
repository.name.fl_str_mv |
Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
repository.mail.fl_str_mv |
||odontociencia@pucrs.br |
_version_ |
1754820874370809856 |