In vitro evaluation of dental bleaching effectiveness using hybrid lights activation
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista odonto ciência (Online) |
Texto Completo: | https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5446 |
Resumo: | Purpose: The aim of this in vitro study was to evaluate whether using different types of light activation during the in-office bleaching agent technique increases the effectiveness of the dental bleaching procedure by measuring the color change in teeth. Methods: From 60 extracted bovine incisor teeth, specimen sizes were standardized and dentin was conditioned by immersion in 38% phosphoric acid for 15 s. Following this procedure, the samples were placed in a water bath with ultrasound for 20 min and then immersed in a 25% coffee solution for a two-week period. The dentin was polished with a felt disc and aluminum oxide paste and finally sealed with colorless nail polish. Specimens were randomly divided into five groups, and their original color was measured using the EasyShade (VITA) spectrophotometer. All specimens received three applications of the bleaching agent Opalescence Xtra-Boost (Ultradent) during a period of 15 min each. Group 1 did not receive light activation, Group 2 was activated with a Halogen light (15 min), Group 3 was activated with a blue hybrid LEDs and a laser (15 min), Group 4 was activated with light from a green LED and a laser (15 min) and Group 5 was activated with a red laser (15 min). Tooth color was measured again after performing the various bleaching techniques on all specimens. The resulting data on color variations ΔE, Δa*, Δb* and ΔL*, and the color variations referenced on the Vita Classical scale were subjected to ANOVA, Tukey and Dunn tests (α=5%). Results: The bleaching performance of 38% hydrogen peroxide was affected by the light source used; color reduction was observed for the blue LED and halogen lights, and quantitative assessments of tooth color measured by spectrophotometer and matched to the Vita Classical color scale arrived at similar results in all experimental groups. Conclusions: The type of hybrid lights used interferes in the efficiency of the bleaching agent. |
id |
PUC_RS-22_aae25237da82681f7e9f900d0de464b0 |
---|---|
oai_identifier_str |
oai:ojs.revistaseletronicas.pucrs.br:article/5446 |
network_acronym_str |
PUC_RS-22 |
network_name_str |
Revista odonto ciência (Online) |
repository_id_str |
|
spelling |
In vitro evaluation of dental bleaching effectiveness using hybrid lights activationAvaliação in vitro da eficácia da fotoativação no clareamento dental utilizando a técnica em consultórioBleachinglightLEDclareamento dentalClareamento dentalfotoativaçãodiodos emissores de luzPurpose: The aim of this in vitro study was to evaluate whether using different types of light activation during the in-office bleaching agent technique increases the effectiveness of the dental bleaching procedure by measuring the color change in teeth. Methods: From 60 extracted bovine incisor teeth, specimen sizes were standardized and dentin was conditioned by immersion in 38% phosphoric acid for 15 s. Following this procedure, the samples were placed in a water bath with ultrasound for 20 min and then immersed in a 25% coffee solution for a two-week period. The dentin was polished with a felt disc and aluminum oxide paste and finally sealed with colorless nail polish. Specimens were randomly divided into five groups, and their original color was measured using the EasyShade (VITA) spectrophotometer. All specimens received three applications of the bleaching agent Opalescence Xtra-Boost (Ultradent) during a period of 15 min each. Group 1 did not receive light activation, Group 2 was activated with a Halogen light (15 min), Group 3 was activated with a blue hybrid LEDs and a laser (15 min), Group 4 was activated with light from a green LED and a laser (15 min) and Group 5 was activated with a red laser (15 min). Tooth color was measured again after performing the various bleaching techniques on all specimens. The resulting data on color variations ΔE, Δa*, Δb* and ΔL*, and the color variations referenced on the Vita Classical scale were subjected to ANOVA, Tukey and Dunn tests (α=5%). Results: The bleaching performance of 38% hydrogen peroxide was affected by the light source used; color reduction was observed for the blue LED and halogen lights, and quantitative assessments of tooth color measured by spectrophotometer and matched to the Vita Classical color scale arrived at similar results in all experimental groups. Conclusions: The type of hybrid lights used interferes in the efficiency of the bleaching agent.Objetivo: Avaliar se fontes de luz aumentam a eficácia do peróxido de hidrogênio na técnica de clareamento profissional. Metodologia: Foram empregados 60 dentes incisivos bovinos, com dimensões coronárias e radiculares padronizadas a partir do limite amelo-cementário, sendo descartada a porção lingual. Os corpos-de-prova (cp) foram limpos em ultra-som por 20 min e a dentina condicionada com H3PO4 a 38% por 15s, sendo os (cp) imersos em solução de café solúvel a 25% por duas semanas. A dentina foi impermeabilizada com esmalte e os (cp) divididos em 5 grupos, sendo a cor inicial mensurada através do espectofotômetro-EasyShade (VITA). Todos os (cp) receberam três aplicações por 10 min do gel clareador Opalescence Xtra-Boost (Ultradent)conforme segue: Grupo 1- controle, não recebeu fotoativação, Grupo 2- ativado com luz halôgena, Grupo 3- ativado com LED azul /LASER, Grupo 4- ativado com LED verde /LASER e Grupo 5- ativado com LED vermelho. Após o clareamento foi mensurada a variação de cor ΔE, Δa*, Δb*e ΔL* e as referentes à escala de cor Vita Clássico. Os dados foram submetidos à análise de variância, teste de Tukey e de Dunn (α=5%). Resultados: A diferença geral da cor foi reduzida quando se empregou LED Azul e Luz Halógena, sendo que o desempenho do peróxido de hidrogênio a 38 % foi intensificado dependendo da fonte de luz utilizada. A avaliação quantitativa de cor, obtida por espectrofotômetro e pela escala de cor Vita Clássico, foram coincidentes. Conclusão: O tipo de fonte de luz empregada interfere na eficácia do agente clareador.EDIPUCRS - Editora Universitária da PUCRS2010-02-09info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articleanalise laboratorialapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5446Revista Odonto Ciência; Vol. 25 No. 2 (2010); 159 - 164Revista Odonto Ciência; v. 25 n. 2 (2010); 159 - 1641980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5446/5336Araújo, Rodrigo MaximoTorres, Carlos Rocha GomesAraújo, Maria Amélia Maximoinfo:eu-repo/semantics/openAccess2013-11-11T12:39:32Zoai:ojs.revistaseletronicas.pucrs.br:article/5446Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-11T12:39:32Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false |
dc.title.none.fl_str_mv |
In vitro evaluation of dental bleaching effectiveness using hybrid lights activation Avaliação in vitro da eficácia da fotoativação no clareamento dental utilizando a técnica em consultório |
title |
In vitro evaluation of dental bleaching effectiveness using hybrid lights activation |
spellingShingle |
In vitro evaluation of dental bleaching effectiveness using hybrid lights activation Araújo, Rodrigo Maximo Bleaching light LED clareamento dental Clareamento dental fotoativação diodos emissores de luz |
title_short |
In vitro evaluation of dental bleaching effectiveness using hybrid lights activation |
title_full |
In vitro evaluation of dental bleaching effectiveness using hybrid lights activation |
title_fullStr |
In vitro evaluation of dental bleaching effectiveness using hybrid lights activation |
title_full_unstemmed |
In vitro evaluation of dental bleaching effectiveness using hybrid lights activation |
title_sort |
In vitro evaluation of dental bleaching effectiveness using hybrid lights activation |
author |
Araújo, Rodrigo Maximo |
author_facet |
Araújo, Rodrigo Maximo Torres, Carlos Rocha Gomes Araújo, Maria Amélia Maximo |
author_role |
author |
author2 |
Torres, Carlos Rocha Gomes Araújo, Maria Amélia Maximo |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Araújo, Rodrigo Maximo Torres, Carlos Rocha Gomes Araújo, Maria Amélia Maximo |
dc.subject.por.fl_str_mv |
Bleaching light LED clareamento dental Clareamento dental fotoativação diodos emissores de luz |
topic |
Bleaching light LED clareamento dental Clareamento dental fotoativação diodos emissores de luz |
description |
Purpose: The aim of this in vitro study was to evaluate whether using different types of light activation during the in-office bleaching agent technique increases the effectiveness of the dental bleaching procedure by measuring the color change in teeth. Methods: From 60 extracted bovine incisor teeth, specimen sizes were standardized and dentin was conditioned by immersion in 38% phosphoric acid for 15 s. Following this procedure, the samples were placed in a water bath with ultrasound for 20 min and then immersed in a 25% coffee solution for a two-week period. The dentin was polished with a felt disc and aluminum oxide paste and finally sealed with colorless nail polish. Specimens were randomly divided into five groups, and their original color was measured using the EasyShade (VITA) spectrophotometer. All specimens received three applications of the bleaching agent Opalescence Xtra-Boost (Ultradent) during a period of 15 min each. Group 1 did not receive light activation, Group 2 was activated with a Halogen light (15 min), Group 3 was activated with a blue hybrid LEDs and a laser (15 min), Group 4 was activated with light from a green LED and a laser (15 min) and Group 5 was activated with a red laser (15 min). Tooth color was measured again after performing the various bleaching techniques on all specimens. The resulting data on color variations ΔE, Δa*, Δb* and ΔL*, and the color variations referenced on the Vita Classical scale were subjected to ANOVA, Tukey and Dunn tests (α=5%). Results: The bleaching performance of 38% hydrogen peroxide was affected by the light source used; color reduction was observed for the blue LED and halogen lights, and quantitative assessments of tooth color measured by spectrophotometer and matched to the Vita Classical color scale arrived at similar results in all experimental groups. Conclusions: The type of hybrid lights used interferes in the efficiency of the bleaching agent. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-02-09 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Peer-reviewed Article analise laboratorial |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5446 |
url |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5446 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5446/5336 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
dc.source.none.fl_str_mv |
Revista Odonto Ciência; Vol. 25 No. 2 (2010); 159 - 164 Revista Odonto Ciência; v. 25 n. 2 (2010); 159 - 164 1980-6523 0102-9460 reponame:Revista odonto ciência (Online) instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) instacron:PUC_RS |
instname_str |
Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
instacron_str |
PUC_RS |
institution |
PUC_RS |
reponame_str |
Revista odonto ciência (Online) |
collection |
Revista odonto ciência (Online) |
repository.name.fl_str_mv |
Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
repository.mail.fl_str_mv |
||odontociencia@pucrs.br |
_version_ |
1754820874935992320 |